Yvan Petit

Prof. Yvan Petit

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2003 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SDS. Delorme
S. Delorme
YPYvan Petit
Yvan Petit
JGJ.A. de Guise
J.A. de Guise
HLH. Labelle
H. Labelle
CAC.-E. Aubin
C.-E. Aubin
JDJ. Dansereau
J. Dansereau
This paper presents an in vivo validation of a method for the three-dimensional (3-D) high-resolution modeling of the human spine, rib cage, and pelvis for the study of spinal deformities. The method uses an adaptation of a standard close-range photogrammetry method called direct linear transformation to reconstruct the 3-D coordinates of anatomical landmarks from three radiographic images of the subject's trunk. It then deforms in 3-D 1-mm-resolution anatomical primitives (reference bones) obtained by serial computed tomography-scan reconstruction of a dry specimen. The free-form deformation is calculated using dual kriging equations. In vivo validation of this method on 40 scoliotic vertebrae gives an overall accuracy of 3.3 /spl plusmn/ 3.8 mm, making it an adequate tool for clinical studies and mechanical analysis purposes.

1 November 2011 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
JCJulien Chapleau
Julien Chapleau
FCFanny Canet
Fanny Canet
YPYvan Petit
Yvan Petit
GLG-Yves Laflamme
G-Yves Laflamme
DRDominique M. Rouleau
Dominique M. Rouleau
A universal goniometer is commonly used to measure the elbow’s ROM and carrying angle; however, some authors question its poor intertester reliability. We (1) assessed the validity of goniometric measurements as compared with radiographic measurements in the evaluation of ROM of the elbow and (2) determined the reliability of both. The ROM and carrying angle of 51 healthy subjects (102 elbows) were measured using two methods: with a universal goniometer by one observer three times and on radiographs by two independent examiners. Paired t-test and Pearson’s correlation were used to compare and detect the relationship between mean ROM. The maximal error was calculated according to the Bland and Altman method. The intraclass correlation coefficients (ICC) ranged from 0.945 to 0.973 for the goniometric measurements and from 0.980 to 0.991 for the radiographic measurements. The two methods correlated when measuring the total ROM in flexion and extension. The maximal errors of the goniometric measurement were 10.3° for extension, 7.0° for flexion, and 6.5° for carrying angle 95% of the time. We observed differences for maximum flexion, maximal extension, and carrying angle between the methods. Both measurement methods differ but they correlate. When measured with a goniometer, the elbow ROM shows a maximal error of approximately 10°. The goniometer is a reasonable and simple clinical tool, but for research protocols, we suggest using the radiographic method because of the higher level of precision required.

1 January 2004 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
YPYvan Petit
Yvan Petit
CAC. É. Aubin
C. É. Aubin
HLH. Labelle
H. Labelle

15 February 2014 in Spine
Verified
Journal Article
Closed access
LFLéo Fradet
Léo Fradet
PAPierre-Jean Arnoux
Pierre-Jean Arnoux
JRJean-Philippe Ranjeva
Jean-Philippe Ranjeva
YPYvan Petit
Yvan Petit
VCVirginie Callot
Virginie Callot
Study Design. Measurements of cervical and thoracolumbar human spinal cord (SC) geometry based on in vivo magnetic resonance imaging and investigation of morphological “invariants.” Objective. The current work aims at providing morphological features of the complete in vivo human normal SC and at investigating possible “invariant” parameters that may serve as normative data for individualized study of SC injuries. Summary of Background Data. Few in vivo magnetic resonance image–based studies have described human SC morphology at the cervical level, and similar description of the entire SC only relies on postmortem studies, which may be prone to atrophy biases. Moreover, large interindividual variations currently limit the use of morphological metrics as reference for clinical applications or as modeling inputs. Methods. Absolute metrics of SC (transverse and anteroposterior diameters, width of anterior and posterior horns, cross-sectional SC area, and white matter percentage) were measured using semiautomatic segmentation of high resolution in vivo T2*-weighted transverse images acquired at 3 T, at each SC level, on healthy young (N = 15) and older (N = 8) volunteers. Robustness of measurements, effects of subject, age, or sex, as well as comparison with previously published postmortem data were investigated using statistical analyses (separate analysis of variance, Tukey-HSD, Bland-Altman). Normalized-to-C3 parameters were evaluated as invariants using a leave-one-out analysis. Spinal canal parameters were measured and occupation ratio border values were determined. Results. Metrics of SC morphology showed large intra- and interindividual variations, up to 30% and 13%, respectively, on average. Sex had no influence except on posterior horn width (P < 0.01). Age-related differences were observed for anteroposterior diameter and white matter percentage (P < 0.05) and all postmortem metrics were significantly lower than in vivo values (P < 0.001). In vivo normalized SC area and diameters seemed to be invariants (R2 > 0.74, root-mean-square deviation < 10%). Finally, minimal and maximal occupation ratio were 0.2 and 0.6, respectively. Conclusion. This study presented morphological characteristics of the complete in vivo human SC. Significant differences linked to age and postmortem state have been identified. Morphological “invariants” that could be used to calculate the normally expected morphology accurately, were also identified. These observations should benefit to biomechanical and SC pathology studies. Level of Evidence: N/A

1 February 2003 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CAC.-É. Aubin
C.-É. Aubin
YPYvan Petit
Yvan Petit
ISI.A.F. Stokes
I.A.F. Stokes
FPF. Poulin
F. Poulin
MGM. Gardner-Morse
M. Gardner-Morse
HLH. Labelle
H. Labelle
Scoliosis is a three-dimensional deformation of the spine that can be treated by vertebral fusion using surgical instrumentation. However, the optimal configuration of instrumentation remains controversial. Simulating the surgical maneuvers with personalized biomechanical models may provide an analytical tool to determine instrumentation configuration during the pre-operative planning. Finite element models used in surgical simulations display convergence difficulties as a result of discontinuities and stiffness differences between elements. A kinetic model using flexible mechanisms has been developed to address this problem, and this study presents its use in the simulation of Cotrel-Dubousset Horizon surgical maneuvers. The model of the spine is composed of rigid bodies corresponding to the thoracic and lumbar vertebrae, and flexible elements representing the intervertebral structures. The model was personalized to the geometry of three scoliotic patients (with a thoracic Cobb angle of 45°, 49° and 39°). Binary joints and kinematic constraints were used to represent the rod-implant-vertebra joints. The correction procedure was simulated using three steps: (1) Translation of hooks and screws on the first rod; (2) 90° rod rotation; (3) Hooks and screws look-up on the rod. After the simulation, slight differences of 0-6° were found for the thoracic spine scoliosis and the kyphosis, and of 1-8° for the axial rotation of the apical vertebra and for the orientation of the plane of maximum deformity, compared to the real post-operative shape of the patient. Reaction loads at the vertebra-implant link were mostly below 1000 N, while reaction loads at the boundary conditions (representing the overall action of the surgeon) were in the range 7-470 N and maximum torque applied to the rod was 1.8 Nm. This kinetic modeling approach using flexible mechanisms provided a realistic representation of the surgical maneuvers. It may offer a tool to predict spinal geometry correction and assist in the pre-operative planning of surgical instrumentation of the scoliotic spine.

1 January 2004 in Spine
Verified
Journal Article
Closed access
JMJean-Marc Mac-Thiong
Jean-Marc Mac-Thiong
YPYvan Petit
Yvan Petit
CACarl-Éric Aubin
Carl-Éric Aubin
SDSébastien Delorme
Sébastien Delorme
JDJean Dansereau
Jean Dansereau
HLHubert Labelle
Hubert Labelle
Prospective study to evaluate the association between strap tension and brace interface forces in the treatment of adolescent idiopathic scoliosis using the Boston brace system. To determine the strap tension associated with optimal brace interface forces. Trim lines, pad placement, and areas of relief for the brace are guided by radiographic studies. However, optimal adjustment of strap tension is unclear and remains mostly empirical. Brace interface forces in all regions of the trunk were measured for 41 patients with adolescent idiopathic scoliosis at three standardized strap tensions (20 N, 40 N, and 60 N). The brace interface forces were assessed using a mat made of force-sensing transducers. Equivalent interface pressure for each trunk region was also calculated to estimate the distribution of the interface forces. The brace interface forces and the corresponding effective areas increased along with the strap tension for all patients. For patients with a single right thoracic curve, the interface pressure tended to increase with increasing strap tension. This increase was significant in the left axillary, right thoracic, right pelvic, and sternal regions. For double right thoracic-left lumbar curves, the increase in interface pressure was significant in the left axillary, right pelvic, and sternal regions. However, most of this increase occurred between 20 N and 40 N of strap tension, with only slight increase or even a decrease in interface pressures between 40 N and 60 N. The strap tension should be set as high as possible (up to 60 N) for right thoracic curves. For right thoracic-left lumbar curves, the optimal strap tension was approximately 40 N. However, clinicians should ensure that the prescribed strap tension does not cause excessive skin pressure or affect the compliance with the brace. A side opening in the right lumbar area may improve the effectiveness of the brace for double right thoracic-left lumbar curves, but care must be taken to avoid skin problems at the opening.