Ali C. Kheirabadi

Ali C. Kheirabadi


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AKAli C. Kheirabadi
Ali C. Kheirabadi
DGDominic Groulx
Dominic Groulx

1 August 2021 in Ocean Engineering
Verified
Journal Article
Closed access
AKAli C. Kheirabadi
Ali C. Kheirabadi
RNRyozo Nagamune
Ryozo Nagamune

22 March 2022 in Renewable Energy
Verified
Journal Article
Closed access
GFGabrielle Froese
Gabrielle Froese
SKShan Yu Ku
Shan Yu Ku
AKAli C. Kheirabadi
Ali C. Kheirabadi
RNRyozo Nagamune
Ryozo Nagamune

1 January 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AKAli C. Kheirabadi
Ali C. Kheirabadi
DGDominic Groulx
Dominic Groulx

13 May 2019 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
AKAli C. Kheirabadi
Ali C. Kheirabadi
DGDominic Groulx
Dominic Groulx
This study compares two numerical strategies for modeling flow and heat transfer through mini- and micro- channel heatsinks, the unit cell approximation and the full 3D model, with the objective of validating the former approach. Conjugate heat transfer and laminar flow through a 2×2 cm2 copper-water heatsink are modelled using the finite element package COMSOL Multiphysics 5.0. Parametric studies showed that as the heatsink channels widths were reduced, and the total number of channels increased, temperature and pressure predictions from both models converged to similar values. Relative differences as low as 5.4 and 1.6 % were attained at a channel width of 0.25 mm for maximum wall temperature and channel pressure drop, respectively. Due to its computational efficiency and tendency to conservatively overpredict temperatures relative to the full 3D method, the unit cell approximation is recommended for parametric design of heatsinks with channels widths smaller than 0.5 mm. The unit cell method is then used to design an optimal heatsink for server liquid cooling applications. The heatsink has been fabricated and tested experimentally and its thermal performance is compared with numerical predictions. The unit cell method underestimated the maximum wall temperature relative to experimental results by 3.0 to 14.5 % as the flowrate rose from 0.3 to 1.5 gal/min (1.1 to 5.7 L/min).

20 October 2020 in arXiv
Verified
Preprint
Open access
PDF file
AKAli C. Kheirabadi
Ali C. Kheirabadi
RNRyozo Nagamune
Ryozo Nagamune
This paper introduces a novel concept for addressing non-convexity in the cost functions of distributed economic model predictive control (DEMPC) systems. Specifically, the proposed algorithm enables agents to self-organize into a hierarchy which determines the order in which control decisions are made. This concept is based on the formation of social hierarchies in nature. An additional feature of the algorithm is that it does not require stationary set-points that are known a priori. Rather, agents negotiate these targets in a truly distributed and scalable manner. Upon providing a detailed description of the algorithm, guarantees of convergence, recursive feasibility, and bounded closed-loop stability are also provided. Finally, the proposed algorithm is compared against a basic parallel distributed economic model predictive controller using an academic numerical example.