Occupational noise exposure accounts for approximately 16% of all disabling hearing losses, but the true value and societal costs may be grossly underestimated because current regulations only identify hearing impairments in the workplace if exposures result in audiometric threshold shifts within a limited frequency region. Research over the past several decades indicates that occupational noise exposures can cause other serious auditory deficits such as tinnitus, hyperacusis, extended high-frequency hearing loss, and poor speech perception in noise. Beyond the audiogram, there is growing awareness that hearing loss is a significant risk factor for other debilitating and potentially life-threatening disorders such as cardiovascular disease and dementia. This review discusses some of the shortcomings and limitations of current noise regulations in the United States and Europe.
1 January 2019 in The International Tinnitus Journal
Many studies have focused on the relationship between hearing loss and Alzheimer’s Disease (AD). The mechanisms and causal relationship of this association are still partially unknown, and several theories have been proposed. The most accredited hypothesis is that peripheral hearing deprivation may lead to social isolation and subsequently to dementia. Another hypothesis supports the role of hearing loss on cortical processing, with an increased assignment of cognitive resources to auditory processing rather than to other cognitive processes; other theories suggest changes in the brain structure following reduced peripheral auditory stimulation, or a common cause to both conditions. These preliminary findings clearly delineate the importance of further research aimed at investigating hearing impairment in AD, to a) allow early detection of people with predisposition to AD, b) improve the quality of life in AD patients with hearing loss and c) possibly prevent the progression of the disease treating the hearing impairment. In this review paper, the authors discuss current evidence on the association between hearing impairment and dementia, the identification of peripheral and central auditory dysfunction in at-risk patients as a potential early indicator of incipient AD, and the clinical aspects and the management of patients with AD and hearing loss
3 December 2020 in Biomedical Physics & Engineering Express
The aim of this work is the dosimetric characterization of a plane parallel ionization chamber under defined beam setups at the CERN Linear Electron Accelerator for Research (CLEAR). A laser driven electron beam with energy of 200 MeV at two different field sizes of approximately 3.5 mm FWHM and approximately 7 mm FWHM were used at different pulse structures. Thereby the dose-per-pulse range varied between approximately 0.2 and 12 Gy per pulse. This range represents approximately conventional dose rate range beam conditions up to ultra-high dose rate (UHDR) beam conditions. The experiment was based on a water phantom which was integrated into the horizontal beamline and radiochromic films and an Advanced Markus ionization chamber was positioned in the water phantom. In addition, the experimental setup were modelled in the Monte Carlo simulation environment FLUKA. In a first step the radiochromic film measurements were used to verify the beamline setup. Depth dose distributions and dose profiles measured by radiochromic film were compared with Monte Carlo simulations to verify the experimental conditions. Second, the radiochromic films were used for reference dosimetry to characterize the ionization chamber. In particular, polarity effects and the ion collection efficiency of the ionization chamber were investigated for both field sizes and the complete dose rate range. As a result of the study, significant polarity effects and recombination loss of the ionization chamber were shown and characterized. However, the work shows that the behavior of the ionization chamber at the laser driven beam line at the CLEAR facility is comparable to classical high dose-per-pulse electron beams. This allows the use of ionization chambers on the CLEAR system and thus enables active dose measurement during the experiment. Compared to passive dose measurement with film, this is an important step forward in the experimental equipment of the facility.
An 8-beam, diffractive coherent beam combiner is phase controlled by a learning algorithm trained while optical phases drift, using a differential mapping technique. Combined output power is stable to 0.4% with 95% of theoretical maximum efficiency, limited by the diffractive element.
3 May 2023 in Physical Review Accelerators and Beams
In this work, nondestructive virtual diagnostics are applied to retrieve the electron beam time of arrival and energy in a relativistic ultrafast electron diffraction (UED) beamline using independently measured machine parameters. This technique has the potential to improve the temporal resolution of pump and probe UED scans. Fluctuations in time of arrival have multiple components, including a shot-to-shot jitter and a long-term drift which can be separately addressed by closed loop feedback systems. A linear-regression-based model is used to fit the beam energy and time of arrival and is shown to be able to predict accurate behavior for both long- and short-time scales. More advanced time-series analysis based on machine learning techniques can be applied to improve this prediction further.
About Me
ENT physician, Department of Sense Organs, Sapienza University of Rome - Policlinico Umberto I
ENT physician, Department of Sense Organs, Sapienza University of Rome - Policlinico Umberto I