Cattareeya Suwanasri

Prof. Dr. Cattareeya Suwanasri

King Mongkut's University of Technology North Bangkok, Bangkok, Thailand

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Nitchamon PoonnoyNitchamon Poonnoy
Nitchamon Poonnoy
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
TSThanapong Suwanasri
Thanapong Suwanasri
This research focuses on problem identification due to faults in power transformers during operation by using dissolved gas analysis such as key gas, IEC ratio, Duval triangle techniques, and fuzzy logic approaches. Then, the condition of the power transformer is evaluated in terms of the percentage of failure index and internal fault determination. Fuzzy logic with the key gas approach was used to calculate the failure index and identify problems inside the power transformer. At the same time, the IEC three-gas ratio and Duval triangle are subsequently applied to confirm the problems in different failure types covering all possibilities inside the power transformer. After that, the fuzzy logic system was applied and validated with DGA results of 244 transformers as reference cases with satisfactory accuracy. Two transformers were evaluated and practically confirmed by the investigation results of an un-tanked power transformer. Finally, the DGA results of a total of 224 transformers were further evaluated by the fuzzy logic system. This fuzzy logic is a smart, accurate tool for automatically identifying faults occurring within transformers. Finally, the recommendation of maintenance strategy and time interval is proposed for effective planning to minimize the catastrophic damage, which could occur with the power transformer and its network.

12 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
SSSurapol Saribut
Surapol Saribut
TSThanapong Suwanasri
Thanapong Suwanasri
RPRattanakorn Phadungthin
Rattanakorn Phadungthin
In this paper, we apply the Failure Modes, Effects, and Criticality Analysis (FMECA) approach to the criticality and risk analysis of the efficiency, safety/reliability, environment, and financial criteria of the high voltage transmission line. In the efficiency analysis, the weighting-scoring method and analytical hierarchy process are applied to obtain the line renovation index, which is interpreted as efficiency severity. The safety/reliability severity relates to the system impacts are caused by failure of the equipment and the system. The environmental severity takes social impacts and pollution into consideration. The financial severity involves the cost of spare parts and maintenance costs, which are interpreted as the financial severity of the lines. Twenty practical transmission lines in Thailand with actual data for 115, 230, and 500 kV were studied. The transmission line components are divided into eight components including the conductor, conductor accessories, insulator, steel structure, foundation, lightning protection system, tower accessories, and right-of-way. The severity and criticality of the components and transmission lines are analyzed and plotted in criticality matrices based on four criteria. This criticality matrix is presented at four different levels including very low, low, medium, and high risk, as represented by four color bands: green, yellow, orange, and red, respectively. The results show that three 115 kV lines are the first priority for short-term reconstruction planning because of their unacceptable condition and high risk in terms of safety/reliability and financing. Recommendations for maintenance strategy and risk mitigation are proposed for the utility according to the utility’s actual criticality. Ultimately, maintenance planning of the transmission system can be effectively managed with higher reliability, a lower risk of failure, and a lower cost of maintenance.

12 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
NPNattapon Panmala
Nattapon Panmala
TSThanapong Suwanasri
Thanapong Suwanasri
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
This paper proposes a comprehensive procedure to assess the condition of gas insulated switchgear (GIS) equipment by using the conventional weight and score method and introducing a conditional factor to improve the accuracy of the health index evaluation. Generally, the inspection and testing of GIS components are conducted according to manufacturer recommendations and guidelines in the international standards. However, this raw data has not been simplified and systematically processed for condition assessment. The score and weight technique are applied to transform the physical condition according to visible and measurable aging to numerical values in terms of component and bay health index values. The accuracy of the obtained health index has been improved by a conditional factor, which considers invisible aging factors, such as age, number of switching operations, degree of satisfactory operation, obsolescence, and adequacy of the interrupting rating. Here, a condition evaluation procedure has been developed and compared with the fuzzy logic method and the health index dominant score technique with satisfactory results. Subsequently, the proposed procedure has been developed as web application software to evaluate 175 bays of GIS in both 115 and 230 kV networks of an independent power producer supplying electricity of 3094 MW to a large industrial estate in Thailand. Eight GIS bays showed moderate or poor condition and the proper actions were assigned to prevent their failure. The software is in use in practice as a decision support tool to effectively manage the maintenance tasks and to improve supply reliability.

13 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
Tanachai SomsakTanachai Somsak
Tanachai Somsak
TSThanapong Suwanasri
Thanapong Suwanasri
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
In this paper, a modeling method for estimating the remaining useful life (RUL) of aged underground cable systems is proposed that uses statistical health index (HI) and operating factor (OF) data of retired systems. The HI is an indicator which identifies the condition of an underground cable system and its components and is calculated from testing and inspection results. The OF takes actual operating conditions and technical data from the system into consideration. Both factors are then combined to determine the overall health index (OHI) of each system. For RUL estimation of underground cable systems, normal distribution and Weibull distribution analyses are first applied to determine a health index curve and an aging line. The relationship between these two curves gives an estimate of the system’s apparent age. The RUL of the system is then calculated in terms of the difference between its apparent age and its actual chronological age. In this study, thirteen retired systems and ten operating systems were evaluated and analyzed, and accurate results were obtained. Using the methods described here, the apparent age and the RUL of underground cable systems can be accurately estimated. Finally, a maintenance strategy for underground cable systems is recommended, which promises more efficient maintenance and greater cost-effectiveness in the management of underground cable systems.

3 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Tanachai SomsakTanachai Somsak
Tanachai Somsak
TSThanapong Suwanasri
Thanapong Suwanasri
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
In this paper, a lifetime estimation method for underground cable systems is proposed by combining a health index (HI) and conditional factor (CF). The underground cable system consists of underground cable, joint, termination, manhole, and duct bank. The HI is an indicator to indicate the actual condition of underground cable components and systems whereas the CF is used to indicate different operating stresses of the system under different operating conditions such as percentage loading, electrical stresses, laying structure, environment, etc. The actual technical data as well as historical operating and testing records are applied. The weighting and scoring method with the analytical hierarchy process are used to classify an importance of underground cable components, testing methods, and criteria used in the HI and CF calculation. The annual calculated HIs are plotted to investigate the lifetime trending curve by using a polynomial function. The degradation curve based on calculated CF is estimated by using the Weibull distribution function. Finally, the remaining life of the underground cable system is determined by matching the lifetime trending curve with the degradation curve. Ten practical underground cable systems supplying power in a high voltage power delivery system are evaluated with effective results. The lifetime of the underground cable system can be successfully estimated.

22 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
WLWaraporn Luejai
Waraporn Luejai
TSThanapong Suwanasri
Thanapong Suwanasri
Cattareeya SuwanasriCattareeya Suwanasri
Cattareeya Suwanasri
In this paper, a D-distance risk factor was proposed to prioritize high-voltage transmission lines from high to low risk in transmission line maintenance and renovation management. Various conditions and importance assessment criteria together with the weighting and scoring method were proposed to calculate both the renovation and importance indices of transmission lines. The scores of different test methods and visual inspection were differentiated from zero to five as end-of-life to very good condition to evaluate the condition of the line and its components. Additionally, the scores of different importance criteria were modified to assess the line importance from low to high importance. Moreover, the analytic hierarchy process was applied to determine the important weight of all test methods and importance criteria, which were evaluated by utility experts. The renovation and importance indices were combined in a risk matrix to finally determine the risk of the line by using the D-distance technique. Later, the risk of every transmission line was plotted in a risk matrix to prioritize and manage maintenance tasks. Finally, a maintenance cost was analyzed by applying the D-distance risk factor and compared with the replacement cost of a new transmission line for maintenance planning and cost minimization. Twenty out of 115, 230 and 500 kV transmission lines fleet in Thailand were practically analyzed with actual data. The results were realistic to feasibly implement in a transmission system for sustainable management.