Toma-Leonida Dragomir

Prof. Toma-Leonida Dragomir

SRAT, IFAC, IEEE, SRR
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir
Ana-Maria PANAAna-Maria PANA
Ana-Maria PANA
VOValentin Laurențiu Ordodi
Valentin Laurențiu Ordodi
VGVasile Daniel Gherman
Vasile Daniel Gherman
GDGabriela-Alina Dumitrel
Gabriela-Alina Dumitrel
SNSorin N Nanu
Sorin N Nanu
Pollution caused by plastic materials has a great impact on the environment. The biodegradation process is a good treatment solution for common polymers and biodegradation susceptible ones. The present work introduces new insight into the biodegradation process from a mathematical point of view, as it envisions a new empirical model for this complex process. The model is an exponential function with two different time constants and a time delay, which follows the weight loss profile of the polymer during the biodegradation process. Moreover, this function can be generated as the output variable of a dynamic exogenous system described through state equations. The newly developed models displayed a good fit against the experimental data, as shown by statistical indicators. In addition, the new empirical model was compared to kinetics models available in the literature and the correlation coefficients were closest to 1 for the new empirical model in all discussed cases. The mathematical operations were performed in the MATLAB Simulink environment.

12 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CBCorneliu Barbulescu
Corneliu Barbulescu
DCDadiana Caiman
Dadiana Caiman
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir
Monitoring the condition of electrolytic capacitors in practical applications is a topic that has been and remains the subject of much research. This article is part of research in this area. It develops a parameter observer (PO) and proposes its use for the determination of the equivalent capacity and equivalent serial resistance of electrolytic capacitors. The observer is an integral-open-loop type second-order system, the input of which is the voltage at the capacitor terminals measured during a two-stage capacitor’s discharging process through a variable resistor. The PO estimates the so-called time constant of the discharging circuit for each of the two stages from which values the capacitor’s parameters are calculated. The use of PO is illustrated for determining the output capacitor parameters of a buck DC–DC converter. The experiments were performed with two electrolytic capacitors with the nominal values 100 μF and 470 μF. Compared with other monitoring methods that use observers, the proposed observer is faster in tracking error mitigation, e.g., 10−3 s in comparison with 5·10−3 s or more. The low computational volume of the discrete-time PO allows the prospect of implementation in real time.

2 March 2009
Verified
Book Chapter
Closed access
PDF file
SDSanda Dale
Sanda Dale
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir

13 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CBCorneliu Barbulescu
Corneliu Barbulescu
DCDadiana Caiman
Dadiana Caiman
SNSorin N Nanu
Sorin N Nanu
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir
This paper describes the implementation of a parameter observer (PO) intended to estimate the capacitance and equivalent serial resistance of a capacitor (ESR). The implemented observer consists of a dynamic second-order discrete-time system. The input signal of the observer is the voltage at the terminals of the capacitor measured during its discharge across a variable resistance in two steps. The implemented observer can be used in quasi-online or offline mode. The theoretical and experimental supporting materials provide a comprehensive picture of the implementation and conditions of use of the PO. The experimental verification was carried out with a microcontroller with Cortex®-M7 core architecture. The sampling time of the PO was 20 μs, and the estimation of the parameters was obtained before the end of the discharge of the capacitor. In the cases described in the paper, this means approximately 25 ms. Due to the PO’s capabilities (estimation speed, reduced computational complexity and precision)—proved by the experiments carried out on three electrolytic capacitors of 100 μF, 220 μF and 440 μF—the implementation is of interest for several applications, primarily in the field of power electronic applications.

20 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DCDadiana Caiman
Dadiana Caiman
CBCorneliu Barbulescu
Corneliu Barbulescu
SNSorin N Nanu
Sorin N Nanu
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir
The article focuses on devising solutions for monitoring the condition of the filter capacitors of DC-DC converters. The article introduces two novel DC-DC buck converter designs that monitor the equivalent series resistance (ESR) and the capacitance of capacitors using a parameter observer (PO) and simple variable electrical networks (VEN). For the first scheme, the PO processes in real time the voltage at the capacitor terminals during a discharge-charge cycle. For the second scheme, the filtering is performed with two or more capacitors in parallel, and the PO processes the voltage at the terminals of each capacitor during two discharge processes without interrupting the filtering operation of the converter. The paper presents the principles and theoretical support on which the two schemes of DC-DC buck converters are based, design details regarding PO and VEN, as well as experiments performed with each of the schemes. In the experimental schemes, the PO is implemented with a microcontroller, and the parameters of some aluminum electrolytic filter capacitors are calculated in a real-time manner of about 40 ms. The calculation accuracy of the equivalent capacity is very good. Regarding the calculation accuracy of the ESR, it is shown that it depends on the fulfillment of certain ratios between the VEN resistances, on the one hand, as well as between them and the ESR, on the other hand.

3 July 2019 in Studies in Informatics and Control
Verified
Journal Article
Closed access
DCDadiana Caiman
Dadiana Caiman
Toma-Leonida DragomirToma-Leonida Dragomir
Toma-Leonida Dragomir