In smart farming, both artificial intelligence and robotic systems are applied in order to improve efficiency. In agriculture, for jobs such as seeding, monitoring, and harvesting, robots are widely used. When using robots to harvest fruit and vegetables, it is essential not to apply excessive force, as it may damage the harvest. In this paper, a soft robotic three-fingered gripper is presented. It was designed and analysed using the finite element method. Each finger is made of silicone rubber. The shape of the finger is designed so that it is capable of handling spherical shaped objects, such as tomatoes or oranges. When holding a tomato, the fingers apply the contact force. The fingers are actuated pneumatically and the force applied is also controlled by a micro controller. The pressure inside the air chamber of the finger is in the range of 0- 95 kPa. Force sensors are attached to the end of each finger to provide force feedback. Then, the holding force is adjusted and applied to the surface of the tomato. The gripper can successfully grasp tomatoes with a force less than the bio-yield of the tomatoes 2.57 N.
21 September 2021 in Journal of Mechanisms and Robotics
A compliant gripper with nearly parallel gripping motion is developed by a topology synthesis and a dimensional synthesis approach. The topology synthesis process can generate linkage-type compliant mechanisms. Suitable boundary conditions of the topology synthesis process are selected to achieve the desired functions of the device. The dimensional synthesis is based on an evolutionary optimal design process. To meet various design goals, a nondominated multi-objective genetic algorithm is selected for the optimal design process. A kinetostaic model based on the chained beam constraint model is developed for force–displacement analysis of the designs. Efficiency and accuracy of the design approach are proved by experiments. Appropriate linkage types of compliant mechanisms may be discovered by the topology optimization process before moving on to the dimensional synthesis to obtain final designs.
In this paper, a 3-PRS (prismatic, revolute, and spherical) parallel manipulator for platform stabilization is designed. The main purpose of this device is to stabilize visual equipment, which is placed on top of a car to inspect electrical transmission cables, as part of routine maintenance. Due to the bulky and heavy infrared cameras used during inspections, a stabilizer platform has been designed to handle the weight of camera equipment up to 10 kg. This device consists of two major mechanisms. The first mechanism is able to adjust the angle of the camera. Thus, the user can focus the camera along the electric transmission lines. The second mechanism is stabilization. The mechanism serves to stabilize the orientation and position of the camera in the roll, pitch, and heave directions. To test the performance of the stabilization mechanism, the device is fed with the known value of the angle with regard to the input. As such, the device is trying to compensate for the change in angle. The results show that the errors between the input angles and compensated angles are in the range of 0.4–3%. Errors are seen to be within an acceptable range. It is significant that the resultant errors do not affect the orientation of the camera.
14 April 2025 in Sensors and Actuators A: Physical
This paper sets out to design a device for removing bubbles during the process of hemodialysis. The concept is to guide the bubbles while traveling through the device and eventually the bubbles can be collected. The design focuses on the analysis of various parameters i.e. inlet diameter, inlet velocity and size of the pitch. The initial diameters of Models 1 and 2 have thread regions of 6 and 10 mm, respectively. Parameters: Swirl number, Taylor number, Lift coefficient along with pressure field are also implemented. Based on computational fluid dynamics analysis, the bubbles' average maximum equilibrium position for Model 1 reached 1.995 mm, being greater than that of Model 2, which attained 1.833 mm. Then, 16,000 bubbles were released into Model 1 to validate the performance of the model. This number of bubbles is typically found in the dialysis. Thus, it was found that 81.53% of bubbles passed through the radial region of 2.20 ± 0.30 mm. The appropriate collecting plane was at 100 mm, as measured from the inlet position along the axial axis. The Taylor number, Lift coefficient, and Swirl number proved to be significant parameters for describing the movement of the bubbles. Results were based on multiple inlet velocities. It is seen that Model 3, the improved model with unequal pitch, reached a maximum equilibrium position of 2.24 mm. Overall, results demonstrated that Model 1 was the best design compared to Models 2 and 3. Model 1 was found capable of guiding the bubbles to the edge location and did not generate extra bubbles. Thus, the parametric study, herein, can be used as a prototype for removing bubbles during the process of hemodialysis.