Philipp Warnke

Dr. Philipp Warnke


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPhilipp Warnke
Philipp Warnke
HFHagen Frickmann
Hagen Frickmann
POPeter Ottl
Peter Ottl
APAndreas Podbielski
Andreas Podbielski
Swab-based nasal screening is commonly used to identify asymptomatic carriage of Staphylococcus aureus in patients. Bacterial detection depends on the uptake and release capacities of the swabs and on the swabbing technique itself. This study investigates the performance of different swab-types in nasal MRSA-screening by utilizing a unique artificial nose model to provide realistic and standardized screening conditions. An anatomically correct artificial nose model was inoculated with a numerically defined mixture of MRSA and Staphylococcus epidermidis bacteria at quantities of 4×102 and 8×102 colony forming units (CFU), respectively. Five swab-types were tested following a strict protocol. Bacterial recovery was measured for direct plating and after elution into Amies medium by standard viable count techniques. Mean recovered bacteria quantities varied between 209 and 0 CFU for MRSA, and 365 and 0 CFU for S. epidermidis, resulting swab-type-dependent MRSA-screening-sensitivities ranged between 0 and 100%. Swabs with nylon flocked tips or cellular foam tips performed significantly better compared to conventional rayon swabs referring to the recovered bacterial yield (p<0.001). Best results were obtained by using a flocked swab in combination with Amies preservation medium. Within the range of the utilized bacterial concentrations, recovery ratios for the particular swab-types were independent of the bacterial species. This study combines a realistic model of a human nose with standardized laboratory conditions to analyze swab-performance in MRSA-screening situations. Therefore, influences by inter-individual anatomical differences as well as diverse colonization densities in patients could be excluded. Recovery rates vary significantly between different swab-types. The choice of the swab has a great impact on the laboratory result. In fact, the swab-type contributes significantly to true positive or false negative detection of nasal MRSA carriage. These findings should be considered when screening a patient.

10 July 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPhilipp Warnke
Philipp Warnke
LWLiesa Warning
Liesa Warning
APAndreas Podbielski
Andreas Podbielski
Swabs are widely used to collect samples for microbiological analyses from various clinical settings. They vary by material, size, and structure of the tip. This study investigates the uptake and release capacities for liquid and bacteria. Five swabs were analyzed for their uptake and release capacities of Staphylococcus aureus and Staphylococcus epidermidis suspensions. Two approaches were investigated providing volume-restricted and unrestricted amounts of bacterial suspensions to mimic various clinical situations. Volume and bacterial uptake and release were measured in milligrams and by counting colony forming units (CFU), respectively. Volume uptake and release in the unrestricted setting varied highly significant between 239.6 mg and 88.7 mg (p<0.001) and between 65.2 mg and 2.2 mg (p<0.001), respectively. In the volume-restricted setting the complete volume was absorbed by all swabs, volume release could only be detected for flocked swabs (2.7 mg; p<0.001). Highest amount of CFU release was detected for the MWE Dryswab in the unrestricted setting for both S. aureus and S. epidermidis with 1544 CFU and 553 CFU, respectively, lowest release for the Sarstedt neutral swab with 32 CFU and 17 CFU, respectively (p<0.001). In the volume-restricted setting MWE Σ-Swab released the highest bacterial amount with 135 CFU S. aureus and 55 CFU S. epidermidis, respectively, the lowest amount was released by Mast Mastaswab with 2 CFU S. aureus and 1 CFU S. epidermidis, respectively (p<0.001). Within the range of the utilized bacterial concentrations, uptake/release ratios were identical for the particular swab types and independent of the bacterial species. The influence of the swab type on subsequent diagnostic results is often underestimated. Uptake and release of the investigated bacteria vary significantly between different swab types and sampling conditions. For best diagnostic outcome swabs should be chosen according to the examined situation and the swab performance profile.

24 February 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PWPhilipp Warnke
Philipp Warnke
THTim Harnack
Tim Harnack
POPeter Ottl
Peter Ottl
GKGuenther Kundt
Guenther Kundt
APAndreas Podbielski
Andreas Podbielski
Staphylococcus aureus causes purulent bacterial infections with a considerable number of life-threatening complications and thus, is a serious cost factor in public health. Up to 50% of a given population could asymptomatically carry Staphylococcus aureus in their nares, thereby serving as a source for contact transmissions and endogenous infections. Nasal swab-based screening techniques are widely used to identify suchcarriers. This study investigated the skill of medical professionals in taking nasal swabs and the effect of teaching on improving bacterial recovery rates. 364 persons with different medical educational background participated in this study. A novel anatomically correct artificial nose model was implemented and inoculated with a numerically defined mixture of Staphylococcus aureus and Staphylococcus epidermidis bacteria. Utilizing regular clinical swabs, participants performed screening of the inoculated nose models before and after standardized theoretical, visual, and practical teaching. Recovery of bacteria was measured by standard viable count techniques. Data were analyzed statistically by nonparametric tests. It could be demonstrated that combined theoretical and practical teaching improved bacterial recovery rates. Even experienced medical professionals increased their detection levels after training. Recovery rates of bacteria varied significantly between trained (158.1 CFU) and untrained (47.5 CFU) participants (Wilcoxon test, p<0.001; Kolmogorov-Smirnov test, p<0.001). Swabs are commonly used to detect nasal carriage of Staphylococcus aureus in patients. The present teaching algorithm combined with the novel nose model offers an excellent precondition to improve knowledge and performance of this technique. Increased detection rates may prevent from contact transmission due to suboptimum hygienic patient handling. Consecutively, this effect could reduce costs for patient care. This study highlights the tremendous potential of combined theoretical, visual, and practical teaching methods in this field - and uncovers its actual necessity. Therefore, this training method can be recommended for all medical institutions.

5 September 2020 in Antibiotics
Verified
Journal Article
Open access
PDF file
PHPaul G. Higgins
Paul G. Higgins
RHRalf Matthias Hagen
Ralf Matthias Hagen
APAndreas Podbielski
Andreas Podbielski
HFHagen Frickmann
Hagen Frickmann
PWPhilipp Warnke
Philipp Warnke
Recently, a total of 32 carbapenem- and fluoroquinolone-resistant Acinetobacter baumannii (Ab) isolates was isolated from war-injured patients who were treated at German Bundeswehr Hospitals, and preliminarily typed by “DiversiLab” repetitive elements sequence-based (rep-) PCR. Core genome-based sequence typing was also used to provide more detailed epidemiological information. From the clusters observed by rep-PCR, selected Ab strains were subjected to Next Generation Sequencing (NGS) in order to compare them with international outbreak-associated Ab strains and to identify MLST (multi-locus sequence type) lineages, as well as to identify known resistance genes. Accordingly, NGS indicated higher diversity than rep-PCR, but also confirmed likely transmission events. The identified acquired carbapenem-resistant genes comprised blaOXA-23, blaOXA-72 and blaGES-12, as well as various other intrinsic and acquired resistance-associated genetic elements. All isolates clustered with the previously identified international clonal lineages IC1, IC2, IC6 and IC7, with corresponding Pasteur sequence types ST1, ST2, ST78 and ST25, respectively. In conclusion, the assessment confirmed a broad spectrum of resistance-associated genes in Ab isolated from war-injured patients from the Eastern Ukraine, and provided the first insights into locally abundant clonal lineages.

11 March 2021 in Antibiotics
Verified
Journal Article
Open access
PDF file
PHPaul G. Higgins
Paul G. Higgins
RHRalf Matthias Hagen
Ralf Matthias Hagen
BKBernd Kreikemeyer
Bernd Kreikemeyer
PWPhilipp Warnke
Philipp Warnke
APAndreas Podbielski
Andreas Podbielski
ULUlrike Loderstädt
Ulrike Loderstädt
At the Bundeswehr Hospitals of Hamburg and Westerstede, patients repatriated from subtropical war and crisis zones of Northern Africa and the Middle East were medically treated, including microbiological assessment. Within a six-year interval, 16 Acinetobacter spp. strains, including 14 Acinetobacter baumannii (Ab) isolates with resistance against carbapenems and origins in Afghanistan (n = 4), Iraq (n = 2), Libya (n = 2), and Syria (n = 8) were collected. While clonal relationships of Libyan and Syrian strains had been assessed by superficial next generation sequencing (NGS) and “DiversiLab” repetitive elements sequence-based (rep-)PCR so far, this study provides core genome-based sequence typing and thus more detailed epidemiological information. In detail, sequencing allowed a definitive species identification and comparison with international outbreak-associated Ab strains by core genome multi locus sequence typing (cgMLST) and the identification of MLST lineages, as well as the identification of known resistance genes. The sequence analysis allowed for the confirmation of outbreak-associated clonal clusters among the Syrian and Afghan Ab isolates, indicating likely transmission events. The identified acquired carbapenem resistance genes comprised blaOXA-23, blaOXA-58, blaNDM-1, and blaGES-11, next to other intrinsic and acquired, partly mobile resistance-associated genes. Eleven out of 14 Ab isolates clustered with the previously described international clonal lineages IC1 (4 Afghan strains), IC2 (6 Syrian strains), and IC7 (1 Syrian strain). Identified Pasteur sequence types of the 14 Ab strains comprised ST2 (Syrian), ST25 (Libyan), ST32 (Iraqi), ST81 (Afghan), ST85 (Libyan), and ST1112 (Syrian), respectively. In conclusion, the study revealed a broad spectrum of resistance genes in Ab isolated from war-injured patients from Northern Africa and the Middle East, thereby broadening the scarcely available data on locally abundant clonal lineages and resistance mechanisms.

27 July 2016 in Scientific Reports
Verified
Journal Article
Open access
PWPhilipp Warnke
Philipp Warnke
FPFriederike Pola Johanna Pohl
Friederike Pola Johanna Pohl
GKGuenther Kundt
Guenther Kundt
APAndreas Podbielski
Andreas Podbielski
Screening recommendations for multidrug-resistant Gram-negative bacteria comprise microbiological analyses from rectal swabs. However, essential specifications of the preanalytic steps of such screenings, i.e. the sampling technique, sampling devices and sampling site, are lacking. For standardized and optimum screening conditions these parameters are indispensable. Here, the optimum parameters were examined irrespective of the antibiotic resistance patterns of the target bacteria in order to establish a general basis for this type of screening. Swabs with rayon, polyurethane-cellular-foam and nylon-flocked tips were tested. Different sampling locations were evaluated, i.e. perianal, intraanal and deep intraanal. Subjects were swabbed and quantities of E. coli, K. pneumoniae, P. aeruginosa and A. baumannii were assessed. Overall prevalences of E. coli, K. pneumoniae, P. aeruginosa and A. baumannii were 94%, 16%, 12% and 2%, respectively. Bacterial recovery rates were independent from the sampling-timepoint during hospital stay. Polyurethane-cellular-foam or nylon-flocked swabs recovered significantly more bacteria as compared to rayon swabs. Intraanal swabbing resulted in significantly higher bacterial quantities as compared to perianal swabbing. In contrast, for the detection of A. baumannii, perianal swabbing seems more suitable than intraanal swabbing. Gender-related differences in bacterial recovery could be detected from perianal but not from intraanal swabs.