Hyosang Lee

Dr. Hyosang Lee

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Science Robotics
Verified
Journal Article
Closed access
KPK. Park
K. Park
HYH. Yuk
H. Yuk
MYM. Yang
M. Yang
JCJ. Cho
J. Cho
HLHyosang Lee
Hyosang Lee
JKJung Kim
Jung Kim
Human skin perceives physical stimuli applied to the body and mitigates the risk of physical interaction through its soft and resilient mechanical properties. Social robots would benefit from whole-body robotic skin (or tactile sensors) resembling human skin in realizing a safe, intuitive, and contact-rich human-robot interaction. However, existing soft tactile sensors show several drawbacks (complex structure, poor scalability, and fragility), which limit their application in whole-body robotic skin. Here, we introduce biomimetic robotic skin based on hydrogel-elastomer hybrids and tomographic imaging. The developed skin consists of a tough hydrogel and a silicone elastomer forming a skin-inspired multilayer structure, achieving sufficient softness and resilience for protection. The sensor structure can also be easily repaired with adhesives even after severe damage (incision). For multimodal tactile sensation, electrodes and microphones are deployed in the sensor structure to measure local resistance changes and vibration due to touch. The ionic hydrogel layer is deformed owing to an external force, and the resulting local conductivity changes are measured via electrodes. The microphones also detect the vibration generated from touch to determine the location and type of dynamic tactile stimuli. The measurement data are then converted into multimodal tactile information through tomographic imaging and deep neural networks. We further implement a sensorized cosmetic prosthesis, demonstrating that our design could be used to implement deformable or complex-shaped robotic skin.

17 March 2022 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Open access
HLHyosang Lee
Hyosang Lee
HSHuanbo Sun
Huanbo Sun
HPHyunkyu Park
Hyunkyu Park
Gokhan SerhatGokhan Serhat
Gokhan Serhat
BJBernard Javot
Bernard Javot
KKKatherine J. Kuchenbecker
Katherine J. Kuchenbecker
Electrical resistance tomography (ERT) can be used to create large-scale soft tactile sensors that are flexible and robust. Good performance requires a fast and accurate mapping from the sensor's sequential voltage measurements to the distribution of force across its surface. However, particularly with multiple contacts, this task is challenging for both previously developed approaches: physics-based modeling and end-to-end data-driven learning. Some promising results were recently achieved using sim-to-real transfer learning, but estimating multiple contact locations and accurate contact forces remains difficult because simulations tend to be less accurate with a high number of contact locations and/or high force. This paper introduces a modular hybrid method that combines simulation data synthesized from an electromechanical finite element model with real measurements collected from a new ERT-based tactile sensor. We use about 290,000 simulated and 90,000 real measurements to train two deep neural networks: the first (Transfer-Net) captures the inevitable gap between simulation and reality, and the second (Recon-Net) reconstructs contact forces from voltage measurements. The number of contacts, contact locations, force magnitudes, and contact diameters are evaluated for a manually collected multi-contact dataset of 150 measurements. Our modular pipeline's results outperform predictions by both a physics-based model and end-to-end learning.

1 August 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KPKyungseo Park
Kyungseo Park
SKSeunghwan Kim
Seunghwan Kim
HLHyosang Lee
Hyosang Lee
IPInkyu Park
Inkyu Park
JKJung Kim
Jung Kim

11 November 2010 in Water Resources Research
Verified
Journal Article
Open access
PDF file
DBDaniela Balin
Daniela Balin
HLHyosang Lee
Hyosang Lee
MRMichael Rode
Michael Rode
Uncertainty analysis has become an important topic in environmental research. Uncertainty in hydrological modeling, in general, has been studied by investigating mainly the influence of the parameter uncertainty on the uncertainty of the simulated outputs. This paper focuses essentially on the impact of point input uncertainty on fully distributed hydrological modeling and proposes an integrated approach to cope with input and parameter uncertainty. The approach uses Bayesian theory in two steps: first, to compute the uncertainty in input forcing data, and second, to compute the hydrological parameter uncertainty and the uncertainties of a lumped‐error term that include other sources of errors: response errors and model error. The method is applied with a fully distributed model: WaSiM‐ETH. The results show that the methodology proposed here is a valuable tool to assess different sources of uncertainty in hydrological modeling and show the effects of uncertainty in the input forcing when a fully distributed, physically based hydrological model is used.

12 December 2020 in Paladyn
Verified
Journal Article
Open access
PDF file
RBRachael Bevill Burns
Rachael Bevill Burns
HSHasti Seifi
Hasti Seifi
HLHyosang Lee
Hyosang Lee
KKKatherine J. Kuchenbecker
Katherine J. Kuchenbecker
Children with autism need innovative solutions that help them learn to master everyday experiences and cope with stressful situations. We propose that socially assistive robot companions could better understand and react to a child’s needs if they utilized tactile sensing. We examined the existing relevant literature to create an initial set of six tactile-perception requirements, and we then evaluated these requirements through interviews with 11 experienced autism specialists from a variety of backgrounds. Thematic analysis of the comments shared by the specialists revealed three overarching themes: the touch-seeking and touch-avoiding behavior of autistic children, their individual differences and customization needs, and the roles that a touch-perceiving robot could play in such interactions. Using the interview study feedback, we refined our initial list into seven qualitative requirements that describe robustness and maintainability , sensing range , feel , gesture identification , spatial , temporal , and adaptation attributes for the touch-perception system of a robot companion for children with autism. Finally, by utilizing the literature and current best practices in tactile sensor development and signal processing, we transformed these qualitative requirements into quantitative specifications. We discuss the implications of these requirements for future human–robot interaction research in the sensing, computing, and user research communities.

13 July 2021 in Smart Materials and Structures
Verified
Journal Article
Open access
PDF file
HLHyosang Lee
Hyosang Lee
KPKyungseo Park
Kyungseo Park
JKJung Kim
Jung Kim
KKKatherine J. Kuchenbecker
Katherine J. Kuchenbecker
Tactile sensors based on electrical resistance tomography (ERT) provide pressure sensing over a large area using only a few electrodes, which is a promising property for robotic tactile skin. Most ERT-based tactile sensors employ electrodes only on the sensor’s edge to avoid undesirable artifacts caused by electrode contact. The distribution of these electrodes is critical, as electrode location largely determines the sensitive regions, but only a few studies have positioned electrodes in the sensor’s central region to improve the sensitivity. Establishing the use of internal electrodes on a stretchable textile needs further investigation into piezoresistive structure fabrication, measurement strategy, and calibration. This article presents a comprehensive study of an ERT-based tactile sensor with distributed electrodes. We describe key fabrication details of a layered textile-based piezoresistive structure, an iterative method for choosing the current injection pathways that yields pairwise optimal patterns, and a calibration process to account for the spatially varying sensitivity of such sensors. We demonstrate two sample sensors with electrodes located only on the boundary or distributed across the surface, and we evaluate their performance via three methods widely used to test tactile sensing in biological systems: single-point localization, two-point discrimination, and contact force estimation.