Matthew B. B. Wheeler

Prof. Matthew B. B. Wheeler

orcid

Research Focus & Metrics

Academic Career Length

48Years (1979-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Biomaterials
Verified
Journal Article
Closed access
JWJoseph R. Woodard
Joseph R. Woodard
AHAmanda J. Hilldore
Amanda J. Hilldore
SLSheeny K. Lan
Sheeny K. Lan
CPC.J. Park
C.J. Park
AWAbby R Whittington
Abby R Whittington
AJAmy J. Wagoner Johnson
Amy J. Wagoner Johnson

8 August 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
TNTan H. Nguyen
Tan H. Nguyen
MKMikhail Eugene Kandel
Mikhail Eugene Kandel
MRMarcello Rubessa
Marcello Rubessa
MWMatthew B. B. Wheeler
Matthew B. B. Wheeler
Gabriel PopescuGabriel Popescu
Gabriel Popescu
Multiple scattering limits the contrast in optical imaging of thick specimens. Here, we present gradient light interference microscopy (GLIM) to extract three-dimensional information from both thin and thick unlabeled specimens. GLIM exploits a special case of low-coherence interferometry to extract phase information from the specimen, which in turn can be used to measure cell mass, volume, surface area, and their evolutions in time. Because it combines multiple intensity images that correspond to controlled phase shifts between two interfering waves, gradient light interference microscopy is capable of suppressing the incoherent background due to multiple scattering. GLIM can potentially become a valuable tool for in vitro fertilization, where contrast agents and fluorophores may impact the viability of the embryo. Since GLIM is implemented as an add-on module to an existing inverted microscope, we anticipate that it will be adopted rapidly by the biological community.

1 May 2010 in Biomaterials
Verified
Journal Article
Closed access
SLSheeny K. Lan Levengood
Sheeny K. Lan Levengood
SPSamantha J. Polak
Samantha J. Polak
MWMatthew B. B. Wheeler
Matthew B. B. Wheeler
AMAaron J. Maki
Aaron J. Maki
SCSherrie G. Clark
Sherrie G. Clark
AJAmy J. Wagoner Johnson
Amy J. Wagoner Johnson

18 March 2004 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SRStephanie Raty
Stephanie Raty
EWEric M. Walters
Eric M. Walters
JDJohn Davis
John Davis
HZHenry Zeringue
Henry Zeringue
DBDavid J. Beebe
David J. Beebe
MWMatthew B. B. Wheeler
Matthew B. B. Wheeler
Microfluidic devices (microchannels) have been fabricated and tested for embryo culture. Three different microfabrication materials (silicon, polydimethylsiloxane (PDMS), and borosilicate) were used to fabricate the microchannels. The objective of this study was to determine if static microchannels permitted culture of mouse embryos to the blastocyst stage. Groups of 10 two-cell ICR × B6SJL/F1 mouse embryos were cultured for 96 hours in 4 different physical culture systems: 1) silicon/borosilicate microchannels, 2) PDMS/borosilicate microchannels, and 3) standard microdrops. Embryos cultured in the silicon/borosilicate and PDMS/borosilicate microchannels exhibited a faster rate of cleavage (P < 0.05), and produced more blastocysts (P < 0.01) than control microdrops. Furthermore, microchannels had a lower percentage of degenerated embryos than control embryos (P < 0.01). The results suggest that the microchannel culture systems may provide a culture environment that more closely mimics the in vivo environment.

1 January 2002 in Theriogenology
Verified
Journal Article
Closed access
DBD. Beebe
D. Beebe
MWMatthew B. B. Wheeler
Matthew B. B. Wheeler
HZH. Zeringue
H. Zeringue
EWE. Walters
E. Walters
SRS. Raty
S. Raty

3 October 2014 in Otolaryngology–Head and Neck Surgery
Verified
Journal Article
Closed access
PDF file
DZDavid A. Zopf
David A. Zopf
AMAnna G. Mitsak
Anna G. Mitsak
CFColleen L. Flanagan
Colleen L. Flanagan
MWMatthew B. B. Wheeler
Matthew B. B. Wheeler
GGGlenn E. Green
Glenn E. Green
SHScott J. Hollister
Scott J. Hollister