Taiwen Tang

Dr. Taiwen Tang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Chen WuChen Wu
Chen Wu
TTTaiwen Tang
Taiwen Tang
Janaka ElangageJanaka Elangage
Janaka Elangage
DKDenesh Krishnasamy
Denesh Krishnasamy
It is always an interesting research topic for digital receiver (DRX) designers to develop a DRX with (1) ultrawide instantaneous bandwidth (IBW), (2) high sensitivity, (3) fine time-of-arrival-measurement resolution (TMR), and (4) fine frequency-measurement resolution (FMR) for weak signal detection. This is because designers always want their receivers to have the widest possible IBW to detect far away and/or weak signals. As the analog-to-digital converter (ADC) rate increasing, the modern DRX IBW increases continuously. To improve the signal detection based on blocking FFT (BFFT) method, this paper introduces the new concept of accumulatively increasing receiver sensitivity (AIRS) for DRX design. In AIRS, a very large number of frequency-bins can be used for a given IBW in the time-to-frequency transform (TTFT), and the DRX sensitivity is cumulatively increased, when more samples are available from high-speed ADC. Unlike traditional FFT-based TTFT, the AIRS can have both fine TMR and fine FMR simultaneously. It also inherits all the merits of the BFFT, which can be implemented in an embedded system. This study shows that AIRS-based DRX is more efficient than normal FFT-based DRX in terms of using time-domain samples. For example, with a probability of false alarm rate of 10−7, for N=220 frequency-bins with TMR = 50 nSec, FMR = 2.4414 KHz, IBW > 1 GHz and ADC rate at 2.56 GHz, AIRS-based DRX detects narrow-band signals at about −42 dB of input signal-to-noise ratio (Input-SNR), and just uses a little less than N/2 real-samples. However, FFT-based DRX have to use all N samples. Simulation results also show that AIRS-based DRX can detect frequency-modulated continuous wave signals with ±0.1, ±1, ±10 and ±100 MHz bandwidths at about −39.4, −35.1, −30.2, and −25.5 dB of Input-SNR using about 264.6 K, 104.7 K, 40.2 K and 18.3 K real-samples, respectively, in 220 frequency-bins for TTFT.

25 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TTTaiwen Tang
Taiwen Tang
Chen WuChen Wu
Chen Wu
Janaka ElangageJanaka Elangage
Janaka Elangage
In this paper, a novel signal processing algorithm for mitigating the radar blind speed problem of moving target indication (MTI) for frequency modulated continuous wave (FMCW) multi-target tracking radars is proposed. A two-phase staggered pulse repetition interval (PRI) solution is introduced to the FMCW radar system. It is implemented as a time-varying MTI filter using twice the hardware resources as compared to a uniform PRI MTI filter. The two-phase staggered PRI FMCW waveform is still periodic with a little more than twice the period of the uniform PRI radar. We also propose a slow time signal integration scheme for the radar detector using the post-fast Fourier transformation Doppler tracking loop. This scheme introduces 4.77 dB of extra signal processing gain to the signal before the radar detector compared with the original uniform PRI FMCW radar. The validation of the algorithm is done on the field programmable logic array in the loop test bed, which accurately models and emulates the target movement, line of sight propagation and radar signal processing. A simulation run of tracking 16 s of the target movement near or at the radar blind speed shows that the total degradation from the raw post-fast Fourier transformation received signal to noise ratio is about 2 dB. With a 20 dB post-processing signal to noise ratio of the proposed algorithm for the moving target at around a 20 km range and with about a −3.5 dB m2 radar cross section at a 1.5 GHz carrier frequency, the tracking errors of the two-dimensional angles with a 4×4 digital phased array are less than 0.2 degree. The range tracking error is about 28 m.

28 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
TTTaiwen Tang
Taiwen Tang
Chen WuChen Wu
Chen Wu
Janaka ElangageJanaka Elangage
Janaka Elangage
In this paper, a high-performance antenna array system model is presented to analyze moving-object-skin-returns and track them in the presence of stationary objects using frequency modulated continuous wave (FMCW). The main features of the paper are bonding the aspects of antenna array and electromagnetic (EM) wave multi-skin-return modeling and simulation (M&S) with the aspects of algorithm and measurement/tracking system architecture. The M&S aspect models both phase and amplitude of the signal waveform from a transmitter to the signal processing in a receiver. In the algorithm aspect, a novel scheme for FMCW signal processing is introduced by combining time- and frequency-domain methods, including a vector moving target indication filter and a vector direct current canceller in time-domain, and a constant false alarm rate detector and a mono-pulse digital beamforming angle tracker in frequency-domain. In addition, unlike previous designs of using M × N fast Fourier transform (FFT) for an M × N array, only four FFTs are used, which tremendously save time and space in hardware. With the presented model, the detection of the moving-target-skin-return in stationary objects under a noisy environment is feasible. Therefore, to track long range and high-speed objects, the proposed technique is promising. Using a scenario having (1) a target with 17 dBm2 radar cross section (RCS) at about 40 km range with 5.936 Mach speed and 11.6 dB post processing signal to noise ratio, and (2) a strong stationary clutter with 37 dBm2 RCS located at the proximity of the target, it demonstrates that the root-mean-square errors of range, angle, and Doppler measurements are about 26 m, 0.68 degree, and 1100 Hz, respectively.

26 November 2020 in Preprints.org
Verified
Preprint
Open access
PDF file
TTTaiwen Tang
Taiwen Tang
Chen WuChen Wu
Chen Wu
Janaka ElangageJanaka Elangage
Janaka Elangage
In this paper, a high-performance antenna array system model is presented to analyze moving-object-skin-returns and track them in the presence of stationary objects using frequency modulated continuous wave (FMCW). The main features of the paper are bonding the aspects of antenna array and electromagnetic (EM) wave multi-skin-return modeling and simulation (M&S) with the aspects of algorithm and measurement/tracking system architecture. The M&S aspect models both phase and amplitude of the signal waveform from a transmitter to the signal processing in a receiver. In the algorithm aspect, a novel scheme for FMCW signal processing is introduced by combining time- and frequency-domain methods, including a vector moving target indication filter and a vector direct current canceller in time-domain, and a constant false alarm rate detector and a mono-pulse digital beamforming angle tracker in frequency-domain. In addition, unlike previous designs of using M×N fast Fourier transform (FFT) for an M×N array, only four FFTs are used, which tremendously saves time and space in hardware. With the presented model, the detection of the moving-target-skin-return in stationary objects under a noisy environment is feasible. Therefore, to track long range and high-speed objects, the proposed technique is promising. Using a scenario having 1) a target with 17 dBm2 radar cross section (RCS) at about 40 km range with 5.93 Mach speed and 11.6 dB post processing signal to noise ratio, and 2) a strong stationary clutter with 37 dBm2 RCS located at the proximity of the target, it demonstrates that the root-mean-square errors of range, angle and Doppler measurements are about 26 meters, 0.68 degree and 1100 Hz, respectively.