ChiaYu Lin

Dr. ChiaYu Lin

China Medical University Hospital, Taichung, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
PCPo-Chen Chen
Po-Chen Chen
CCChien-Chun Chang
Chien-Chun Chang
HCHsien-Te Chen
Hsien-Te Chen
CLChiaYu Lin
ChiaYu Lin
THTsung-Yu Ho
Tsung-Yu Ho
HHHorng-Chaung Hsu
Horng-Chaung Hsu
Background. The pedicle screw is one of the main tools used in spinal deformity correction surgery. Robotic and navigated surgeries are usually used, and they provide superior accuracy in pedicle screw placement than free-hand and fluoroscopy-guided techniques. However, their high cost and space limitation are problematic. We provide a new solution using 3D printing technology to facilitate spinal deformity surgery. Methods. A workflow was developed to assist spinal deformity surgery using 3D printing technology. The trajectory and profile of pedicle screws were determined on the image system by the surgical team. The engineering team designed drill templates based on the bony surface anatomy and the trajectory of pedicle screws. Their effectiveness and safety were evaluated during a preoperative simulation surgery. The surgery consisted in making a pilot hole through the drill template on a computed tomography- (CT-) based, full-scale 3D spine model for every planned segment. Somatosensory evoke potential (SSEP) and motor evoke potential (MEP) were used for intraoperative neurophysiological monitoring. Postoperative CT was obtained 6 months after the correction surgery to confirm the screw accuracy. Results. From July 2015 to November 2016, we performed 10 spinal deformity surgeries with 3D printing technology assistance. In total, 173 pedicle screws were implanted using drill templates. No notable change in SSEP and MEP or neurologic deficit was noted. Based on postoperative CT scans, the acceptable rate was 97.1% (168/173). We recorded twelve pedicle screws with medial breach, six with lateral breach, and five with inferior breach. Medial breach (12/23) was the main type of penetration. Lateral breach occurred mostly in the concave side (5/6). Most penetrations occurred above the T8 level (69.6%, 16/23). Conclusion. 3D printing technology provides an effective alternative for spinal deformity surgery when expensive medical equipment, such as intraoperative navigation and robotic systems, is unavailable.

1 June 2020 in World Neurosurgery
Verified
Journal Article
Closed access
CLChiaYu Lin
ChiaYu Lin
CCChien-Chun Chang
Chien-Chun Chang
CTChun Tseng
Chun Tseng
YCYen-Jen Chen
Yen-Jen Chen
CTChun-Hao Tsai
Chun-Hao Tsai
HCHsien-Te Chen
Hsien-Te Chen

21 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ILI-Hao Lin
I-Hao Lin
TLTsung-Li Lin
Tsung-Li Lin
HCHao-Wei Chang
Hao-Wei Chang
CLChiaYu Lin
ChiaYu Lin
CTChun-Hao Tsai
Chun-Hao Tsai
CHChin-Jung Hsu
Chin-Jung Hsu
Background: We investigated the superiority of arthroscopy-assisted reduction and internal fixation (ARIF) to open reduction and internal fixation (ORIF) for treating glenoid fracture with scapular involvement. Methods: We retrospectively enrolled patients with glenoid fracture who underwent ARIF or ORIF from 2010–2020. Radiographic outcomes were assessed, and clinical outcomes (active range of motion [ROM], visual analog scale [VAS], Constant, and Disabilities of the Arm, Shoulder and Hand [DASH]) were evaluated 12 months postoperatively. Results: Forty-four patients with Ideberg type II–VI glenoid fractures (ARIF: 20; ORIF: 24; follow-up 12–22 months) were included. Union was achieved in all patients. Active ROM values were comparable between the approaches. Constant and DASH scores were non-significantly better with ARIF (90.9 ± 9.2 vs. 86.6 ± 18.1 [p = 0.341] and 6.8 ± 9.4 vs. 9.3 ± 21.3 [p = 0.626], respectively). However, VAS scores were significantly lower with ARIF (1.5 ± 0.6 vs. 2.7 ± 1.4, p = 0.001). Associated intra-articular lesions (articular depressions [80%], superior labral anterior-posterior tear [20%], labral tears [30%]) were found in most ARIF cases and were repaired during ARIF. Conclusions: For glenoid fracture with scapular involvement, ARIF allows accurate diagnosis of fracture pattern and the management of associated intra-articular lesions, with better pain control outcomes than ORIF. Thus, arthroscopy-assistant surgery should be considered in patient with glenoid fracture.

1 May 2019
Verified
Journal Article
Closed access
CLChiaYu Lin
ChiaYu Lin
CCChien-Chun Chang
Chien-Chun Chang
YCYen-Jen Chen
Yen-Jen Chen
CTChun-Hao Tsai
Chun-Hao Tsai
HTHsi-Kai Tsou
Hsi-Kai Tsou
HHHorng-Chaung Hsu
Horng-Chaung Hsu

15 November 2022 in Medicina
Verified
Journal Article
Open access
PDF file
JMJui-Ting Mao
Jui-Ting Mao
HCHao-Wei Chang
Hao-Wei Chang
TLTsung-Li Lin
Tsung-Li Lin
ILI-Hao Lin
I-Hao Lin
CLChiaYu Lin
ChiaYu Lin
CHChin-Jung Hsu
Chin-Jung Hsu
Background and Objectives: Arm wrestling is a simple and popular activity among young people that causes distal-third humeral fractures. However, injury to the young population may cause economic loss; therefore, they need to return to work as soon as possible. Accordingly, we aimed to compare radiological and functional outcomes of distal-third humeral fractures caused by arm wrestling treated with double and single plating. Materials and Methods: Thirty-four patients with distal-third humeral fractures caused by arm wrestling were treated between January 2015 and January 2021. They were separated into double- and single-plating groups and treated using a triceps-sparing approach. Regular follow-up was performed to evaluate elbow functionality, range of motion, bone union, and complications; the American Shoulder and Elbow Surgeons score was used for functional assessment. Results: Patients treated with single plating exhibited union rate, union time, and elbow range of motion similar to those of patients treated with double plating; however, they exhibited better pain and functional outcomes (American Shoulder and Elbow Surgeons score) at 2 weeks, 1 month, and 3 months postoperatively (84.50 ± 5.01 vs. 61.70 ± 12.53 at 2 weeks, 96.20 ± 2.63 vs. 84.25 ± 14.56 at 1 month, and 100.00 vs. 94.76 ± 9.71 at 3 months, p < 0.05). The two groups exhibited no significant differences after 1 year (100.00 vs. 98.54 ± 3.99, p < 0.13). The overall complication rate was significantly higher in patients treated with double plating than in those treated with single plating (18.75% vs. 5.56%). Radial nerve palsy was observed in patients in both groups. Conclusions: In patients with distal-third humeral fractures caused by arm wrestling, single plating provides a union rate and elbow range of motion similar to those of double plating, with significantly fewer complications and lower surgical time and blood loss with improved early functional outcomes.

1 March 2022
Verified
Journal Article
Closed access
ILI-Hao Lin
I-Hao Lin
CLChiaYu Lin
ChiaYu Lin
CCChien-Chun Chang
Chien-Chun Chang
YCYen-Jen Chen
Yen-Jen Chen
PHPang-Hsuan Hsiao
Pang-Hsuan Hsiao
HCHsien-Te Chen
Hsien-Te Chen