Most 3-D magnetic particle imaging (MPI) scanners currently use permanent magnets to create the strong gradient field required for high resolution MPI. However, using permanent magnets limits the field of view (FOV) due to the large amount of energy required to move the field free point (FFP) from the center of the scanner. To address this issue, an alternative approach called “Traveling Wave MPI” is here presented. This approach employs a novel gradient system, the dynamic linear gradient array, to cover a large FOV while dynamically creating a strong magnetic gradient. The proposed design also enables the use of a so-called line-scanning mode, which simplifies the FFP trajectory to a linear path through the 3-D volume. This results in simplified mathematics, which facilitates the image reconstruction.
4 June 2014 in IEEE Transactions on Medical Imaging
While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superpara magnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co-registration has been hampered by the need to reposition the sample in both systems as similarly as possible. This paper presents a bimodal MPI-MRI-tomograph that combines both modalities in a single system. MPI and MRI images can thus be acquired without moving the sample or replacing any parts in the setup. The images acquired with the presented setup show excellent agreement between the localization of the nano particles in MPI and the MRI background data. A combination of two highly complementary imaging modalities has been achieved.
Magnetic particle imaging (MPI) is a non-invasive imaging modality for direct detection of superparamagnetic iron-oxide nanoparticles based on the nonlinear magnetization response of magnetic materials to alternating magnetic fields. This highly sensitive and rapid method allows both a quantitative and a qualitative analysis of the measured signal. Since the first publication of MPI in 2005 several different scanner concepts have been presented and in 2009 the first in vivo imaging results of a beating mouse heart were shown. However, since the field of view (FOV) of the first MPI-scanner only covers a small region several approaches and hardware enhancements were presented to overcome this issue and could increase the FOV on cost of acquisition speed. In 2014 an alternative scanner concept, the traveling wave MPI (TWMPI), was presented, which allows scanning an entire mouse-sized volume at once. In this paper the first in vivo imaging results using the TWMPI system are presented. By optimizing the trajectory the temporal resolution is sufficiently high to resolve the dynamic of a beating mouse heart.
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
This work analyzes the ability of split-ring metamaterial slabs with zero/high permeability to reject/confine the radiofrequency magnetic field in magnetic resonance imaging systems. Split-ring slabs are designed and fabricated to work in a 1.5 T system. Nonlinear elements consisting of pairs of crossed diodes are inserted in the split-rings, so that the slab permeability can be switched between a value close to unity when interacting with the strong field of the transmitting coil, and zero or high values when interacting with the weak field produced by protons in tissue. Experiments are shown where these slabs locally increase the signal-to-noise-ratio.
Magnetic nanoparticles (MNPs) have been adapted for many applications, e.g., bioassays for the detection of biomarkers such as antibodies, by controlled engineering of specific surface properties. Specific measurement of such binding states is of high interest but currently limited to highly sensitive techniques such as ELISA or flow cytometry, which are relatively inflexible, difficult to handle, expensive and time-consuming. Here we report a method named COMPASS (Critical-Offset-Magnetic-Particle-SpectroScopy), which is based on a critical offset magnetic field, enabling sensitive detection to minimal changes in mobility of MNP ensembles, e.g., resulting from SARS-CoV-2 antibodies binding to the S antigen on the surface of functionalized MNPs. With a sensitivity of 0.33 fmole/50 µl (≙7 pM) for SARS-CoV-2-S1 antibodies, measured with a low-cost portable COMPASS device, the proposed technique is competitive with respect to sensitivity while providing flexibility, robustness, and a measurement time of seconds per sample. In addition, initial results with blood serum demonstrate high specificity.