Katherine Heimburger Ingram

Dr. Katherine Heimburger Ingram

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2022 in JMIR Formative Research
Verified
Journal Article
Open access
MVMaria Valero
Maria Valero
PPPriyanka Pola
Priyanka Pola
OFOluwaseyi Falaiye
Oluwaseyi Falaiye
KIKatherine Heimburger Ingram
Katherine Heimburger Ingram
Liang ZhaoLiang Zhao
Liang Zhao
Sheikh Iqbal AhamedSheikh Iqbal Ahamed
Sheikh Iqbal Ahamed
Background: Diabetes mellitus is a severe disease characterized by high blood glucose levels resulting from dysregulation of the hormone insulin. Diabetes is managed through physical activity and dietary modification and requires careful monitoring of blood glucose concentration. Blood glucose concentration is typically monitored throughout the day by analyzing a sample of blood drawn from a finger prick using a commercially available glucometer. However, this process is invasive and painful, and leads to a risk of infection. Therefore, there is an urgent need for noninvasive, inexpensive, novel platforms for continuous blood sugar monitoring. Objective: Our study aimed to describe a pilot test to test the accuracy of a noninvasive glucose monitoring prototype that uses laser technology based on near-infrared spectroscopy. Methods: Our system is based on Raspberry Pi, a portable camera (Raspberry Pi camera), and a visible light laser. The Raspberry Pi camera captures a set of images when a visible light laser passes through skin tissue. The glucose concentration is estimated by an artificial neural network model using the absorption and scattering of light in the skin tissue. This prototype was developed using TensorFlow, Keras, and Python code. A pilot study was run with 8 volunteers that used the prototype on their fingers and ears. Blood glucose values obtained by the prototype were compared with commercially available glucometers to estimate accuracy. Results: When using images from the finger, the accuracy of the prototype is 79%. Taken from the ear, the accuracy is attenuated to 62%. Though the current data set is limited, these results are encouraging. However, three main limitations need to be addressed in future studies of the prototype: (1) increase the size of the database to improve the robustness of the artificial neural network model; (2) analyze the impact of external factors such as skin color, skin thickness, and ambient temperature in the current prototype; and (3) improve the prototype enclosure to make it suitable for easy finger and ear placement. Conclusions: Our pilot study demonstrates that blood glucose concentration can be estimated using a small hardware prototype that uses infrared images of human tissue. Although more studies need to be conducted to overcome limitations, this pilot study shows that an affordable device can be used to avoid the use of blood and multiple finger pricks for blood glucose monitoring in the diabetic population.

MGMeghana D Gadgil
Meghana D Gadgil
KIKatherine Heimburger Ingram
Katherine Heimburger Ingram
DADuke Appiah
Duke Appiah
JRJessica Rudd
Jessica Rudd
KWKara Whitaker
Kara Whitaker
EGErica P Gunderson
Erica P Gunderson
Diet quality and protein source are associated with type 2 diabetes, however relationships with GDM are less clear. This study aimed to determine whether prepregnancy diet quality and protein source are associated with gestational diabetes mellitus (GDM). Participants were 1314 Black and White women without diabetes, who had at least one birth during 25 years of follow-up in the Coronary Artery Risk Development in Young Adults (CARDIA) cohort study. The CARDIA A Priori Diet Quality Score (APDQS) was assessed in the overall cohort at enrollment and again at Year 7. Protein source and branched-chain amino acid (BCAA) intake were assessed only at the Year 7 exam (n = 565). Logistic regression analysis was used to determine associations between prepregnancy dietary factors and GDM. Women who developed GDM (n = 161) were more likely to have prepregnancy obesity and a family history of diabetes (p < 0.05). GDM was not associated with prepregnancy diet quality at enrollment (Year 0) (odds ratio [OR]: 1.01; 95% confidence interval [CI] 0.99, 1.02) or Year 7 (odds ratio [OR]: 0.97; 95% confidence interval [CI] 0.94, 1.00) in an adjusted model. Conversely, BCAA intake (OR:1.59, 95% CI 1.03, 2.43) and animal protein intake (OR: 1.06, 95% CI 1.02, 1.10) as a proportion of total protein intake, were associated with increased odds of GDM, while proportion of plant protein was associated with decreased odds of GDM (OR: 0.95, 95% CI 0.91, 0.99). In conclusion, GDM is strongly associated with source of prepregnancy dietary protein intake but not APDQS in the CARDIA study.

6 July 2020 in Obesity
Verified
Journal Article
Closed access
PDF file
JCJanet M. Catov
Janet M. Catov
BSBaiyang Sun
Baiyang Sun
MBMarnie Bertolet
Marnie Bertolet
GSGabrielle G. Snyder
Gabrielle G. Snyder
CLCora E. Lewis
Cora E. Lewis
EGErica P. Gunderson
Erica P. Gunderson

3 May 2017 in International Journal of Obesity
Verified
Journal Article
Open access
PDF file
KIKatherine Heimburger Ingram
Katherine Heimburger Ingram
GHG R Hunter
G R Hunter
JJJ F James
J F James
BGB A Gower
B A Gower
Childbearing is associated with a disproportionate accumulation of visceral fat and an increased risk of metabolic disease. However, it is unknown whether the visceral fat accretion associated with pregnancy modifies a woman’s risk for metabolic disease. The purpose of this study was to test whether the association between abdominal fat and insulin sensitivity differs by parity status in healthy overweight women. Intra-abdominal adipose tissue (IAAT) via CT, body composition by DXA, insulin sensitivity via intravenous glucose tolerance test and minimal model (SI), HOMA-IR, and cardiorespiratory fitness (VO2max) were assessed in 212 non-diabetic, premenopausal, overweight non-Hispanic white and African–American women. Nulliparous women (n=98) were younger, had less IAAT and higher VO2max, but similar SI, HOMA-IR and leg fat, compared to parous (n=114). In nulliparous women, IAAT was negatively associated with SI, controlling for age, race and body fat mass (r=−0.40, P<0.001), but this relationship was attenuated in parous women (r=−0.15, P=0.16). In multiple linear regression analysis, leg fat and IAAT were significant predictors of SI in nulliparous, but not parous women. Results suggest that greater IAAT in parous women does not lead to greater insulin resistance; rather, transient insulin resistance during pregnancy may encourage intra-abdominal fat accumulation that is metabolically benign. This underscores the need to consider parity when assessing cardiometabolic risk.

24 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ACAfnan Crystal
Afnan Crystal
MVMaria Valero
Maria Valero
Valentina NinoValentina Nino
Valentina Nino
KIKatherine Heimburger Ingram
Katherine Heimburger Ingram
Diabetes has emerged as a worldwide health crisis, affecting approximately 537 million adults. Maintaining blood glucose requires careful observation of diet, physical activity, and adherence to medications if necessary. Diet monitoring historically involves keeping food diaries; however, this process can be labor-intensive, and recollection of food items may introduce errors. Automated technologies such as food image recognition systems (FIRS) can make use of computer vision and mobile cameras to reduce the burden of keeping diaries and improve diet tracking. These tools provide various levels of diet analysis, and some offer further suggestions for improving the nutritional quality of meals. The current study is a systematic review of mobile computer vision-based approaches for food classification, volume estimation, and nutrient estimation. Relevant articles published over the last two decades are evaluated, and both future directions and issues related to FIRS are explored.

14 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Mitchell ZaplatoschMitchell Zaplatosch
Mitchell Zaplatosch
JMJuliana Fernandes Filgueiras Meireles
Juliana Fernandes Filgueiras Meireles
JAJaneen Amason
Janeen Amason
Sadaf DabeerSadaf Dabeer
Sadaf Dabeer
BKBrian Kliszczewicz
Brian Kliszczewicz
KIKatherine Heimburger Ingram
Katherine Heimburger Ingram
Background: Multifrequency bioelectrical impedance devices such as the InBody 770 (IB770) offer faster measurements and lower costs compared with other body composition assessments. This study validated measures from IB770 against the deuterium oxide dilution technique (D2O) and DXA and compared a four-compartment (4C) model using total body water (TBW) derived from IB770 compared with D2O. Methods: A total of 55 adult females (mean ± SD, age: 21.1 ± 2.6 years) completed IB770 and DXA scans and the D2O protocol. Lin’s concordance correlation coefficients (CCCs), Bland–Altman analyses, and other equivalence tests evaluated agreement between IB770 and the criterion for measures of fat mass (FM), fat-free mass (FFM), and TBW individually and as part of 4C models. Results: There was substantial agreement between IB770 and D2O for TBW (MD = Mean Difference) (MD = 0.34 L, CCC = 0.98) and between the IB770 and DXA for FM (MD = −0.22 kg, CCC = 0.99). IB770 overestimated FFM compared with DXA (MD = 3.15 kg, CCC = 0.91). Both 4C models had almost perfect agreement for FM (CCC = 0.99), FFM (CCC = 0.99), and body fat percentage (CCC = 0.99). Conclusions: IB770 is valid for assessing TBW and can be used within the context of a 4C model in females.