Md. Faizul Huq Arif

Mr. Md. Faizul Huq Arif


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2016 in Photonic Sensors
Verified
Journal Article
Open access
PDF file
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
Kawsar AhmedKawsar Ahmed
Kawsar Ahmed
SASayed Asaduzzaman
Sayed Asaduzzaman
AAAbul Kalam Azad
Abul Kalam Azad
This paper proposes a hexagonal photonic crystal fiber (H-PCF) structure with high relative sensitivity for liquid sensing; in which both core and cladding are microstructures. Numerical investigation is carried out by employing the full vectorial finite element method (FEM). The analysis has been done in four stages of the proposed structure. The investigation shows that the proposed structure achieves higher relative sensitivity by increasing the diameter of the innermost ring air holes in the cladding. Moreover, placing a single channel instead of using a group of tiny channels increases the relative sensitivity effectively. Investigating the effects of different parameters, the optimized structure shows significantly higher relative sensitivity with a low confinement loss.

1 February 2017 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
JBJaminul Haque Biddut
Jaminul Haque Biddut
This paper proposes the design and optimization of microstructure optical fiber for liquid sensing applications. A number of propagation characteristics have been compared between two formations of hexagonal cladding of our proposed PCF structure. The core of the proposed PCF structure is designed with two rows of supplementary elliptical air holes. We investigate the performance of the designed PCFs for Ethanol as a liquid sample to be sensed. Numerical analysis is carried out by employing the full vectorial Finite Element Method (FEM) to examine the modal birefringence, confinement loss, relative sensitivity and nonlinear coefficient of the proposed PCF structure

1 February 2019 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
MHMohammad Mobarak Hossain
Mohammad Mobarak Hossain
NINazrul Islam
Nazrul Islam
SKShah Mostafa Khaled
Shah Mostafa Khaled

1 December 2015
Verified
Conference Paper
Closed access
SASayed Asaduzzaman
Sayed Asaduzzaman
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
Kawsar AhmedKawsar Ahmed
Kawsar Ahmed
PDPriyanka Dhar
Priyanka Dhar
A circular photonic crystal fiber (C-PCF) structure is presented in this paper as a chemical sensor where both core and cladding are micro structured. Finite element method (FEM) has been applied to investigate the propagation characteristics of proposed C-PCF structure. Relative sensitivity and Confinement loss are numerically examined and optimized by varying the different parameters of the proposed structure. Finally, it is found that the simple 3 rings C-PCF structure shows higher sensitivity as well as lower confinement loss at the wavelength 1.33μm.

18 August 2022 in Plasmonics
Verified
Journal Article
Closed access
PDF file
NINazrul Islam
Nazrul Islam
MMMohi Uddin Masum
Mohi Uddin Masum
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
SASayed Asaduzzaman
Sayed Asaduzzaman
MRMonoranjon Roy
Monoranjon Roy
MYMohammad Abu Yousuf
Mohammad Abu Yousuf

1 May 2015
Verified
Conference Paper
Closed access
MMMonir Morshed
Monir Morshed
SASayed Asaduzzaman
Sayed Asaduzzaman
MAMd. Faizul Huq Arif
Md. Faizul Huq Arif
Kawsar AhmedKawsar Ahmed
Kawsar Ahmed
This paper presents a simple structure of photonic crystal fiber (PCF) based gas sensors. Gas sensors can be used in gas production facilities for safe measurement. The index guiding properties of two rings circular PCF have been analysed for different wavelength with the variation of the diameters of air holes in core and cladding. Finite-element method has been applied for numerical analysis. At the wavelength λ=1.66μm obtained maximum sensitivity is 13.94% and at the same time the confinement loss of the fiber is 2.74×10 -4 dB/m. The proposed structure is more flexible for its high sensitivity, low confinement loss and simple structure compare to early proposed high sensitivity chemical sensor PCFs with a hollow high index ring defect at the centre.