The recorded electroencephalography (EEG) signals are usually contaminated by electrooculography (EOG) artifacts. In this paper, by using independent component analysis (ICA) and multivariate empirical mode decomposition (MEMD), the ICA-based MEMD method was proposed to remove EOG artifacts (EOAs) from multichannel EEG signals. First, the EEG signals were decomposed by the MEMD into multiple multivariate intrinsic mode functions (MIMFs). The EOG-related components were then extracted by reconstructing the MIMFs corresponding to EOAs. After performing the ICA of EOG-related signals, the EOG-linked independent components were distinguished and rejected. Finally, the clean EEG signals were reconstructed by implementing the inverse transform of ICA and MEMD. The results of simulated and real data suggested that the proposed method could successfully eliminate EOAs from EEG signals and preserve useful EEG information with little loss. By comparing with other existing techniques, the proposed method achieved much improvement in terms of the increase of signal-to-noise and the decrease of mean square error after removing EOAs.
Automatic seizure prediction promotes the development of closed-loop treatment system on intractable epilepsy. In this study, by considering the specific information exchange between EEG channels from the perspective of whole brain activities, the convolution neural network (CNN) and the directed transfer function (DTF) were merged to present a novel method for patient-specific seizure prediction. Firstly, the intracranial electroencephalogram (iEEG) signals were segmented and the information flow features of iEEG signals were calculated by using the DTF algorithm. Then, these features were reconstructed as the channel-frequency maps according to channel pairs and the frequency of information flow. Finally, these maps were fed into the CNN model and the outputs were post-processed by the moving average approach to predict the epileptic seizures. By the evaluation of cross-validation method, the proposed algorithm achieved the averaged sensitivity of 90.8%, the averaged false prediction rate of 0.08 per hour. Compared to the random predictor and other existing algorithms tested on the Freiburg EEG dataset, our proposed method achieved better performance for seizure prediction in all patients. These results demonstrated that the proposed algorithm could provide an robust seizure prediction solution by using deep learning to capture the brain network changes of iEEG signals from epileptic patients.
27 February 2018 in IEEE Transactions on Biomedical Engineering
Goal: The accurate automatic detection of epileptic seizures is very important in long-term electroencephalogram (EEG) recordings. In this study, the wavelet decomposition and the directed transfer function (DTF) algorithm were combined to present a novel wavelet-based directed transfer function (WDTF) method for the patient-specific seizure detection. Methods: First, five subbands were extracted from 19-channel EEG signals by using wavelet decomposition in a sliding window. Second, the information flow characteristics of five subbands and full frequency band of EEG signals were calculated by the DTF method. The intensity of the outflow information was then used to reduce the feature dimensionality. Finally, all features were combined to identify interictal and ictal EEG segments by the support vector machine classifier. Results: By using fivefold cross validation, the proposed method had achieved excellent performance with the average accuracy of 99.4%, the average selectivity of 91.1%, the average sensitivity of 92.1%, the average specificity of 99.5%, and the average detection rate of 95.8%. Conclusion: The WDTF method is able to enhance seizure detection results in long-term EEG recordings of focal epilepsy patients. Significance: This study may lead to the development of seizure detection system with high performance, thus reducing the workload of epileptologists and facilitating to take corresponding steps promptly after the seizure onset. The high-frequency activity in the epilepsy brain may be of great importance for investigating the pathological mechanism and treatment of seizure.
Electroencephalogram (EEG) microstate analysis is a promising and effective spatio-temporal method that can segment signals into several quasi-stable classes, providing a great opportunity to investigate short-range and long-range neural dynamics. However, there are still many controversies in terms of reproducibility and reliability when selecting different parameters or datatypes. In this study, five electrode configurations (91, 64, 32, 19, and 8 channels) were used to measure the reliability of microstate analysis at different electrode densities during propofol-induced sedation. First, the microstate topography and parameters at five different electrode densities were compared in the baseline (BS) condition and the moderate sedation (MD) condition, respectively. The intraclass correlation coefficient (ICC) and coefficient of variation (CV) were introduced to quantify the consistency of the microstate parameters. Second, statistical analysis and classification between BS and MD were performed to determine whether the microstate differences between different conditions remained stable at different electrode densities, and ICC was also calculated between the different conditions to measure the consistency of the results in a single condition. The results showed that in both the BS or MD condition, respectively, there were few significant differences in the microstate parameters among the 91-, 64-, and 32-channel configurations, with most of the differences observed between the 19- or 8-channel configurations and the other configurations. The ICC and CV data also showed that the consistency among the 91-, 64-, and 32-channel configurations was better than that among all five electrode configurations after including the 19- and 8-channel configurations. Furthermore, the significant differences between the conditions in the 91-channel configuration remained stable at the 64- and 32-channel resolutions, but disappeared at the 19- and 8-channel resolutions. In addition, the classification and ICC results showed that the microstate analysis became unreliable with fewer than 20 electrodes. The findings of this study support the hypothesis that microstate analysis of different brain states is more reliable with higher electrode densities; the use of a small number of channels is not recommended.