Building-integrated rooftop greenhouses (BiRTGs) are innovative vertical farms consisting of a greenhouse on the roof of a building. BiRTGs can provide environmental benefits by recycling energy, carbon dioxide, and water between the greenhouse and the building. Moreover, BiRTGs can reduce cooling and heating loads by reducing the exposure of the building surface to heat gains/losses through the roof. However, the benefits of BiRTGs have not yet been completely elucidated from an energy perspective. This study aimed to analyse the energy-saving efficiency of BiRTGs using building energy simulations (BES) and computational fluid dynamics (CFD) techniques. BES is a calculation method for analysing the heating and cooling loads of buildings; however, it was difficult to consider time-dependent changes in the ventilation characteristics in the BES model. CFD can be used to calculate more detailed ventilation characteristics of an experimental facility. Thus, CFD and the BES were combined to obtain more accurate BES-based data. The BES-computed annual energy load for a single-span greenhouse in which tomatoes were grown was 490,128 MJ, whereas the annual energy load for growing tomatoes in a BiRTG resulted in a 5.2% reduction, on average (464,673 MJ). The energy-saving effects were positive from October to April because the BiRTG helped transmit heat energy transmitted from the building to the greenhouse. Regarding the total energy load in the BiRTG after alternating the air temperature management (ATM), the heating energy load was reduced in the winter. ATM was expected to apply from November to March, with average energy savings of 11.8%.
With the rise in livestock production, the odour concentration emitted from livestock facilities has significantly increased. For this reason, odour complaints have become a major issue. The dispersion of the odour into the atmosphere is affected by various factors (wind speed, wind direction, atmospheric stability, terrain condition, ventilation type, and so on). Thus, a thorough analysis on the factor influencing odour dispersion is necessary to establish regulations and policies for odour management. Therefore, this research aimed to evaluate odour dispersion generated from a pig house with complex terrain using computational fluid dynamics (CFD) and to statistically determine the key factor for odour dispersion. By comparing CFD-computed results with field-measured data, an appropriate grid size, time step, and turbulence model of the CFD model were determined. Considering various factors, case studies were performed using the validated CFD model. The CFD-computed results showed that odour dispersion distance at the level of 1 OU m−3 ranged from 129.7 to 1488.1 m. The prediction of odour dispersion distance varies with the change of factor being analysed. Finally, the statistical analysis showed that the most influential factor that affected odour dispersion distance was the wind speed with a t-value: −9.057.
A substantial reduction in the environmental impacts related to the construction and operation of agricultural buildings is needed to adapt to the continuing development of agriculture. The life cycle assessment (LCA) is a methodology used to quantify the environmental impact of different processes involved in the production and therefore has been increasingly applied to assess the environmental burden. However, most LCA-related research studies have focused on the overall environmental impact of the entire system without considering the energy load of the agricultural buildings. By integrating the LCA tool with other design tools such as the building energy simulation (BES), the identification of environmental hotspots and the mitigation options become possible during the design process. Thus, the objective of the paper was to identify the current integration approaches used to combine BES and LCA results to assess the environmental impact of different heating systems such as absorption heat pump (AHP) using energy from thermal effluent, electricity-powered heat pump and kerosene-powered boilers used in a conventional multi-span Korean greenhouse. The assessment result revealed that the environmental impact caused using a kerosene-powered boiler is largest in terms of the acidification potential (AP), global warming potential (GWP) and Eutrophication Potential (EP) of 1.15 × 100 kg SO2-eq, 1.13 × 102 kg CO2-eq and 1.62 × 10−1 kg PO4-eq, respectively. Detailed analysis of the result showed that the main contributor for greenhouse gas emission was caused by the type, amount and source of energy used to heat the greenhouse, which contributed to a maximum of 86.59% for case 1, 96.69% for case 2 and a maximum of 96.47% for case 3, depending on the type of greenhouse gas being considered.
As the pig industry develops rapidly, various problems are appearing both inside and outside the pig houses. In particular, in the case of pig houses, it is difficult to solve the main problems even if automation and mechanization are applied with ICT technology. The main current issues are: (1) preventing infectious diseases amongst livestock, (2) reducing the emission of harmful gas and odors, (3) improving the growth environment inside the pig house, (4) reducing energy costs, (5) improving the farm management and operating system, and 6) improving the livestock product quality. Air recirculation technology can be applied as a technology that can solve these typical problems in the pig industry. An air-recirculated ventilation system can minimize the inflow of air from outdoors and recycle the internal thermal energy of the pig house. The air-recirculated ventilation system consists of (1) an air scrubber module, (2) external air-mixing module, (3) UV cleaning module, (4) solar heat module, and (5) air-distribution module. First, in this study, the field data were collected to analyze the main problems of the target piglet house for the application of the air-recirculated ventilation system. In addition, a computational fluid dynamics (CFD) model was developed and validated for seasonal aerodynamic analysis. The applicability of the air-recirculated ventilation system was evaluated based on the CFD computed results for various environmental conditions. As a result of evaluating the internal environment according to the ventilation rates and external-air-mixing ratio of the air-recirculated ventilation system, the required ventilation rate and external air-mixing ratio to maintain the proper temperature and gas concentration were determined.