Yali Xie

Dr. Yali Xie

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LPLili Pan
Lili Pan
YXYali Xie
Yali Xie
HYHuali Yang
Huali Yang
MLMengchao Li
Mengchao Li
BXBao Xilai
Bao Xilai
Run-Wei LiRun-Wei Li
Run-Wei Li
With the merits of high sensitivity, high stability, high flexibility, low cost, and simple manufacturing, flexible magnetic field sensors have potential applications in various fields such as geomagnetosensitive E-Skins, magnetoelectric compass, and non-contact interactive platforms. Based on the principles of various magnetic field sensors, this paper introduces the research progress of flexible magnetic field sensors, including the preparation, performance, related applications, etc. In addition, the prospects of flexible magnetic field sensors and their challenges are presented.

18 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DZDan Zhao
Dan Zhao
WJWeiwei Jia
Weiwei Jia
XFXiaona Feng
Xiaona Feng
HYHuali Yang
Huali Yang
YXYali Xie
Yali Xie
Run-Wei LiRun-Wei Li
Run-Wei Li
Elastic polymer-based conductive composites (EPCCs) are of great potential in the field of flexible sensors due to the advantages of designable functionality and thermal and chemical stability. As one of the popular choices for sensor electrodes and sensitive materials, considerable progress in EPCCs used in sensors has been made in recent years. In this review, we introduce the types and the conductive mechanisms of EPCCs. Furthermore, the recent advances in the application of EPCCs to sensors are also summarized. This review will provide guidance for the design and optimization of EPCCs and offer more possibilities for the development and application of flexible sensors.

16 October 2020 in NPG Asia Materials
Verified
Journal Article
Open access
PDF file
YXYali Xie
Yali Xie
QZQingfeng Zhan
Qingfeng Zhan
YHYong Hu
Yong Hu
XHXiao Hu
Xiao Hu
XCXiaodan Chi
Xiaodan Chi
Run-Wei LiRun-Wei Li
Run-Wei Li
Magnetic anisotropy is a fundamental key parameter of magnetic materials that determines their applications. For ferromagnetic materials, the magnetic anisotropy can be easily detected by using conventional magnetic characterization techniques. However, due to the magnetic compensated structure in antiferromagnetic materials, synchrotron measurements, such as X-ray magnetic linear dichroism, are often needed to probe their magnetic properties. In this work, we observed an imprinted fourfold magnetic anisotropy in the amorphous ferromagnetic layer of FeRh/CoFeB heterostructures. The MOKE and ferromagnetic resonance measurements show that the easy magnetization axes of the CoFeB layer are along the FeRh〈110〉 and FeRh〈100〉 directions for the epitaxially grown FeRh layer in the antiferromagnetic and ferromagnetic states, respectively. The combined Monte Carlo simulation and first-principles calculation indicate that the fourfold magnetic anisotropy of the amorphous CoFeB layer is imprinted due to the interfacial exchange coupling between the CoFeB and FeRh moments from the magnetocrystalline anisotropy of the epitaxial FeRh layer. This observation of imprinting the magnetocrystalline anisotropy of antiferromagnetic materials on easily detected ferromagnetic materials may be applied to probe the magnetic structures of antiferromagnetic materials without using synchrotron methods.

22 May 2024 in Polymers
Verified
Journal Article
Open access
PDF file
YWYubo Wang
Yubo Wang
HYHuali Yang
Huali Yang
YXYali Xie
Yali Xie
BXBao Xilai
Bao Xilai
LPLili Pan
Lili Pan
Run-Wei LiRun-Wei Li
Run-Wei Li
Dielectric elastomers, such as thermoplastic polyurethanes (TPUs), are widely used as the dielectric layer, encapsulation layer, and substrate of flexible and stretchable devices. To construct capacitors and actuators that work stably upon deformation, it has become urgent to investigate the evolution of dielectricity under stress and strain. However, the lack of effective methods for estimating the dielectric constant of elastomers under strain poses a big challenge. This study reports a device for the in situ measurement of the dielectric constant of TPU under strain. It is found that upon stretching TPU to a strain of 400%, its dielectric constant decreases from 8.02 ± 0.01 to 2.88 ± 0.25 (at 1 MHz). In addition, combined Fourier-transform infrared spectroscopy, the X-ray scattering technique, and atomic force microscopy were utilized to characterize the evolution of the microstructure under strain. The investigation under tensile strain reveals a decreased density and average size of polarized hard domains, along with a tendency of the molecular chains to align in parallel with the tensile stress. The evolution of the microstructures results in a reduction in the measured dielectric constant in TPU.

1 February 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
YXYali Xie
Yali Xie
Baomin WangBaomin Wang
Baomin Wang
HYHuali Yang
Huali Yang
Run-Wei LiRun-Wei Li
Run-Wei Li
Magnetic thin films are indispensable in flexible devices, which necessitate methods to fabricate flexible magnetic thin films. In this work, we present a method to fabricate wrinkled FeRh flexible films via a coating and transfer process. The obtained FeRh/PDMS films have random patterns of wrinkles with a mean periodicity of 10 μm. From the curvature dependent magnetic measurements, it can be determined that the magnetic properties of the obtained wrinkled FeRh flexible films are insensitive to flexing up to a radius of curvature of 1.5 mm, making it promising for applications in flexible devices.

17 October 2024 in IEEE Magnetics Letters
Verified
Journal Article
Closed access
MZMengting Zou
Mengting Zou
XBXilai Bao
Xilai Bao
XLXinze Li
Xinze Li
YXYali Xie
Yali Xie
HYHuali Yang
Huali Yang
RLRun-Wei Li
Run-Wei Li
Spin valves have received significant attention in the realm of flexible magnetic materials and devices due to their advantages of rapid response and high integration. Despite these benefits, the practical application of spin valves in wearable devices is constrained by their low stretchability and strain stability under tensile strain. Here, by designing spin valves with zigzag-wrinkled structure, we demonstrated that the magnetotransport properties of our spin valves remained unaffected under 25% biaxial tensile strain, revealing stretchability and strain stability. These outstanding performances are related to the zigzag-wrinkled structure generated after releasing the biaxial pre-strain in PDMS substrates. The flattening of the zigzag wrinkles under biaxial tensile strain releases the direct effect of strain on the metal multilayers, thereby maintaining sensing performances upon stretching. This innovative design paves the way for the development of robust, flexible magnetic devices suitable for wearable technology.