Mathieu David Santin

Dr. Mathieu David Santin

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Cortex
Verified
Journal Article
Closed access
KHKatja Heuer
Katja Heuer
OGOmer Faruk Gulban
Omer Faruk Gulban
PBPierre-Louis Bazin
Pierre-Louis Bazin
AOAnastasia Osoianu
Anastasia Osoianu
RVRomain Valabregue
Romain Valabregue
RTRoberto Toro
Roberto Toro

1 January 2020 in NeuroImage
Verified
Journal Article
Open access
VOValéry Ozenne
Valéry Ozenne
CCCharlotte Constans
Charlotte Constans
PBPierre Bour
Pierre Bour
MSMathieu David Santin
Mathieu David Santin
RVRomain Valabrègue
Romain Valabrègue
BQBruno Quesson
Bruno Quesson
Transcranial focus ultrasound applications applied under MRI-guidance benefit from unrivaled monitoring capabilities, allowing the recording of real-time anatomical information and biomarkers like the temperature rise and/or displacement induced by the acoustic radiation force. Having both of these measurements could allow for better targeting of brain structures, with improved therapy monitoring and safety. We investigated the use of a novel MRI-pulse sequence described previously in Bour et al., (2017) to quantify both the displacement and temperature changes under various ultrasound sonication conditions and in different regions of the brain. The method was evaluated in vivo in a non-human primate under anesthesia using a single-element transducer (f = 850 kHz) in a setting that could mimic clinical applications. Acquisition was performed at 3 T on a clinical imaging system using a modified single-shot gradient echo EPI sequence integrating a bipolar motion-sensitive encoding gradient. Four slices were acquired sequentially perpendicularly or axially to the direction of the ultrasound beam with a 1-Hz update frequency and an isotropic spatial resolution of 2-mm. A total of twenty-four acquisitions were performed in three different sets of experiments. Measurement uncertainty of the sequence was investigated under different acoustic power deposition and in different regions of the brain. Acoustic simulation and thermal modeling were performed and compared to experimental data. The sequence simultaneously provides relevant information about the focal spot location and visualization of heating of brain structures: 1) The sequence localized the acoustic focus both along as well as perpendicular to the ultrasound direction. Tissue displacements ranged from 1 to 2 μm. 2) Thermal rise was only observed at the vicinity of the skull. Temperature increase ranged between 1 and 2 °C and was observed delayed relative the sonication due to thermal diffusion. 3) The fast frame rate imaging was able to highlight magnetic susceptibility artifacts related to breathing, for the most caudal slices. We demonstrated that respiratory triggering successfully restored the sensitivity of the method (from 0.7 μm to 0.2 μm). 4) These results were corroborated by acoustic simulations. The current rapid, multi-slice acquisition and real-time implementation of temperature and displacement visualization may be useful in clinical practices. It may help defining operational safety margins, improving therapy precision and efficacy. Simulations were in good agreement with experimental data and may thus be used prior treatment for procedure planning.

23 February 2016 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
MSMathieu David Santin
Mathieu David Santin
MDM. Didier
M. Didier
RVR. Valabrègue
R. Valabrègue
LCL. Yahia Cherif
L. Yahia Cherif
DGD. García‐Lorenzo
D. García‐Lorenzo
SLS. Lehéricy
S. Lehéricy

1 October 2013 in NeuroImage
Verified
Journal Article
Closed access
MSMathieu David Santin
Mathieu David Santin
TDThomas Debeir
Thomas Debeir
LBLori Bridal
Lori Bridal
TRThomas Rooney
Thomas Rooney
MDMarc Dhenain
Marc Dhenain

1 January 2019 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
SSSophie Bernadette Sébille
Sophie Bernadette Sébille
ARAnne-Sophie Rolland
Anne-Sophie Rolland
MWMarie-Laure Welter
Marie-Laure Welter
EBEric Bardinet
Eric Bardinet
MSMathieu David Santin
Mathieu David Santin

30 January 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MAMohammed H Ahmed
Mohammed H Ahmed
IHIsaias HERNANDEZ
Isaias HERNANDEZ
EQEmie Quissac
Emie Quissac
NLNolwenn Lemaire
Nolwenn Lemaire
CGCoralie Guerin
Coralie Guerin
Ahmed IdbaihAhmed Idbaih
Ahmed Idbaih
Therapeutic antibodies targeting immune checkpoints have shown limited efficacy in clinical trials in glioblastoma (GBM) patients. Ultrasound-mediated blood–brain barrier opening (UMBO) using low-intensity pulsed ultrasound improved drug delivery to the brain. We explored the safety and the efficacy of UMBO plus immune checkpoint inhibitors in preclinical models of GBM. A blood–brain barrier (BBB) opening was performed using a 1 MHz preclinical ultrasound system in combination with 10 µL/g microbubbles. Brain penetration of immune checkpoint inhibitors was determined, and immune cell populations were evaluated using flow cytometry. The impact of repeated treatments on survival was determined. In syngeneic GL261-bearing immunocompetent mice, we showed that UMBO safely and repeatedly opened the BBB. BBB opening was confirmed visually and microscopically using Evans blue dye and magnetic resonance imaging. UMBO plus anti-PDL-1 was associated with a significant improvement of overall survival compared to anti-PD-L1 alone. Using mass spectroscopy, we showed that the penetration of therapeutic antibodies can be increased when delivered intravenously compared to non-sonicated brains. Furthermore, we observed an enhancement of activated microglia percentage when combined with anti-PD-L1. Here, we report that the combination of UMBO and anti-PD-L1 dramatically increases GL261-bearing mice’s survival compared to their counterparts treated with anti-PD-L1 alone. Our study highlights the BBB as a limitation to overcome in order to increase the efficacy of anti-PD-L1 in GBM and supports clinical trials combining UMBO and in GBM patients.