Fabien Doguet

Dr. Fabien Doguet

Cardiac Surgery, Normandie University, Rouen University Hospital, Rouen, France
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in European Heart Journal
Verified
Journal Article
Open access
PDF file
JDJulien Dreyfus
Julien Dreyfus
EAEtienne Audureau
Etienne Audureau
YBYohann Bohbot
Yohann Bohbot
ACAugustin Coisne
Augustin Coisne
YLYoan LAVIE-BADIE
Yoan LAVIE-BADIE
DMDavid Messika-Zeitoun
David Messika-Zeitoun
Aims : Isolated tricuspid valve surgery (ITVS) is considered to be a high-risk procedure, but in-hospital mortality is markedly variable. This study sought to develop a dedicated risk score model to predict the outcome of patients after ITVS for severe tricuspid regurgitation (TR). Methods and results : All consecutive adult patients who underwent ITVS for severe non-congenital TR at 12 French centres between 2007 and 2017 were included. We identified 466 patients (60 ± 16 years, 49% female, functional TR in 49%). In-hospital mortality rate was 10%. We derived and internally validated a scoring system to predict in-hospital mortality using multivariable logistic regression and bootstrapping with 1000 re-samples. The final risk score ranged from 0 to 12 points and included eight parameters: age ≥70 years, New York Heart Association Class III–IV, right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin, left ventricular ejection fraction <60%, and moderate/severe right ventricular dysfunction. Tricuspid regurgitation mechanism was not an independent predictor of outcome. Observed and predicted in-hospital mortality rates increased from 0% to 60% and from 1% to 65%, respectively, as the score increased from 0 up to ≥9 points. Apparent and bias-corrected areas under the receiver operating characteristic curves were 0.81 and 0.75, respectively, much higher than the logistic EuroSCORE (0.67) or EuroSCORE II (0.63). Conclusion : We propose TRI-SCORE as a dedicated risk score model based on eight easy to ascertain parameters to inform patients and physicians regarding the risk of ITVS and guide the clinical decision-making process of patients with severe TR, especially as transcatheter therapies are emerging (www.tri-score.com).

30 August 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
JDJulien Dreyfus
Julien Dreyfus
FJFernando Juarez-Casso
Fernando Juarez-Casso
ASAlessandra Sala
Alessandra Sala
MCManuel Carnero-Alcazar
Manuel Carnero-Alcazar
AEAndrea Eixerés-Esteve
Andrea Eixerés-Esteve
DMDavid Messika-Zeitoun
David Messika-Zeitoun
Background and Aims: Severe tricuspid regurgitation is associated with increased mortality rates, but benefit of its correction and ideal timing are not clearly determined. This study aimed to identify patient subsets who might benefit from the surgery. Methods: In TRIGISTRY, an international cohort study of consecutive patients with severe isolated functional tricuspid regurgitation (33 centres, 10 countries), survival rates up to 10 years were compared between patients who underwent isolated tricuspid valve surgery (repair or replacement) and those conservatively managed, overall and according to TRI-SCORE category (low: ≤3, intermediate: 4–5, and high: ≥6). Results: One thousand and two hundred seventeen were managed conservatively, and 551 underwent isolated tricuspid valve surgery (200 repairs and 351 replacements). TRI-SCORE distribution was 33% low, 32% intermediate, and 35% high. At 10 years, survival rates were similar between surgical and conservative management [41% vs. 36%; hazard ratio (HR) .97; 95% confidence interval (CI) .88–1.08, P = .57]. Surgery improved survival compared with conservative management in the low TRI-SCORE category (72% vs. 44%; HR .27; 95% CI .20–.37, P < .0001), but not in the intermediate (36% vs. 37%; HR 1.17; 95%CI .98–1.40, P = .09) or high categories (20% vs. 24%; HR 1.06; 95% CI .91–1.25, P = .45). Both repair and replacement improved survival in the low TRI-SCORE category (84% and 61% vs. 44%; HR .11; 95% CI .06–.19, P < .0001, and HR .65; 95% CI .47–.90, P = .009). Repair showed benefit in the intermediate category (59% vs. 37%; HR .49; 95% CI .35–.68, P < .0001) while replacement was possibly harmful (25% vs. 37%; HR 1.43; 95% CI 1.18–1.72, P = .0002). Conclusions: Higher survival rates were observed with repair than replacement and benefit of intervention declined as TRI-SCORE increased with no benefit of any type of surgery in the high TRI-SCORE category. These results emphasize the importance of timely intervention and patient selection to achieve the best outcomes and the need for randomized controlled trials.

1 October 2010 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
FDFabien Doguet
Fabien Doguet
MGMathieu Godin
Mathieu Godin
GLGuillaume Lebreton
Guillaume Lebreton
HEHélène Eltchaninoff
Hélène Eltchaninoff
ACAlain Cribier
Alain Cribier
PLPierre Yves Litzler
Pierre Yves Litzler
Cardiac surgery can relieve symptoms and improve the prognosis of patients with aortic stenosis. However, surgery-related morbidity and mortality are high when severe cardiac or extracardiac factors co-exist. We report the outcome of percutaneous balloon aortic valvuloplasty (BAV) as a bridge to aortic valve replacement (AVR) in temporarily inoperable patients in our institution. All patients who, between January 2002 and December 2006, underwent a bridging percutaneous BAV and had an AVR performed 8-14 weeks later, were included in the study. Clinical and investigational data were collected retrospectively from the patients' files. Follow-up was performed by telephonic interview. Twenty-five patients were included in the analysis (median age 71.9 years). Operative risk decreased from 18.6% before BAV to less than 13% before AVR, according to the logistical European System for Cardiac Operative Risk Evaluation (EuroSCORE). Median ejection fraction (EF) was 40% before dilation compared with 44% after BAV. The necessity for BAV included acute pulmonary oedema (8%), cardiac failure (64%), cardiogenic shock (16%), syncope (8%) and EF<10% (4%). Complications included low output (28%), renal failure (20%), septic shock (4%) and cerebrovascular accident (8%). One postoperative hospital death was observed. The median length of stay in the intensive care unit (ICU) was 44 days, and the median total hospital stay was 10 days. BAV used as a bridging procedure to improve cardiovascular function prior to AVR is an interesting therapeutic approach in patients with aortic stenosis and haemodynamic failure. The postoperative course after AVR was also improved in our patients.

24 February 2023 in Heart
Verified
Journal Article
Closed access
PDF file
JDJulien Dreyfus
Julien Dreyfus
YByohann bohbot
yohann bohbot
ACAugustin Coisne
Augustin Coisne
YLYoan LAVIE-BADIE
Yoan LAVIE-BADIE
MFMichele Flagiello
Michele Flagiello
DMDavid Messika-Zeitoun
David Messika-Zeitoun
Objectives The TRI-SCORE reliably predicts in-hospital mortality after isolated tricuspid valve surgery (ITVS) on native valve but has not been tested in the setting of redo interventions. We aimed to evaluate the predictive value of the TRI-SCORE for in-hospital mortality in patients with redo ITVS and to compare its accuracy with conventional surgical risk scores. Methods Using a mandatory administrative database, we identified all consecutive adult patients who underwent a redo ITVS at 12 French tertiary centres between 2007 and 2017. Baseline characteristics and outcomes were collected from chart review and surgical scores were calculated. Results We identified 70 patients who underwent a redo ITVS (54±15 years, 63% female). Prior intervention was a tricuspid valve repair in 51% and a replacement in 49%, and was combined with another surgery in 41%. A tricuspid valve replacement was performed in all patients for the redo surgery. Overall, in-hospital mortality and major postoperative complication rates were 10% and 34%, respectively. The TRI-SCORE was the only surgical risk score associated with in-hospital mortality (p=0.005). The area under the receiver operating characteristic curve for the TRI-SCORE was 0.83, much higher than for the logistic EuroSCORE (0.58) or EuroSCORE II (0.61). The TRI-SCORE was also associated with major postoperative complication rates and survival free of readmissions for heart failure. Conclusion Redo ITVS was rarely performed and was associated with an overall high in-hospital mortality and morbidity, but hiding important individual disparities. The TRI-SCORE accurately predicted in-hospital mortality after redo ITVS and may guide clinical decision-making process (www.tri-score.com).

18 May 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
ELEmmanuel Lansac
Emmanuel Lansac
ICIsabelle Di Centa
Isabelle Di Centa
PDPichoy Danial
Pichoy Danial
OBOlivier Bouchot
Olivier Bouchot
EAEric Arnaud-Crozat
Eric Arnaud-Crozat
FTFlorence Tubach
Florence Tubach
OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.

24 June 2022 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
Meindert PalmenMeindert Palmen
Meindert Palmen
ENEmiliano Navarra
Emiliano Navarra
JBJohannes Bonatti
Johannes Bonatti
UFUlrich Franke
Ulrich Franke
SCStepan Cerny
Stepan Cerny
DPDaniel Pereda
Daniel Pereda
The adoption of robotics in cardiac surgery is increasing rapidly [ 1]. The unparalleled range of motion and precision combined with 3-dimensional (3D) vision in a minimally invasive surgical setting facilitates complex cardiosurgical procedures without compromising on the surgical techniques utilized. This unique combination of innovative characteristics holds the promise to improve outcome in various groups of patients. Until the recent surge in robotic cases, the penetrance of robotics in cardiac surgery has been low for decades, likely related to the high initial costs in combination with a lack of structured training and mentoring programs. Furthermore, the new European Medical Device Regulation may hamper further adoption of this technique because it seems to lead to the paradoxical withdrawal of robotic tools from the market rather than the anticipated improvement in quality.