We have developed a tomographic diffractive microscope, equipped with a fluorescence confocal scanner. We measure experimentally the lateral resolution using an edge method and by comparing tomographic images of the same samples with wide-field and laser scanning confocal microscopy images; a scanning electron microscope image serves as a reference. The experimental resolution is shown to be to about , or . This instrument also permits one to measure 3D, complex index of refraction distributions, a quantity that is not accessible to conventional microscopes, and we show how this feature may be used to observe KCl crystals, absorption of which is very weak.
Microscopy techniques allowing observation of unlabeled samples have recently experienced a regain of interest. In particular, approaches based on recording of the optical field diffracted by the specimen, in amplitude and phase, have proven their capacities for biological investigations. When combined with variations of specimen illumination, tomographic acquisitions are possible. One limitation of previously developed approaches is the anisotropic resolution, characteristic of all transmission microscopes. In this context, an instrument, characterized by isotropic high-resolution 3D imaging capabilities, is still awaited. For the first time, to the best of our knowledge, we have developed tomographic diffractive microscopy combining specimen rotation and illumination rotation, which delivers images with (almost) isotropic resolution below 200 nm. The method is illustrated by observations of nanoscopic fiber tips, microcrystals and pollens, and should be helpful for characterizing freestanding natural (diatoms, spores, red or white blood cells, etc.) or artificial samples.
We report a tomographic diffractive microscope, which permits imaging non-labelled transparent or semi-transparent samples. Based on a combination of microholography with a tomographic illumination, our set-up creates 3-D images of the index of refraction distribution within the sample. One acquires successively interferograms, rotating the illumination (the specimen being static) and using phase-shifting holography. Within the first Born approximation, each interferogram is interpreted as a subset of the Fourier transform of the specimen index of refraction distribution. The reconstruction is therefore similar to synthetic aperture imaging: one recombines the information in the Fourier space, and a final Fourier transform gives a 3-D image of the specimen. First recalling the theoretical foundations, we then describe our experiment, and show initial results obtained on biological samples.
We have developed a tomographic diffractive microscope in reflection, which permits observation of sample surfaces with an improved lateral resolution, compared to a conventional holographic microscope. From the same set of data, high-precision measurements can be performed on the shape of the reflective surface by reconstructing the phase of the diffracted field. Doing so allows for several advantages compared to classical holographic interferometric measurements: improvement in lateral resolution, easier phase unwrapping, reduction of the coherent noise, combined with the high-longitudinal precision provided by interferometric phase measurements. We demonstrate these capabilities by imaging various test samples.