Lei Xia

Dr. Lei Xia

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MSMingkui Shen
Mingkui Shen
HJHonghui Jiang
Honghui Jiang
MLMing Luo
Ming Luo
WWWengang Wang
Wengang Wang
NLNing Li
Ning Li
LXLei Xia
Lei Xia
The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p < 0.001), and implant costs ($10,191.0 vs. $13,577.3, p = 0.003) in the LD group. Both low density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs.

27 April 2019 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
MLMing Luo
Ming Luo
WWWengang Wang
Wengang Wang
NYNingning Yang
Ningning Yang
LXLei Xia
Lei Xia
Background: Three-dimensional (3-D) printing offers the opportunity to create patient-specific guides for pedicle screw placement based on CT-generated models. This technology might allow for more-accurate placement of pedicle screws in patients with severe congenital scoliosis who have rotated vertebrae and small pedicles, but to our knowledge, this premise has not been tested. Questions/purposes: (1) Is the use of 3-D printing and pedicle guider technology as or more accurate than the use of the freehand technique for pedicle-screw placement in patients with severe congenital scoliosis? (2) Does surgical time differ with the use of these guiders? (3) Are complications less common in patients treated with this new approach to pedicle-screw placement? Methods: A prospective controlled study was conducted of patients with severe congenital scoliosis (major curve ≥ 90°) from June 2016 to June 2018. During this period, we treated 93 patients with congenital scoliosis; 32 had severe scoliosis with a major curve ≥ 90°. The patients were divided into a pedicle guider group (n = 15) and a control group (n = 17) based on their willingness to use pedicle guider technology, which was considered a research technology. With the numbers available, there were no between-group differences in terms of age, sex, BMI, or parameters related to curve severity or flexibility, and all patients in both groups had severe curves. Preoperative and postoperative low-dose CT scans were performed in the two groups. In the pedicle guider group, custom software was used to design the pedicle guider, and a 3-D printer was used to print a physical spinal model and pedicle guiders. The pedicle guiders were tested on the surface of the physical spinal model before surgery to ensure proper fit, and then used to assist pedicle screw placement during surgery. A total of 244 screws were implanted with the help of 127 pedicle guiders (254 guiding tunnels) during surgery in the PG group. Five predesigned pedicle guiders were abandoned due to an unstable match, and the success rate of assisted screw placement using a pedicle guider was 96% (244 of 254). The freehand technique was used in the control group, which relied on anatomic localization to place pedicle screws. The accuracy of pedicle screw placement was evaluated with CT scans, which revealed whether screws had broken through the pedicle cortex. We compared the groups in terms of accuracy (defined as unanticipated breaches less than 2 mm), surgical time, time to place pedicle screws, and screw-related complications. Results: A higher proportion of the screws placed using pedicle guider technology were positioned accurately than were in the control group (93% [227 of 244] versus 78% [228 of 291]; odds ratio, 3.69 [95% CI, 2.09–6.50]; p<0.001). With pedicle guider use, operative time (296 ± 56 versus 360 ± 74; 95% CI, -111 to -17; p = 0.010), time to place all screws (92 ± 17 versus 118 ± 21; 95% CI, -39 to -12; p = 0.001), and mean time to place one screw (6 ± 1 versus 7 ± 1; 95% CI, -2 to 0; p = 0.011) decreased. One patient in the pedicle guider group and four in the control group experienced screw-related complications; the sample sizes and small number of complications precluded statistical comparisons. Conclusions: In this small, preliminary study, we showed that the accuracy of the surgical technique using spinal 3-D printing combined with pedicle guider technology in patients with severe congenital scoliosis was higher than the accuracy of the freehand technique. In addition, the technique using pedicle guider technology appeared to shorten operative time. If these findings are confirmed in a larger study, pedicle guider technology may be helpful for situations in which intraoperative CT or O-arm navigation is not available. Level of Evidence: Level II, therapeutic study.

1 June 2017 in World Neurosurgery
Verified
Journal Article
Closed access
MLMing Luo
Ming Luo
PWPu Wang
Pu Wang
WWWengang Wang
Wengang Wang
MSMingkui Shen
Mingkui Shen
GXGenzhong Xu
Genzhong Xu
LXLei Xia
Lei Xia

11 July 2016 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
MLMing Luo
Ming Luo
WWWengang Wang
Wengang Wang
MSMingkui Shen
Mingkui Shen
LXLei Xia
Lei Xia
Radiological outcomes between anterior and posterior approach in Lenke 5C curves were still controversial. Meta-analysis on published articles to compare fusion segments and radiological outcomes between the two surgical approaches was performed. Electronic database was conducted for searching studies concerning the anterior versus posterior approach in Lenke 5C curves. After quality assessment, data of means, standard deviations, and sample sizes were extracted. RevMan 5.3 was adopted for data analysis. Seven case-control studies involving 308 Lenke 5C AIS patients were identified in the meta-analysis. No significant differences were noted in correction rate of thoracolumbar/lumbar curve (95 % CI −6.02 to 4.32, P = 0.75) and incidence of proximal junctional kyphosis (95 % CI 0.12 to 7.19, P = 0.94) of final follow-up, in change values of thoracolumbar/lumbar curve (95 % CI −3.28 to 7.19, P = 0.46) and thoracic kyphosis (95 % CI −4.10 to 0.13, P = 0.07). The anterior approach represented a significant shorter fusion segments compared to posterior approach (95 % CI −1.72 to −0.71, P < 0.00001). The posterior approach obtained a larger increasing Cobb angle of lumbar lordosis than the anterior approach (95 % CI −6.06 to −0.61, P = 0.02). The anterior and posterior approach can obtain comparable coronal correction, change values of thoracic kyphosis, and incidence of proximal junctional kyphosis. The anterior approach saves approximate one more fusion segment, and the posterior approach can obtain a larger increasing Cobb angle of lumbar lordosis, from preoperation to final follow-up. The article type of this study is meta-analysis and prospective registration is not required.

1 July 2017 in Medicine
Verified
Journal Article
Open access
PDF file
MLMing Luo
Ming Luo
NLNing Li
Ning Li
MSMingkui Shen
Mingkui Shen
LXLei Xia
Lei Xia
Incidence of complications and reoperations between pedicle screw (PS) and hybrid instrumentations (HI) are still controversial in adolescent idiopathic scoliosis (AIS) patients. A systematic review and meta-analysis were performed to compare overall complications, reoperations, and radiographic outcomes between the 2 constructs. Strictly followed the PRISMA 2009 guidelines, the MEDLINE, EMBASE, and the Cochrane Library databases were used to search for literatures up to April 2016, addressing PS versus HI in AIS patients. The Newcastle–Ottawa scale was adopted to assess the quality of the studies. Data on complications, reoperations, Cobb angle of major curve, thoracic kyphosis, and proximal junctional measurement were extracted from the included studies. RevMan 5.3 and SPSS 21.0 were used for statistical analysis. Twenty-four case-control studies with a total of 3042 AIS patients (1582 PS, 1460 HI) were included, consisting of 1 randomized controlled trial, 1 prospective study, and 22 retrospective studies. Decreased overall complications (95% CI 0.42–0.87, P = .007; I2 = 38%) and reoperations (95% CI 0.22–0.62, P = .0001; I2 = 0%) were found in PS group compared with HI group. As regard to reasons for reoperations, increased incidence of pseudarthrosis (P = .005), dislodged instrumentation (P = .005), and deep infection (P = .016) occurred in HI group. PS group achieved a better coronal correction (95% CI −7.06 to −4.54, P < .00001; I2 = 34%), but HI group was more powerful in restoring thoracic kyphosis (95% CI −7.88 to −3.70, P < .00001; I2 = 60%), and no significant differences were found in proximal junctional measurement (95% CI −0.88 to 1.54, P = .59; I2 = 0%) between the 2 constructs. Compared with hybrid instrumentation, pedicle screw construct provides better coronal correction but less thoracic kyphosis restoring, with decreased incidence of overall complications and reoperations in AIS patients. As regard to the pedicle screw construct, the most common reasons for reoperation are malposition, deep infection, pseudarthrosis, and prominent implant.

1 April 2020 in World Neurosurgery
Verified
Journal Article
Closed access
JWJie Wang
Jie Wang
NYNingning Yang
Ningning Yang
MLMing Luo
Ming Luo
LXLei Xia
Lei Xia
NLNing Li
Ning Li