Si Wu

Dr. Si Wu

Beijing Jiaotong University, School of Electrical Engineering, Beijing 100044, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SWSi Wu
Si Wu
Mingli WuMingli Wu
Mingli Wu
LLLinwei Li
Linwei Li
SWSongda Wang
Songda Wang
Kejian SongKejian Song
Kejian Song
YWYi Wang
Yi Wang
As high-speed railways develop rapidly worldwide, the problems of neutral section and power quality are becoming increasingly prominent. These problems affect the normal operation of the power grid and the electric locomotives. The co-phase power supply schemes were proposed by researchers, which can solve these problems well. Among them, the MMC-based scheme (MMC-5 L) is a representative one. The existing scheme, when applied to the auto-transformer (AT)-fed system which is usually adopted by high-speed railways, needs to install an auto-transformer on the output side. To eliminate the auto-transformer and to obtain the more suitable and superior co-phase power supply schemes to AT-fed system, two improved schemes are proposed in this paper based on the novel MMC-based scheme (MMC-6 L) we proposed before. While establishing the mathematical model, creating the control system, and carrying out simulation verification of the proposed schemes, the proposed schemes are compared with MMC-6 L and MMC-5 L in terms of topological characteristics, control system complexity, power loss, and functionality. The results show that while the proposed schemes can fulfill the functions of the co-phase power supply scheme well like the MMC-5 L and MMC-6 L, they are more suitable and superior for the AT-fed system in terms of control system complexity and power loss. Among them, MMC-5L1CB performs best in power loss, and MMC-4L2CB performs best in control system complexity.

5 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
SWSi Wu
Si Wu
Mingli WuMingli Wu
Mingli Wu
YWYi Wang
Yi Wang
The existing problems of the traction power-supply system (i.e., the existence of the neutral section and the power quality problems) limit the development of railways, especially high-speed railways, which are developing rapidly worldwide. The existence of the neutral section leads to the speed loss and traction loss as well as mechanical failures, all of which threaten the fast and safe operation of the train and the system. Meanwhile, the power quality problems (e.g., the negative sequence current, the reactive power, and the harmonic) can bring a series of problems that cannot be ignored on the three-phase grid side. In response, many researchers have proposed co-phase power-supply schemes to solve these two problems simultaneously. Given that the auto-transformer (AT) power-supply mode has become the main power-supply mode for the high-speed railway traction power-supply system, it has a bright future following the rapid development of the high-speed railway. In addition, there is no co-phase power-supply scheme designed for AT power-supply mode in the existing schemes. Therefore, the main contribution of this paper is to propose a specifically designed power-supply mode more suitable for the AT, as well as to establish the control systems for the rectifier side and the inverter side. In addition, for the proposed scheme, the operation principle is analyzed, the mathematical model is built, and the control system is created, and its functionality is verified by simulation, and its advantages are compared and summarized finally. The result proves that it can meet functional requirements. At the same time, compared with the existing co-phase power-supply scheme, it saves an auto-transformer in terms of topology, reduces the current stress by 10.9% in terms of the current stress of the switching device, and reduces the power loss by 0.25% in terms of the entire system power loss, which will result in a larger amount of electricity being saved. All of this makes it a more suitable co-phase power-supply scheme for the AT power-supply mode.