Healthy adult horses can balance accumulation and dissipation of body heat to maintain their body temperature between 37.5 and 38.5 °C, when they are in their thermoneutral zone (5 to 25 °C). However, under some circumstances, such as following strenuous exercise under hot, or hot and humid conditions, the accumulation of body heat exceeds dissipation and horses can suffer from heat stress. Prolonged or severe heat stress can lead to anhidrosis, heat stroke, or brain damage in the horse. To ameliorate the negative effects of high heat load in the body, early detection of heat stress and immediate human intervention is required to reduce the horse’s elevated body temperature in a timely manner. Body temperature measurement and deviations from the normal range are used to detect heat stress. Rectal temperature is the most commonly used method to monitor body temperature in horses, but other body temperature monitoring technologies, percutaneous thermal sensing microchips or infrared thermometry, are currently being studied for routine monitoring of the body temperature of horses as a more practical alternative. When heat stress is detected, horses can be cooled down by cool water application, air movement over the horse (e.g., fans), or a combination of these. The early detection of heat stress and the use of the most effective cooling methods is important to improve the welfare of heat stressed horses.
The frequent monitoring of a horse’s body temperature post strenuous exercise is critical to prevent or alleviate exertional heat illness (EHI) from occurring. Percutaneous thermal sensing microchip (PTSM) technology has the potential to be used as a means of monitoring a horse’s body temperature during and post-exercise. However, the accuracy of the temperature readings obtained, and their relationship to core body temperature are dependent on where they are implanted. This study aimed to document the relationship between core body temperature, and temperature readings obtained using PTSM implanted in different muscles, during exercise and post application of different cool-down methods. PTSMs were implanted into the right pectoral, right gluteal, right splenius muscles, and nuchal ligament. The temperatures were monitored during treadmill exercise, and post application of three different cool-down methods: no water application (Wno), water application only (Wonly), and water application following scraping (Wscraping). Central venous temperature (TCV) and PTSM temperatures from each region were obtained to investigate the optimal body site for microchip implantation. In this study, PTSM technology provided a practical, safe, and quick means of measuring body temperature in horses. However, its temperature readings varied depending on the implantation site. All muscle temperature readings exhibited strong relationships with TCV (r = 0.85~0.92, p < 0.05) after treadmill exercise without human intervention (water application), while the nuchal ligament temperature showed poor relationship with TCV. The relationships between TCV and PTSM temperatures became weaker with water application. Overall, however the pectoral muscle temperature measured by PTSM technology had the most constant relationships with TCV and showed the best potential to act as an alternate means of monitoring body temperature in horses for 50 min post-exercise, when there was no human intervention with cold water application.
Accurately measuring body temperature in horses will improve the management of horses suffering from or being at risk of developing postrace exertional heat illness. PTSM has the potential for measuring body temperature accurately, safely, rapidly, and noninvasively. This study was undertaken to investigate the relation between the core body temperature and PTSM temperatures prior to, during, and immediately after exercise. The microchips were implanted into the nuchal ligament, the right splenius, gluteal, and pectoral muscles, and these locations were then compared with the central venous temperature, which is considered to be the “gold standard” for assessing core body temperature. The changes in temperature of each implant in the horses were evaluated in each phase (prior to, during, and immediately postexercise) and combining all phases. There were strong positive correlations ranging from 0.82 to 0.94 (p < 0.001) of all the muscle sites with the central venous temperature when combining all the phases. Additionally, during the whole period, PTSM had narrow limits of agreement (LOA) with central venous temperature, which inferred that PTSM is essentially equivalent in measuring horse body temperature. Overall, the pectoral PTSM provided a valid estimation of the core body temperature.
Orientia tsutsugamushi , the causative agent of scrub typhus, is endemic to the Asia–Pacific region. In South Korea, the Boryong strain is considered dominant; however, nationwide phylogeographic distribution and genetic diversity based on clinical isolates remain incompletely characterized. In this study, 121 O. tsutsugamushi clinical isolates were collected from scrub typhus patients at 11 hospitals across South Korea between 2015 and 2024. Isolates were genotyped using 56-kDa gene sequencing and multilocus sequence typing (MLST) of seven housekeeping genes. Sequence analysis and phylogenetic reconstruction were performed using BLAST, PubMLST, BURST, MEGA11, DnaSP6, and R-based tools. Five 56-kDa genotypes were identified: Boryong (93.4%), Ikeda, Je-cheon, Young-worl, and Yeo-joo. MLST revealed 11 sequence types (STs), including five novel STs. While the Boryong strain and related STs were distributed nationwide, minor strains showed restricted distribution in northern regions. Several isolates sharing the same 56-kDa genotype exhibited different MLST STs, indicating possible recombination or local microevolution. This study provides the first nationwide MLST-based characterization of O. tsutsugamushi in South Korea and demonstrates the dominance of the Boryong strain alongside localized diversity. Our findings underscore the utility of MLST for higher-resolution typing and support the need for continued molecular surveillance to inform regional epidemiology and disease management.
Continuous accurate attainment of the body temperature of foals is important to detect early stages of severe heat stress or fever due to a systemic illness. Among a number of methods to measure body temperature, measuring rectal temperature with a digital thermometer is most frequently used due to being relatively fast and simple method. It is also comparatively accurate and correlates well with the core body temperature. However, this method requires restraining the foal for a few seconds to obtain the temperature, and it can be dangerous for the handling person. Percutaneous thermal sensing microchips (PTSMs) are a means of monitoring the body temperature of horses, which offers a non-invasive, hygienic, quick, and accurate way to measure body temperature and provide an identification number for each individual, once it is implanted. This study tested the hypothesis that PTSM has a strong relationship with a conventional body temperature measurement, i.e., measuring rectal temperature with a digital thermometer of foals during summer seasons. Thirty-two foals in three consecutive foaling seasons (2018, 2019, and 2020 season) were implanted a PTSM into the right pectoral muscle, the right splenius muscle, the right gluteal muscle, and the nuchal ligament as early as two weeks after birth. The four PTSM temperatures, rectal temperature, and climate conditions (air temperature, relative humidity, and wet-bulb globe temperature) were obtained simultaneously during the three summer seasons and paired for comparison analysis. Among the PTSM temperatures, the pectoral muscle had the highest correlation and the least differences with rectal temperature. Using PTSM was safe, easy, and reliable for attaining body temperature in foals.
1 May 2021 in Journal of Equine Veterinary Science