Francesco Epis

Dr. Francesco Epis

2nd Intensive Care Unit, UOC Anestesia e Rianimazione II Cardiopolmonare, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2017 in Canadian Journal of Emergency Medicine
Verified
Journal Article
Closed access
EBEnrico Baldi
Enrico Baldi
stefano cornarastefano cornara
stefano cornara
ECEnrico Contri
Enrico Contri
FEFrancesco Epis
Francesco Epis
DFDario Fina
Dario Fina
Alberto SomaschiniAlberto Somaschini
Alberto Somaschini
Objective: The chances of surviving an out-of-hospital cardiac arrest depend on early and high-quality cardiopulmonary resuscitation (CPR). Our aim is to verify whether the use of feedback devices during laypersons’ CPR training improves chest compression quality. Methods: Laypersons totalling 450 participating in Basic Life Support and Automated External Defibrillation (BLS/AED) courses were randomly divided into three groups: group No Feedback (NF) attended a course without any feedback, group Short Feedback (SF) a course with 1-minute training with real-time visual feedback, and group Long Feedback (LF) a course with 10-minute training with real-time visual feedback. At the end of each course, we recorded 1 minute of compression-only CPR. The primary end point was the difference in the percentage of compressions performed with correct depth. Results: There was a significant improvement in the percentage of compressions with correct depth in the groups receiving feedback compared to the other (NF v. LF, p=0.022; NF v. SF, p=0.005). This improvement was also present in the percentage of compressions with a complete chest recoil (71.7% in NF, 86.6% in SF, and 88.8% in LF; p<0.001), compressions with the correct hand position (93.2% in NF, 98.2% in SF, and 99.3% in LF; p<0.001), and in the Total CPR Score (79.4% in NF, 90.2% in SF, and 92.5% in LF; p<0.001). There were no significant differences for all of the parameters between group SF and group LF. Conclusions: Real-time visual feedback improves laypersons’ CPR quality, and we suggest its use in every BLS/AED course for laypersons because it can help achieve the goals emphasized by the International Liaison Committee on Resuscitation recommendations.

1 September 2017 in The American Journal of Emergency Medicine
Verified
Journal Article
Closed access
ECEnrico Contri
Enrico Contri
stefano cornarastefano cornara
stefano cornara
Alberto SomaschiniAlberto Somaschini
Alberto Somaschini
CDCinzia Dossena
Cinzia Dossena
MTMichela Tonani
Michela Tonani
EBEnrico Baldi
Enrico Baldi

1 March 2018 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
FEFrancesco Epis
Francesco Epis
MBMirko Belliato
Mirko Belliato
During extracorporeal membrane oxygenation (ECMO), oxygen (O2) transfer (V'O2) and carbon dioxide (CO2) removal (V'CO2) are partitioned between the native lung (NL) and the membrane lung (ML), related to the patient's metabolic-hemodynamic pattern. The ML could be assimilated to a NL both in a physiological and a pathological way. ML O2 transfer (V'O2ML) is proportional to extracorporeal blood flow and the difference in O2 content between each ML side, while ML CO2 removal (V'CO2ML) can be calculated from ML gas flow and CO2 concentration at sweep gas outlet. Therefore, it is possible to calculate the ML gas exchange efficiency. Due to the ML aging process, pseudomembranous deposits on the ML fibers may completely impede gas exchange, causing a "shunt effect", significantly correlated to V'O2ML decay. Clot formation around fibers determines a ventilated but not perfused compartment, with a "dead space effect", negatively influencing V'CO2ML. Monitoring both shunt and dead space effects might be helpful to recognise ML function decline. Since ML failure is a common mechanical complication, its monitoring is critical for right ML replacement timing and it also important to understand the ECMO system performance level and for guiding the weaning procedure. ML and NL gas exchange data are usually obtained by non-continuous measurements that may fail to be timely detected in critical situations. A real-time ECMO circuit monitoring system therefore might have a significant clinical impact to improve safety, adding relevant clinical information. In our clinical practise, the integration of a real-time monitoring system with a set of standard measurements and samplings contributes to improve the safety of the procedure with a more timely and precise analysis of ECMO functioning. Moreover, an accurate analysis of NL status is fundamental in clinical setting, in order to understand the complex ECMO-patient interaction, with a multi-dimensional approach.

2 January 2021 in Membranes
Verified
Journal Article
Open access
PDF file
MBMirko Belliato
Mirko Belliato
FEFrancesco Epis
Francesco Epis
LCLuca Cremascoli
Luca Cremascoli
FFFiorenza Ferrari
Fiorenza Ferrari
MQMaria Giovanna Quattrone
Maria Giovanna Quattrone
RLRoberto Lorusso
Roberto Lorusso
Mechanical power (MP) represents a useful parameter to describe and quantify the forces applied to the lungs during mechanical ventilation (MV). In this multi-center, prospective, observational study, we analyzed MP variations following MV adjustments after veno-venous extra-corporeal membrane oxygenation (VV ECMO) initiation. We also investigated whether the MV parameters (including MP) in the early phases of VV ECMO run may be related to the intensive care unit (ICU) mortality. Thirty-five patients with severe acute respiratory distress syndrome were prospectively enrolled and analyzed. After VV ECMO initiation, we observed a significant decrease in median MP (32.4 vs. 8.2 J/min, p < 0.001), plateau pressure (27 vs. 21 cmH2O, p = 0.012), driving pressure (11 vs. 8 cmH2O, p = 0.014), respiratory rate (RR, 22 vs. 14 breaths/min, p < 0.001), and tidal volume adjusted to patient ideal body weight (VT/IBW, 5.5 vs. 4.0 mL/kg, p = 0.001) values. During the early phase of ECMO run, RR (17 vs. 13 breaths/min, p = 0.003) was significantly higher, while positive end-expiratory pressure (10 vs. 14 cmH2O, p = 0.048) and VT/IBW (3.0 vs. 4.0 mL/kg, p = 0.028) were lower in ICU non-survivors, when compared to the survivors. The observed decrease in MP after ECMO initiation did not influence ICU outcome. Waiting for large studies assessing the role of these parameters in VV ECMO patients, RR and MP monitoring should not be underrated during ECMO.

15 October 2020 in ASAIO Journal
Verified
Journal Article
Closed access
MBMirko Belliato
Mirko Belliato
LCLuca Cremascoli
Luca Cremascoli
FEFrancesco Epis
Francesco Epis
FFFiorenza Ferrari
Fiorenza Ferrari
MQMaria G. Quattrone
Maria G. Quattrone
RLRoberto Lorusso
Roberto Lorusso
Veno-venous extracorporeal membrane oxygenation (V-V ECMO) represents a component of the treatment strategy for severe respiratory failure. Clinical evidence on the management of the lung during V-V ECMO are limited just as the consensus regarding timing of weaning. The monitoring of the carbon dioxide (CO2) removal (V′CO2TOT) is subdivided into two components: the membrane lung (ML) and the native lung (NL) are both taken into consideration to evaluate the improvement of the function of the lung and to predict the time to wean off ECMO. We enrolled patients with acute respiratory distress syndrome (ARDS). The V′CO2NL ratio (V′CO2NL/V′CO2TOT) value was calculated based on the distribution of CO2 between the NL and the ML. Of 18 patients, 15 were successfully weaned off of V-V ECMO. In this subgroup, we observed a significant increase in the V′CO2NL ratio comparing the median values of the first and last quartiles (0.32 vs. 0.53, p = 0.0045), without observing any modifications in the ventilation parameters. An increase in the V′CO2NL ratio, independently from any change in ventilation could, despite the limitations of the study, indicate an improvement in pulmonary function and may be used as a weaning index for ECMO.

26 August 2022 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
FEFrancesco Epis
Francesco Epis
LCLiliane Chatenoud
Liliane Chatenoud
Alberto SomaschiniAlberto Somaschini
Alberto Somaschini
IBIlaria Bitetti
Ilaria Bitetti
FCFulvio Cantarero
Fulvio Cantarero
MLMartin Langer
Martin Langer
Sickle-cell disease (SCD) patients are considered to be at high risk from open-heart surgery. This study assessed the role of a simple sickling-prevention protocol. Perioperative non-specific and SCD-specific morbidity and 30-day mortality are investigated in a retrospective cohort study on patients undergoing isolated mitral valve surgery. Patients with and without SCD were compared. In the SCD cohort, a bundle of interventions was applied to limit the risk of sickling: ‘on-demand’ transfusions to keep haemoglobin levels of around 7–8 g/dl, cardiopulmonary bypass (CPB) with higher blood flow and perfusion temperature, close monitoring of acid–base balance and oxygenation. Twenty patients with and 40 patients without SCD were included. At baseline, only preoperative haemoglobin levels differed between cohorts (8.1 vs 11.8 g/dl, P < 0.001). Solely SCD patients received preoperative transfusions (45.0%). Intraoperative transfusions were significantly larger in SCD patients during CPB (priming: 300 vs 200 ml; entire length: 600 vs 300 ml and 20 vs 10 ml/kg). SCD patients had higher perfusion temperatures during CPB (34.7 vs 33.0°C, P = 0.01) with consequently higher pharyngeal temperature, both during cooling (34.1 vs 32.3°C, P = 0.02) and rewarming (36.5 vs 36.2°C, P = 0.02). No mortality occurred, and non-SCD-specific complications were comparable between groups, but one SCD patient suffered from perioperative cerebrovascular accident with seizures, and another had evident haemolysis. SCD patients may undergo open-heart surgery for mitral valve procedures with an acceptable risk profile. Simple but thoughtful perioperative management, embracing ‘on-demand’ transfusions and less-aggressive CPB cooling is feasible and probably efficacious.