Hyesu Jeon

Dr. Hyesu Jeon


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2015 in Sensors
Verified
Journal Article
Open access
PDF file
HJHyesu Jeon
Hyesu Jeon
WYWook Jae Yoo
Wook Jae Yoo
SSSang Hun Shin
Sang Hun Shin
GKGuwon Kwon
Guwon Kwon
MKMingeon Kim
Mingeon Kim
BLBongsoo Lee
Bongsoo Lee
We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber (PSF) to a plastic optical fiber (POF). To measure the planar dose distribution on a chest phantom according to exposure parameters used in clinical practice, we divided the top of the chest phantom into nine equal parts virtually and then installed the nine sensing probes at each center of the nine equal parts on the top of the chest phantom as measuring points. Each scintillation signal generated in the nine sensing probes was transmitted through the POFs and then intensified by the image intensifier because the scintillation signal normally has a very low light intensity. Real-time scintillation images (RSIs) containing the intensified scintillation signals were taken by the CMOS image sensor with a single lens optical system and displayed through a software program. Under variation of the exposure parameters, we measured RSIs containing dose information using the multichannel all-in-one phantom dosimeter and compared the results with the absorbed doses obtained by using a semiconductor dosimeter (SCD). From the experimental results of this study, the light intensities of nine regions of interest (ROI) in the RSI measured by the phantom dosimeter were similar to the dose distribution obtained using the SCD. In conclusion, we demonstrated that the planar dose distribution including the entrance surface dose (ESD) can be easily measured by using the proposed phantom dosimeter system.

1 February 2014 in The Transactions of The Korean Institute of Electrical Engineers
Verified
Journal Article
Closed access
SHSeunghan Hong
Seunghan Hong
SSSang Hun Shin
Sang Hun Shin
HSHyeok In Sim
Hyeok In Sim
SKSeon Geun Kim
Seon Geun Kim
HJHyesu Jeon
Hyesu Jeon
BLBongsoo Lee
Bongsoo Lee