Jordan Ortega

Dr. Jordan Ortega

Industrial Engineering, Universidad de La Laguna, San Cristóbal de La Laguna, Spain
orcid
Medical Technology AI Engineer

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Cognitive Neurodynamics
Verified
Journal Article
Open access
PDF file
KMKevin Martín-Chinea
Kevin Martín-Chinea
Jordan OrtegaJordan Ortega
Jordan Ortega
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
EPE Pereda
E Pereda
JTJ Toledo
J Toledo
LAL Acosta
L Acosta
People with impaired motor function could be helped by an effective brain–computer interface (BCI) based on a real-time electroencephalogram (EEG) and artificial intelligence algorithms. However, current methodologies for interpreting patient instructions from an EEG are not accurate enough to be completely safe in a real-world situation , where a poor decision would place their physical integrity at risk, such as when traveling in an electric wheelchair in a city. For various reasons, such as the low signal-to-noise ratio of portable EEGs or the effects of signal contamination (disturbances due to user movement, temporal variation of the features of EEG signals, etc.), a long short-term memory network (LSTM) (a type of recurrent neural network) that is able to learn data flow patterns from EEG signals could improve the classification of the actions taken by the user. In this paper, the effectiveness of using an LSTM with a low-cost wireless EEG device in real time is tested, and the time window that maximizes its classification accuracy is studied. The goal is to be able to implement it in the BCI of a smart wheelchair with a simple coded command protocol, such as opening or closing the eyes, which could be executed by patients with reduced mobility. Results show a higher resolution of the LSTM with an accuracy range between 77.61 and 92.14% compared to traditional classifiers (59.71%), and an optimal time window of around 7 s for the task done by users in this work. In addition, tests in real-life contexts show that a trade-off between accuracy and response times is necessary to ensure detection.

2 December 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
NMNatalia Arteaga Marrero
Natalia Arteaga Marrero
Abián HernándezAbián Hernández
Abián Hernández
Jordan OrtegaJordan Ortega
Jordan Ortega
JRJuan Ruiz-Alzola
Juan Ruiz-Alzola
Diabetic foot ulcers represent the most frequently recognized and highest risk factor among patients affected by diabetes mellitus. The associated recurrent rate is high, and amputation of the foot or lower limb is often required due to infection. Analysis of infrared thermograms covering the entire plantar aspect of both feet is considered an emerging area of research focused on identifying at an early stage the underlying conditions that sustain skin and tissue damage prior to the onset of superficial wounds. The identification of foot disorders at an early stage using thermography requires establishing a subset of relevant features to reduce decision variability and data misinterpretation and provide a better overall cost–performance for classification. The lack of standardization among thermograms as well as the unbalanced datasets towards diabetic cases hinder the establishment of this suitable subset of features. To date, most studies published are mainly based on the exploitation of the publicly available INAOE dataset, which is composed of thermogram images of healthy and diabetic subjects. However, a recently released dataset, STANDUP, provided data for extending the current state of the art. In this work, an extended and more generalized dataset was employed. A comparison was performed between the more relevant and robust features, previously extracted from the INAOE dataset, with the features extracted from the extended dataset. These features were obtained through state-of-the-art methodologies, including two classical approaches, lasso and random forest, and two variational deep learning-based methods. The extracted features were used as an input to a support vector machine classifier to distinguish between diabetic and healthy subjects. The performance metrics employed confirmed the effectiveness of both the methodology and the state-of-the-art features subsequently extracted. Most importantly, their performance was also demonstrated when considering the generalization achieved through the integration of input datasets. Notably, features associated with the MCA and LPA angiosomes seemed the most relevant.

24 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Jordan OrtegaJordan Ortega
Jordan Ortega
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
Ernesto PeredaErnesto Pereda
Ernesto Pereda
Biometric identification uses person recognition techniques based on the extraction of some of their physical or biological properties, which make it possible to characterize and differentiate one person from another and provide irreplaceable and critical information that is suitable for application in security systems. The extraction of information from the electrical biosignal of the human brain has received a great deal of attention in recent years. Analysis of EEG signals has been widely used over the last century in medicine and as a basis for brain–machine interfaces (BMIs). In addition, the application of EEG signals for biometric recognition has recently been demonstrated. In this context, EEG-based biometric systems are often considered in two different applications: identification (one-to-many classification) and authentication (one-to-one or true/false classification). In this article, we establish a methodology for selecting and reducing the minimum number of EEG sensors necessary to carry out effective biometric identification of individuals. Two methodologies were applied, one based on principal component analysis and the other on the Wilcoxon signed-rank test in order to reduce the number of electrodes. This allowed us to identify, according to the methodology used, the areas of the cerebral cortex that would allow selection of the minimum number of electrodes necessary for the identification of individuals. The methodologies were applied to two databases, one with 13 people with self-collected recordings using low-cost EEG equipment, EMOTIV EPOC+, and another publicly available database with recordings from 109 people provided by the PhysioNet BCI.

17 April 2023 in IET Biometrics
Verified
Journal Article
Open access
Jordan OrtegaJordan Ortega
Jordan Ortega
KMKevin Martín-Chinea
Kevin Martín-Chinea
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
Ernesto PeredaErnesto Pereda
Ernesto Pereda
Brain‐computer interface applications for biometric person identification have increased their interest in recent years since they are potentially more secure and more difficult to counterfeit than traditional biometric techniques. However, it is necessary to consider how brain waves are acquired for this purpose, not only in terms of efficiency but also of practical comfort for the user and the affordability degree of the biosignal acquisition device so that their everyday application can become a realistic possibility. In this context, this paper presents the capabilities of using a non‐expensive wireless electroencephalogram (EEG) device to extract spectral‐related and functional connectivity information of brain activity. The proposed method achieved a sufficient biometric identification with two datasets of 13 and 109 subjects when comparing the performance of a sizeable classification algorithm set. In addition, a novel feature in EEG biometric identification, called asymmetry index, is introduced here. Furthermore, this is the first study in this field to consider the effect of the time‐lapse between different recording sessions on the system's behaviour when using a low‐cost EEG device with identification accuracy rates of up to 100%.

18 February 2025 in IEEE Transactions on Dependable and Secure Computing
Verified
Journal Article
Open access
Jordan OrtegaJordan Ortega
Jordan Ortega
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
Ernesto PeredaErnesto Pereda
Ernesto Pereda
Biometric identification involves using person recognition techniques to extract physical or biological traits. These traits make it possible to characterize and differentiate one person from another and provide crucial and irreplaceable information. Biometric identification based on EEG signals has recently become very interesting because it cannot be falsified and provides proof of life in security applications. An EEG-based biometric system is a complex one from which the defining characteristics of each person are extracted. Still, it is not free of uncertainties and impressions inherent to the measurement technique itself. This paper explores the potential of using a classification based on fuzzy logic in conjunction with a particle swarm optimization algorithm (PSO). The methodology was tested with two databases of 13 and 109 subjects, with results showing that this methodology allows high accuracy ratios of 99%. The study provides evidence of the potential of this approach for practical applications in biometric identification.

1 December 2019
Verified
Book Chapter
Closed access
PDF file
KMKevin Martín-Chinea
Kevin Martín-Chinea
Jordan OrtegaJordan Ortega
Jordan Ortega
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
JTJonay Toledo
Jonay Toledo
EPErnesto Pereda
Ernesto Pereda
LALeopoldo Acosta
Leopoldo Acosta