Dmitry Bragin

Mr. Dmitry Bragin

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
MPMaria Poltavtseva
Maria Poltavtseva
ASAlexander Shelupanov
Alexander Shelupanov
DBDmitry Bragin
Dmitry Bragin
Dmitry ZegzhdaDmitry Zegzhda
Dmitry Zegzhda
EAElena Alexandrova
Elena Alexandrova
Modern cyber-physical systems (CPS) use digital control of physical processes. This allows attackers to conduct various cyberattacks on these systems. According to the current trends, an information security monitoring system (ISMS) becomes part of a security management system of CPS. It provides information to make a decision and generate a response. A large number of new methods are aimed at CPS security, including security assessment, intrusion detection, and ensuring sustainability. However, as a cyber-physical system operates over time, its structure and requirements may change. The datasets available for the protection object (CPS) and the security requirements have become dynamic. This dynamic effect causes asymmetry between the monitoring data collection and processing subsystem and the presented security tasks. The problem herein is the choice of the most appropriate set of methods in order to solve the security problems of a particular CPS configuration from a particular bank of the available methods. To solve this problem, the authors present a method for the management of an adaptive information security monitoring system. The method consists of solving a multicriteria discrete optimization problem under Pareto-optimality conditions when the available data, methods or external requirements change. The experimental study was performed on an example of smart home intrusion detection. In the study, the introduction of a constraint (a change in requirements) led to the revision of the monitoring scheme and a different recommendation of the monitoring method. As a result, the information security monitoring system gains the property of adaptability to changes in tasks and the available data. An important result from the study is the fact that the monitoring scheme obtained using the proposed management method has a proven optimality under the given conditions. Therefore, the asymmetry between the information security monitoring data collection and processing subsystem and the set of security requirements in cyber-physical systems can be overcome.

29 November 2021 in Computers
Verified
Journal Article
Open access
PDF file
EKEvgeny Kalinin
Evgeny Kalinin
DBDanila Belyakov
Danila Belyakov
DBDmitry Bragin
Dmitry Bragin
AKAnton Konev
Anton Konev
In recent years, a lot of IoT devices, wireless sensors, and smart things contain information that must be transmitted to the server for further processing. Due to the distance between devices, battery power, and the possibility of sudden device failure, the network that connects the devices must be scalable, energy efficient, and flexible. Particular attention must be paid to the protection of the transmitted data. The Bluetooth mesh was chosen as such a network. This network is built on top of Bluetooth Low-Energy devices, which are widespread in the market and whose radio modules are available from several manufacturers. This paper presents an overview of security mechanisms for the Bluetooth mesh network. This network provides encryption at two layers: network and upper transport layers, which increases the level of data security. The network uses sequence numbers for each message to protect against replay attacks. The introduction of devices into the network is provided with an encryption key, and the out-of-band (OOB) mechanism is also supported. At the moment, a comparison has been made between attacks and defense mechanisms that overlap these attacks. The article also suggested ways to improve network resiliency.

21 July 2020 in Journal of the Russian Universities. Radioelectronics
Verified
Journal Article
Open access
PDF file
DBDmitry Bragin
Dmitry Bragin
IPI. V. Pospelova
I. V. Pospelova
ICIrina V. Cherepanova
Irina V. Cherepanova
VSV. N. Serebryakova
V. N. Serebryakova
Introduction. Localization of objects position in closed space plays an important role in many areas of human activity, including medicine. Using indoor-positioning technologies as a part of telemedicine systems allows one to improve the quality of medical care and to reduce mortality of patients. Therefore, indoor-positioning technologies contribute to achieve the goals outlined in the Russian Federation government`s program "Healthcare development". Aim. To study the applicability of modern radiofrequency technologies for localization of patients inside a hospital building. Materials and methods. Scientific sources devoted to indoor-positioning based on radiofrequency technologies were analyzed. The methods used included: - bibliographic retrieval; - selection and verification of sources based on their relevance; - analysis of sources by methods of deconstruction and comparative analysis . Results. The result of the analysis indicated that radiofrequency positioning technologies allow one to locate objects using radio waves properties. The disadvantage of the technology is the penetration of radio signal through walls and floors. Given this, it is necessary to use complex algorithms to detect an object with accuracy to a specific room. Despite this disadvantage, radiofrequency technologies can be used for positioning in medical facilities since they are easy in deployment and service. Also, they are used in ready-made commercial solutions. ZigBee technology is an exception because it does not allow one to track moving objects in real-time. Conclusion. Based on the study it was concluded that BLE technology is the most suitable for indoor-positioning in medical facilities. It is energy-efficient, it has sufficiently fast data transfer rate, good communication radius and a large range of ready-made communication equipment. It is also worth noting that most wireless medical sensors exchange data via the BLE interface.

29 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
IPIrina V. Pospelova
Irina V. Pospelova
ICIrina V. Cherepanova
Irina V. Cherepanova
DBDmitry Bragin
Dmitry Bragin
ISIvan A. Sidorov
Ivan A. Sidorov
EKEvgeny Yu. Kostyuchenko
Evgeny Yu. Kostyuchenko
VSVictoriya N. Serebryakova
Victoriya N. Serebryakova
This research aims to estimate the feasibility of using smart-bracelets as a part of a medicine indoor-positioning system, to monitor the health status and location of patients in a hospital. The smart-bracelet takes on the role of a token of the system and can measure pulse, blood pressure and saturation and provide data transmission over the BLE. The distance between token and anchor was calculated by the RSSI. The position of a token and anchor relative to each other was determined by the trilateration method. The results of the research showed that the accuracy of the developed system in a static position is 1.46 m and exceeds 3 m in a dynamic position. Results of experiments showed that measurements from the smart bracelets are transmitted to the server of the system without distortion. The study results indicated that smart-bracelets could be used to locate patients inside a hospital or estimate their current health state. Given the low accuracy of systolic pressure measurement, it is recommended to develop an algorithm that will allow smooth measuring error for higher-precision estimation of the patient’s general health state. In addition, it is planned to improve the positioning algorithm.

26 January 2023
Verified
Book Chapter
Closed access
PDF file
DBDmitry A. Baranov
Dmitry A. Baranov
ATAlexander Olegovich Terekhin
Alexander Olegovich Terekhin
DBDmitry Bragin
Dmitry Bragin
AMArtur A. Mitsel
Artur A. Mitsel

25 September 2023 in Complex Issues of Cardiovascular Diseases
Verified
Journal Article
Open access
PDF file
ВКВладимир Сергеевич Кавешников
Владимир Сергеевич Кавешников
DBDmitry Bragin
Dmitry Bragin
ВВВалерий Харисович Ваизов
Валерий Харисович Ваизов
АКАртём Владимирович Кавешников
Артём Владимирович Кавешников
МКМария Анатольевна Кузьмичкина
Мария Анатольевна Кузьмичкина
ITIrina Trubacheva
Irina Trubacheva
HighlightsThe review analyzes the studies devoted to the possibility of using machine learning methods to predict the occurrence of atrial fibrillation, cardiovascular risk factors, carotid atherosclerosis, and total cardiovascular risk. The combinations of machine learning methods with mobile, cloud and telemedicine technologies have significant prospects. In the near future, such technologies are expected to be used for atrial fibrillation screening and risk stratification using cardiac imaging data. Based on machine learning methods, mobile preventive technologies are being developed, particularly for nutritional behavior management. AbstractThe article reviews the main directions of machine learning (ML) application in the primary prevention of cardiovascular diseases (CVD) and highlights examples of scientific and practical problems solved with its help. Currently, the possibility of using ML to predict cardiovascular risk, occurrence of atrial fibrillation (AF), cardiovascular risk factors, carotid atherosclerosis, etc. has been studied. The data of questionnaires, medical examination, laboratory indices, electrocardiography, cardio visualization, medications, genomics and proteomics are used in ML models. The most common classifiers are Random Forest, Support Vector, Neural Networks. As compared to traditional risk calculators many ML algorithms show improvement in prediction accuracy, but no evident leader has been defined yet. Deep ML technologies are at the very early stages of development. Mobile, cloud and telemedicine technologies open new possibilities for collection, storage and the use of medical data and can improve CVD prevention. In the near future, such technologies are expected to be used for atrial fibrillation screening as well as cardiovascular risk stratification using cardiac imaging data. Moreover, the addition of them to traditional risk factors provides the most stable risk estimates. There are examples of mobile ML technologies use to manage risk factors, particularly eating behavior. Attention is paid to such problems, as need to avoid overestimating the role of artificial intelligence in healthcare, algorithms’ bias, cybersecurity, ethical issues of medical data collection and use. Practical applicability of ML models and their impact on endpoints are currently understudied. A significant obstacle to implementation of ML technologies in healthcare is the lack of experience and regulation.