Aneta Olszewska

Dr. Aneta Olszewska

Silesian University of Technology, Faculty of Electrical Engineering, Department of Optoelectronics, Gliwice, Poland
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Archives of Acoustics
Verified
Journal Article
Open access
PDF file
Aneta OlszewskaAneta Olszewska
Aneta Olszewska
Franciszek WitosFranciszek Witos
Franciszek Witos
In this paper, the properties of AE signals originating from phenomena occurring during magnetization of ferromagnetic materials which are used to construct power transformer cores are presented. The AE signals in a selected power oil transformer were recorded and analyzed. The analysis included, i.e., time, frequency, and time-frequency analyses, calculations of amplitude distributions of the signals and defined AE descriptors, determination of the descriptor map on the side walls of transformers, as well as a detailed analysis of selected part of the signals. The maps of descriptors were analyzed in the frequency bands of 20–70 kHz, 70–100 kHz, and 100–200 kHz. The analysis of the properties of the signals was performed in time and frequency domains. Based on the analysis, there were identified the AE signals originating from the phenomena occurring during the core magnetization of a power oil transformer. To identify those phenomena, the maps of the ADC descriptor calculated in the band of 20–70 kHz when selecting the measurement points in which there were no AE sources from partial discharges were used. An analysis of magnetoacoustic emission signals in the bands of 70–100 kHz and 100–200 kHz was also performed. The analysis of the signal properties in such an extended frequency range allowed determining the properties of the magnetoacoustic signals coming from core sheets of power oil transformers.


15 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Franciszek WitosFranciszek Witos
Franciszek Witos
Aneta OlszewskaAneta Olszewska
Aneta Olszewska
ZOZbigniew Opilski
Zbigniew Opilski
ALAgnieszka Lisowska-Lis
Agnieszka Lisowska-Lis
GSGrzegorz Szerszeń
Grzegorz Szerszeń
In this paper, the research methodology and the results of the analysis carried out using the acoustic emission (AE) and thermal imaging for a selected oil power transformer are presented. The basis for the research, by means of the AE method, was the author’s patented research method. The AE descriptor maps on the side walls of the tested transformer along with the location of areas with increased AE activity and an analysis of the properties of AE signals recorded at the measurement points located in these areas have been performed. The results showed no partial discharges that could threaten further operation of the tested transformer as well as three areas where increased magnetoacoustic emission occurred. Thermal imaging studies were carried out in the 7.5 μm < λ < 13 μm band. Three areas were located on the calculated thermograms: the entire upper surface of the transformer tank and two areas on the side walls of the tested transformer in which increased IR radiation occurred. The results of the analysis of the research results for the two methods correspond with each other, having a common part, and complement each other giving a broader description of studied phenomena.

28 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
Franciszek WitosFranciszek Witos
Franciszek Witos
Aneta OlszewskaAneta Olszewska
Aneta Olszewska
This paper presents the authors’ multi-channel measurement systems designed and built to conduct research on partial discharge phenomena using the acoustic emission method. The systems provide real-time monitoring, recording of signals and analysis of recorded signals. The analysis is carried out in time, frequency, time-frequency and discrimination threshold domains. In particular, a descriptor with the ADC acronym is defined, which ranks the signals according to the so-called degree of advancement. Studies have been carried out, showing that for a single partial discharge source, when tested in parallel, using the electrical and acoustic emission methods, the ranking of the signals using this descriptor is identical to the ranking according to the value of the apparent charge introduced by sources. This paper presents the authors’ patented method of partial discharge location and identification in power oil transformers. The results of tests of power oil transformer at the test station, conducted in parallel with the electric method and the authors’ method, and the results of tests in three selected transformers carried out during ongoing in-situ operation using the authors’ method are presented. Based on these results, the authors make diagnoses of the condition of the insulation systems in the tested transformers. The inspections of these transformers confirm the diagnoses.

27 June 2017 in Archives of Acoustics
Verified
Journal Article
Open access
PDF file
Franciszek WitosFranciszek Witos
Franciszek Witos
GSGrzegorz Szerszeń
Grzegorz Szerszeń
ZOZbigniew Opilski
Zbigniew Opilski
MSMaciej Setkiewicz
Maciej Setkiewicz
Aneta OlszewskaAneta Olszewska
Aneta Olszewska
MSMarek Szadkowski
Marek Szadkowski
In the paper, there are presented a general description of the constructed measuring system 8AE-PD, the results of calibration of this system by the Hsu-Nielsen method as well as the testing of the measuring system during recording signals generated by Hsu-Nielsen sources in a steel plate and a modeled partial discharge (PD) source. There is also presented the methodology of investigations by the calibrated acoustic emission method. The results of analyses of PD signals coming from the modeled sources are given. In particular, there are described the properties of acoustic emission (AE) signals generated by the PDs as well as the dependencies of the peak-to-peak voltage Umm, the RMS voltage Urms and the descriptors of acronyms ADP and ADC on the apparent charge Q introduced by the modeled PD source. There are determined the limit values of the apparent charge Q introduced by the modeled PD source for which the recorded signal is identified as originating from the PDS.

1 October 2011 in Acta Physica Polonica A
Verified
Journal Article
Closed access
Franciszek WitosFranciszek Witos
Franciszek Witos
Aneta OlszewskaAneta Olszewska
Aneta Olszewska
GSG. Szerszeń
G. Szerszeń