The progress of contemporary cardiovascular therapy has led to improved survival in patients with myocardial disease. However, the development of heart failure (HF) represents a common clinical challenge, regardless of the underlying myocardial pathology, due to the severely impaired quality of life and increased mortality comparable with malignant neoplasms. Left ventricular ejection fraction (LVEF) is the main index of systolic function and a key predictor of mortality among HF patients, hence its improvement represents the main indicator of response to instituted therapy. The introduction of complex pharmacotherapy for HF, increased availability of cardiac-implantable electronic devices and advances in the management of secondary causes of HF, including arrhythmia-induced cardiomyopathy, have led to significant increase in the proportion of patients with prominent improvement or even normalization of LVEF, paving the way for the identification of a new subgroup of HF with an improved ejection fraction (HFimpEF). Accumulating data has indicated that these patients share far better long-term prognoses than patients with stable or worsening LVEF. Due to diverse HF aetiology, the prevalence of HFimpEF ranges from roughly 10 to 40%, while the search for reliable predictors and genetic associations corresponding with this clinical presentation is under way. As contemporary guidelines focus mainly on the management of HF patients with clearly defined LVEF, the present review aimed to characterize the definition, epidemiology, predictors, clinical significance and principles of therapy of patients with HFimpEF.
Heart failure (HF) remains a disease with a poor prognosis. Telemonitoring is a medical service aimed at remote monitoring of patients. The study aimed to identify the clinical relevance of non-invasive telemonitoring devices in HF patients. Sixty patients aged 66.1 (11) years, with left ventricular ejection fraction (LVEF) 26.3 (6.8)% underwent cardiac resynchronization therapy (CRT) implantation. They were randomly allocated to the control (standard medical care) or study (standard medical care + telemonitoring device) groups. During the follow-up (24 months), the patients in the study group provided body mass and blood pressure, along with electrocardiogram on a daily basis. The data were transferred to themonitoring center and consulted with a cardiologist. Transthoracic echocardiography and a 6-minute walk test were performed before and 24 months after CRT implantation. During the two-year observation, the composite endpoint (death or HF hospitalization) occurred in 21 patients, more often in the control group (46.8% vs. 21.4%; P = 0.026). Inunivariate analysis: the use of telemetry (hazard ratio [HR], 0.2; 95% confidence interval [CI], 0.07-0.7; P=0.004), thepresence of coronary heart disease (HR, 41.4; 95% CI, 3.1-567.7; P=0.005), hypertension (HR, 0.24; 95% CI, 0.07-0.90; P = 0.035), and patient's body mass (HR, 0.36; 95% CI, 0.14-0.92; P = 0.03) were related to the occurrence of the composite endpoint. The use of a telemonitoring device in CRT recipients improved theprognosis in2-year observation and contributed to the reduction of HF hospitalization.
Background: Coronavirus disease 2019 (COVID-19) pandemic disorganised healthcare systems and has caused a reduction in the number of hospitalizations and procedures. Cardiac implantable electronic device (CIED) procedure rates and clinical characteristics of their recipients were compared in corresponding weeks of 2019 and 2020 were analyzed. Methods: The database of the National Health Fund (NHF) in Poland was retrospectively analyzed. 3206 patients who underwent CIED implantation in the Silesia — a region in Southern Poland comprising an adult population of 3.8 million between 12th and 31st week of 2020. Patients were classified into groups: the recipient of an implantable cardioverter-defibrillator or cardiac resynchronization therapy group (ICD/CRT)or pacemaker group (PM). Results: During the pandemic a reduction of 39.38% of implantations was observed compared to the same period in 2019 (1210 vs. 1996 patients) and had impacted both groups. Two phases lasting 10 weeks each could be distinguished: total lockdown (maximal reduction) and the recovery phase with growing numbers of procedures. Patient baseline characteristics (sex, age, comorbidities) who were implanted during the COVID-19 pandemic did not differ from the 2019 period. The rate of peri-procedural mortality was also similar. Conclusions: During COVID-19 pandemic period a reduction in CIED implantations of all types was observed. Despite the decreased number of performed CIED implants, no differences in baseline patient characteristics were observed. Background: Coronavirus disease 2019 (COVID-19) pandemic disorganised healthcare systems and has caused a reduction in the number of hospitalizations and procedures. Cardiac implantable electronic device (CIED) procedure rates and clinical characteristics of their recipients were compared in corresponding weeks of 2019 and 2020 were analyzed. Methods: The database of the National Health Fund (NHF) in Poland was retrospectively analyzed. 3206 patients who underwent CIED implantation in the Silesia — a region in Southern Poland comprising an adult population of 3.8 million between 12th and 31st week of 2020. Patients were classified into groups: the recipient of an implantable cardioverter-defibrillator or cardiac resynchronization therapy group (ICD/CRT)or pacemaker group (PM). Results: During the pandemic a reduction of 39.38% of implantations was observed compared to the same period in 2019 (1210 vs. 1996 patients) and had impacted both groups. Two phases lasting 10 weeks each could be distinguished: total lockdown (maximal reduction) and the recovery phase with growing numbers of procedures. Patient baseline characteristics (sex, age, comorbidities) who were implanted during the COVID-19 pandemic did not differ from the 2019 period. The rate of peri-procedural mortality was also similar. Conclusions: During COVID-19 pandemic period a reduction in CIED implantations of all types was observed. Despite the decreased number of performed CIED implants, no differences in baseline patient characteristics were observed.
Introduction : The aim of our study was to determine the risk factors for electrical storm (ES) and to assess the impact of ES on the long-term prognosis in patients after myocardial infarction (MI) with an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac...
14 June 2016 in International Journal of Cardiology
The aim of the study was: (1) to verify the hypothesis that left ventricular global longitudinal strain (LVGLS) may be of additive prognostic value in prediction CRT response and (2) to obtain such a LVGLS value that in the best optimal way enables to characterize potential CRT responders. Forty-nine HF patients (age 66.5 ± 10 years, LVEF 24.9 ± 6.4%, LBBB 71.4%, 57.1% ischemic aetiology of HF) underwent CRT implantation. Transthoracic echocardiography was performed prior to and 15 ± 7 months after CRT implantation. Speckle-tracking echocardiography was performed to assess longitudinal left ventricular function as LVGLS. The response to CRT was defined as a ≥ 15% reduction in the left ventricular end-systolic volume (∆LVESV). Thirty-six (73.5%) patients responded to CRT. There was no linear correlation between baseline LVGLS and ∆LVESV (r = 0.09;p = 0.56). The patients were divided according to the percentile of baseline LVGLS: above 80th percentile; between 80 and 40th percentile; below 40th percentile. Two peripheral groups (above 80th and below 40th percentile) formed “peripheral LVGLS” and the middle group was called “mid-range LVGLS”. The absolute LVGLS cutoff values were − 6.07% (40th percentile) and − 8.67% (80th percentile). For the group of 20 (40.8%) “mid-range LVGLS” patients mean ΔLVESV was 33.3 ± 16.9% while for “peripheral LVGLS” ΔLVESV was 16.2 ± 18.8% (p < 0.001). Among non-ischemic HF etiology, all “mid-range LVGLS” patients (100%) responded positively to CRT (in “peripheral LVGLS”—55% responders;p = 0.015). Baseline LVGLS may have a potential prognostic value in prediction CRT response with relationship of inverted J-shaped pattern. “Mid-range LVGLS” values should help to select CRT responders, especially in non-ischemic HF etiology patients.