Tasbiraha Athaya

Mrs. Tasbiraha Athaya

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TATasbiraha Athaya
Tasbiraha Athaya
SCSunwoong Choi
Sunwoong Choi
Blood pressure (BP) monitoring has significant importance in the treatment of hypertension and different cardiovascular health diseases. As photoplethysmogram (PPG) signals can be recorded non-invasively, research has been highly conducted to measure BP using PPG recently. In this paper, we propose a U-net deep learning architecture that uses fingertip PPG signal as input to estimate arterial BP (ABP) waveform non-invasively. From this waveform, we have also measured systolic BP (SBP), diastolic BP (DBP), and mean arterial pressure (MAP). The proposed method was evaluated on a subset of 100 subjects from two publicly available databases: MIMIC and MIMIC-III. The predicted ABP waveforms correlated highly with the reference waveforms and we have obtained an average Pearson’s correlation coefficient of 0.993. The mean absolute error is 3.68 ± 4.42 mmHg for SBP, 1.97 ± 2.92 mmHg for DBP, and 2.17 ± 3.06 mmHg for MAP which satisfy the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standard and obtain grade A according to the British Hypertension Society (BHS) standard. The results show that the proposed method is an efficient process to estimate ABP waveform directly using fingertip PPG.

31 August 2023 in Briefings in Bioinformatics
Verified
Journal Article
Open access
PDF file
TATasbiraha Athaya
Tasbiraha Athaya
RRRony Chowdhury Ripan
Rony Chowdhury Ripan
XLXiaoman Li
Xiaoman Li
HHHaiyan Hu
Haiyan Hu
Integrating single-cell multi-omics data is a challenging task that has led to new insights into complex cellular systems. Various computational methods have been proposed to effectively integrate these rapidly accumulating datasets, including deep learning. However, despite the proven success of deep learning in integrating multi-omics data and its better performance over classical computational methods, there has been no systematic study of its application to single-cell multi-omics data integration. To fill this gap, we conducted a literature review to explore the use of multimodal deep learning techniques in single-cell multi-omics data integration, taking into account recent studies from multiple perspectives. Specifically, we first summarized different modalities found in single-cell multi-omics data. We then reviewed current deep learning techniques for processing multimodal data and categorized deep learning-based integration methods for single-cell multi-omics data according to data modality, deep learning architecture, fusion strategy, key tasks and downstream analysis. Finally, we provided insights into using these deep learning models to integrate multi-omics data and better understand single-cell biological mechanisms.

23 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TATasbiraha Athaya
Tasbiraha Athaya
SCSunwoong Choi
Sunwoong Choi
Accurate estimation of blood pressure (BP) waveforms is critical for ensuring the safety and proper care of patients in intensive care units (ICUs) and for intraoperative hemodynamic monitoring. Normal cuff-based BP measurements can only provide systolic blood pressure (SBP) and diastolic blood pressure (DBP). Alternatively, the BP waveform can be used to estimate a variety of other physiological parameters and provides additional information about the patient’s health. As a result, various techniques are being proposed for accurately estimating the BP waveforms. The purpose of this review is to summarize the current state of knowledge regarding the BP waveform, three methodologies (pressure-based, ultrasound-based, and deep-learning-based) used in noninvasive BP waveform estimation research and the feasibility of employing these strategies at home as well as in ICUs. Additionally, this article will discuss the physical concepts underlying both invasive and noninvasive BP waveform measurements. We will review historical BP waveform measurements, standard clinical procedures, and more recent innovations in noninvasive BP waveform monitoring. Although the technique has not been validated, it is expected that precise, noninvasive BP waveform estimation will be available in the near future due to its enormous potential.

18 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
TATasbiraha Athaya
Tasbiraha Athaya
SCSunwoong Choi
Sunwoong Choi
Measuring continuous blood pressure (BP) in real time by using a mobile health (mHealth) application would open a new door in the advancement of the healthcare system. This study aimed to propose a real-time method and system for measuring BP without using a cuff from a digital artery. An energy-efficient real-time smartphone-application-friendly one-dimensional (1D) Squeeze U-net model is proposed to estimate systolic and diastolic BP values, using only raw photoplethysmogram (PPG) signal. The proposed real-time cuffless BP prediction method was assessed for accuracy, reliability, and potential usefulness in the hypertensive assessment of 100 individuals in two publicly available datasets: Multiparameter Intelligent Monitoring in Intensive Care (MIMIC-I) and Medical Information Mart for Intensive Care (MIMIC-III) waveform database. The proposed model was used to build an android application to measure BP at home. This proposed deep-learning model performs best in terms of systolic BP, diastolic BP, and mean arterial pressure, with a mean absolute error of 4.42, 2.25, and 2.56 mmHg and standard deviation of 4.78, 2.98, and 3.21 mmHg, respectively. The results meet the grade A performance requirements of the British Hypertension Society and satisfy the AAMI error range. The result suggests that only using a short-time PPG signal is sufficient to obtain accurate BP measurements in real time. It is a novel approach for real-time cuffless BP estimation by implementing an mHealth application and can measure BP at home and assess hypertension.

1 January 2021 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
TATasbiraha Athaya
Tasbiraha Athaya
SCSunwoong Choi
Sunwoong Choi
A photoplethysmography method has recently been widely used to noninvasively measure blood volume changes during a cardiac cycle. Photoplethysmogram (PPG) signals are sensitive to artifacts that negatively impact the accuracy of many important measurements. In this paper, we propose an efficient system for detecting PPG signal artifacts acquired from a fingertip in the public healthcare database named Multiparameter Intelligent Monitoring in Intensive Care (MIMIC) by using 11 features as the input of the random forest algorithm and classified the signals into two classes: acceptable and anomalous. A real‐time algorithm is proposed to identify artifacts by using the method. The efficient Fisher score feature selection algorithm was used to order and select 11 relevant features from 19 available features that represented the PPG signal very effectively. Six machine learning algorithms (random forest, decision tree, Gaussian naïve Bayes, linear support vector machine, artificial neural network, and probabilistic neural network) were applied with the extracted features, and their classification accuracy was measured. Among them, the random forest had the best performance using only 11 out of 19 features with an accuracy of 85.68%. Our proposed method also achieved good sensitivity and specificity value of 86.57% and 85.09%, respectively. The proposed real‐time algorithm can be an easy and convenient way for real‐time PPG signal artifact detection using smartphones and wearable devices.

8 May 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
RRRony Chowdhury Ripan
Rony Chowdhury Ripan
TATasbiraha Athaya
Tasbiraha Athaya
XLXiaoman Li
Xiaoman Li
HHHaiyan Hu
Haiyan Hu
Understanding the activity of miRNA in individual cells presents a challenge due to the limitations of single-cell technologies in capturing miRNAs. To tackle this obstacle, we introduce two deep learning models: Cross-Modality (CM) and Single-Modality (SM). These models utilize encoder-decoder architectures to predict miRNA expression at the bulk and single-cell levels from mRNA data. We compared CM and SM with a state-of-the-art approach, miRSCAPE, using both bulk and single-cell datasets. We found that both CM and SM outperformed miRSCAPE in terms of accuracy. We also observed that integrating miRNA target information led to a significant enhancement in performance compared to using all genes. These models offer valuable tools for predicting miRNA expression from single-cell mRNA data.