Objectives: To compare health‐economic aspects of multiple imaging modalities used to monitor renal cysts, the present study evaluates costs and outcomes of patients with Bosniak IIF and III renal cysts detected and followed‐up by either contrast‐enhanced computed tomography (ceCT), contrast‐enhanced magnetic resonance imaging (ceMRI), or contrast‐enhanced ultrasonography (CEUS). Patients and Methods: A simulation using Markov models was implemented and performed with 10 cycles of 1 year each. Proportionate cohorts were allocated to Markov models by a decision tree processing specific incidences of malignancy and levels of diagnostic performance. Costs of imaging and surgical treatment were investigated using internal data of a European university hospital. Multivariate probabilistic sensitivity analysis was performed to confirm results considering input value uncertainties. Patient outcomes were measured in quality‐adjusted life years (QALY), and costs as averages per patient including costs of imaging and surgical treatment. Results: Compared to the ‘gold standard’ of ceCT, ceMRI was more effective but also more expensive, with a resulting incremental cost‐effectiveness ratio (ICER) >€70 000 (Euro) per QALY gained. CEUS was dominant compared to ceCT in both Bosniak IIF and III renal cysts in terms of QALYs and costs. Probabilistic sensitivity analysis confirmed these results in the majority of iterations. Conclusion: Both ceMRI and CEUS can be used as alternatives to ceCT in the diagnosis and follow‐up of intermediately complex cystic renal lesions without compromising effectiveness, while CEUS is clearly cost‐effective. The economic results apply to a large university hospital and must be adapted for smaller hospitals.
18 April 2023 in Ultraschall in der Medizin - European Journal of Ultrasound
Background To investigate the inter- and intraobserver variability in comparison to an expert gold standard of the new and modified renal cyst Bosniak classification proposed for contrast-enhanced ultrasound findings (CEUS) by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) in 2020. Materials and Methods 84 CEUS examinations for the evaluation of renal cysts were evaluated retrospectively by six readers with different levels of ultrasound expertise using the modified Bosniak classification proposed for CEUS. All cases were anonymized, and each case was rated twice in randomized order. The consensus reading of two experts served as the gold standard, to which all other readers were compared. Statistical analysis was performed using Cohen’s weighted kappa tests, where appropriate. Results Intraobserver variability showed substantial to almost perfect agreement (lowest kappa κ=0.74; highest kappa κ=0.94), with expert level observers achieving the best results. Comparison to the gold standard was almost perfect for experts (highest kappa κ=0.95) and lower for beginner and intermediate level readers still achieving mostly substantial agreement (lowest kappa κ=0.59). Confidence of rating was highest for Bosniak classes I and IV and lowest for classes IIF and III. Conclusion Categorization of cystic renal lesions based on the Bosniak classification proposed by the EFSUMB in 2020 showed very good reproducibility. While even less experienced observers achieved mostly substantial agreement, training remains a major factor for better diagnostic performance.
Renal pseudotumors appear as benign cortical hypertrophies and are typically assessed by contrast-enhanced computed tomography or magnetic resonance imaging to rule out malignancy. To investigate whether contrast-enhanced ultrasound (CEUS) can rule out renal neoplasm and thus potentially reduce cross-sectional imaging and further follow-up in these patients. Thirty-two patients with presumption of developmental renal pseudotumor on CEUS between June 2011 and July 2019 were retrospectively analyzed. All patients were examined with a standardized renal US protocol including B-mode, color-coded duplex sonography (CCDS), and CEUS by an experienced radiologist (EFSUMB level 3). Images were retrospectively interpreted in consensus by two highly experienced radiologists. Histopathological reports, cross-sectional imaging findings, and clinical course (treatment response, long-term imaging follow-up) were defined as standard of reference. CEUS correctly identified 8/9 neoplastic lesions and missed one oncocytoma within the 32 included patients. Irregular vessel structure (88.9% vs. 13.0%, P = 0.007) and hyperenhancement (66.6% vs. 17.4%, P = 0.031) on CEUS were more common in neoplasm compared to developmental pseudotumors reaching statistical significance. Compared with the standard of reference, CEUS had 89% sensitivity (95% confidence interval [CI] 57–98), 96% specificity (95% CI 80–99), a positive predictive value of 89% (95% CI 57–98), and a negative predictive value of 96% (95% CI 79–99) for ruling out renal malignancy in developmental pseudotumors. CEUS is a safe and fast method to rule out neoplasm in the diagnostic work-up of renal pseudotumors. In conjunction with B-mode and CCDS, CEUS has the potential to reduce further (invasive) diagnostic procedures.
Obesity and bowel gas are known to impair image quality in abdominal ultrasound (US). The present study aims at identifying individual factors in B-mode US that influence contrast-enhanced US (CEUS) image quality to optimize further imaging workup of incidentally detected focal renal masses. We retrospectively analyzed renal CEUS of focal renal masses ≤ 4 cm performed at our center in 143 patients between 2016 and 2020. Patient and lesion characteristics were tested for their influence on focal and overall image quality assessed by two experienced radiologists using Likert scales. Effects of significant variables were quantified by receiver operating characteristics (ROC) curve analysis with area under the curve (AUC), and combined effects were assessed by binary logistic regression. Shrunken kidney, kidney depth, lesion depth, lesion size, and exophytic lesion growth were found to influence focal renal lesion image quality, and all factors except lesion size also influenced overall image quality. Combination of all parameters except kidney depth best predicted good CEUS image quality showing an AUC of 0.91 (p < 0.001, 95%-CI 0.863–0.958). The B-mode US parameters investigated can identify patients expected to have good CEUS image quality and thus help select the most suitable contrast-enhanced imaging strategy for workup of renal lesions.
12 January 2026 in Ultraschall in der Medizin - European Journal of Ultrasound
Multiparametric ultrasound (MPUS) combines B-mode, Doppler techniques, microvascular imaging, contrast-enhanced ultrasound (CEUS), and elastography, thereby enhancing diagnostic precision across a wide spectrum of scrotal diseases. Developed under the auspices of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB), these guidelines provide evidence-based recommendations for the clinical use of MPUS in scrotal imaging. Based on the framework of the Oxford Centre for Evidence-Based Medicine, this document outlines the diagnostic value of MPUS in acute scrotal pain, trauma, infertility, focal and extratesticular lesions, cryptorchidism, and testicular incidentalomas. The recommendations highlight CEUS as the reference method for vascular assessment and elastography as a complementary tool for tissue characterization. These guidelines aim to standardize MPUS practice and promote its integration in routine scrotal imaging.
20 June 2022 in Ultraschall in der Medizin - European Journal of Ultrasound