Norbert Konradt

Dr. Norbert Konradt

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2021 in Membranes
Verified
Journal Article
Open access
PDF file
NKNorbert Konradt
Norbert Konradt
JKJan Gerrit Kuhlen
Jan Gerrit Kuhlen
HRHans-Peter Rohns
Hans-Peter Rohns
BSBirgitt Schmitt
Birgitt Schmitt
UFUwe Fischer
Uwe Fischer
Stefan PanglischStefan Panglisch
Stefan Panglisch
In response to increasingly stringent restrictions for drinking water quality, a parallel operation of two common technologies, low-pressure reverse osmosis (LPRO) and activated carbon filtration (ACF), was investigated in a comprehensive five-month pilot study for the removal of 32 typical trace organic contaminants (TrOCs) from Rhine bank filtrates employing a semi- technical plant. TrOCs have been divided into three groups: polyfluorinated aliphatic compounds; pharmaceuticals, pesticides and metabolites; in addition to volatiles, nitrosamines and aminopolycarboxylic acids, which were also examined. The net pressure behavior, normalized salt passage and rejection of TrOCs by LPRO were investigated and compared with ACF operation. In addition, autopsies from the leading and last membrane modules were performed using adenosine triphosphate (ATP), total organic carbon (TOC), ICP-OES and SEM-EDX techniques. Generally, rather stable LPRO membrane performance with limited membrane fouling was observed. TrOCs with a molecular weight of ≥ 150 Da were completely retained by LPRO, while the rejection of di- and trichloro compounds improved as the filtration progressed. ACF also showed significant removal for most of the TrOCs, but without desalination. Accordingly, the ACF and LPRO can be operated in parallel such that the LPRO permeate and the ACF-treated bypass can be mixed to produce drinking water with adjustable hardness and significantly reduced TrOCs.

28 January 2023 in Water
Verified
Journal Article
Open access
PDF file
NKNorbert Konradt
Norbert Konradt
SDSaskia Dillmann
Saskia Dillmann
JBJennifer Becker
Jennifer Becker
DSDetlef Schroden
Detlef Schroden
HRHans-Peter Rohns
Hans-Peter Rohns
Stefan PanglischStefan Panglisch
Stefan Panglisch
The occurrence of Cr (VI) in drinking water resources in low but toxicologically relevant concentrations requires the development of reliable and industrially applicable separation processes in drinking water treatment. There is little information in the literature on the removal of chromium species at concentrations below 10 µg/L. Therefore, in this study, the removal of chromium in the concentration range ≤10 µg/L was investigated using three separation processes, activated carbon filtration (ACF), reduction/coagulation/filtration (RCF) and low-pressure reverse osmosis (LPRO), in both laboratory- and pilot-scale tests. In ACF treatment, Cr (III) was removed by deep bed filtration over 1.5 m of anthracite at a pH of 7.5 (which was used as a prefilter prior to ACF), while Cr (VI) was removed up to 75% via ACF at a filter bed depth of 2.5 m. Fresh activated carbon (AC) exhibited the highest adsorption capacity for Cr (VI), while reactivated AC had a significantly lower capacity for Cr (VI), which was attributed to calcium and iron deposits. In technical filters, where multiple reactivated activated carbon is used, this led to a low removal rate for Cr (VI). Using the RCF process with Fe (II) dosing in a continuous flow reactor at a specific coagulant dosing ratio, high Cr (VI) removal, down to a concentration of 0.1 µg/L, was achieved within minutes. The subsequent anthracite filtration ensured the complete removal of Fe (III) and Cr (III) precipitates. The RCF process was limited by the oxygen side reaction with Fe (II), which dominated at Cr (VI) concentrations below 1 µg/L. In addition, a four-step LPRO process with concentrate recycling showed effective removal (>99%) of both Cr (III) and Cr (VI) species in raw water as well as a negligible effect of pH in the testing pH range of 5.6 to 8.3 on the Cr (VI) removal. Nevertheless, the water hardness and pH of the LPRO permeate must be increased to make it available as drinking water. The three separation processes were found to be able to meet the expected more stringent future regulations for Cr (VI) level in drinking water. The most suitable technology, however, can be selected with respect to the raw water quality/characteristics, site-specific conditions and the already existing equipment.

8 January 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
DKDaniel Konradt
Daniel Konradt
DSDetlef Schroden
Detlef Schroden
UHUlrich Hagemann
Ulrich Hagemann
MHMarkus Heidelmann
Markus Heidelmann
HRHans-Peter Rohns
Hans-Peter Rohns
NKNorbert Konradt
Norbert Konradt
Oxometalates of vanadium(V), chromium(VI), and manganese(VII) have negative impacts on water resources due to their toxicity. To remove them, the kinetics of 0.04 mM oxometalates in natural and synthetic water were studied using graphene nanoplatelets (GNP). The GNP were dispersible in water and formed aggregates >15 µm that could be easily separated. Within 30 min, the GNP were covered with ~0.4 mg/g vanadium and ~1.0 mg/g chromium as Cr(OH)3. The reaction of 0.04 mM permanganate with 50 mg of GNP resulted in a coverage of 10 mg/g in 5 min, while the maximum value was 300 mg/g manganese as Mn2O3/MnO. TEM showed a random metal distribution on the surfaces; no clusters or nanoparticles were detected. The rate of disappearance in aerated water followed a pseudo second-order adsorption kinetics (PSO) for V(V), a pseudo second-order reaction for Cr(VI), and a pseudo first-order reaction for Mn(VII). For Cr(VI) and Mn(VII), the rate constants were found to depend on the GNP mass. Oxygen sorption occurred with PSO kinetics as a parallel slow process upon contact of GNP with air-saturated water. For thermally regenerated GNP, the rate constant decreased for V(V) but increased for Cr(VI), while no effect was observed for Mn(VII). GNP capacity was enhanced through regeneration for V(V) and Cr(VI); no effect was observed for Mn(VII). The reactions are well-suited for use in water purification processes and the reaction products, GNP, decorated with single metal atoms, are of great interest for the construction of sensors, electronic devices, and for application in single-atom catalysis (SAC).

5 December 2024 in Applied Nano
Verified
Journal Article
Open access
PDF file
NKNorbert Konradt
Norbert Konradt
LSLaura Schneider
Laura Schneider
SBStefan Bianga
Stefan Bianga
DSDetlef Schroden
Detlef Schroden
PJPeter Janknecht
Peter Janknecht
GKGeorg Krekel
Georg Krekel
While microparticles can be removed by a filtration step at a drinking water treatment plant (DWTP), engineered nanoparticles (ENPs), which are widely used in industry, commerce and households, pose a major problem due to their special properties, e.g., size, reactivity and polarity. In addition, many ENPs exhibit toxic potential, which makes their presence in drinking water undesirable. Therefore, this study investigated the removal of ENPs in the laboratory and at a pilot-scale DWTP. Eight ENPs were synthesized and tested for stability in different types of water. Only three of them were stable in natural water: cetyltrimethylammonium bromide-coated gold (CTAB/AuNPs), polyvinylpyrrolidone-stabilized gold and silver nanoparticles (PVP/AuNPs, PVP/AgNPs). Their retention on quartz sand, silica gel and fresh anthracite was low, but CTAB/AuNPs could be retained on fresh river sand and thus should not overcome riverbank filtration, while PVP/AuNPs and PVP/AgNPs showed no retention and may be present in raw water. During ozonation, PVP/AuNPs remained stable while PVP/AgNPs were partially degraded. The advanced oxidation process (AOP) was less effective than ozone. PVP/AgNPs were almost completely retained on the pilot plant anthracite sand filter coated with manganese(IV) oxide and ferrihydrite from raw water treatment. PVP/AuNPs passed the filter with no retention. In contrast to PVP/AuNPs, PVP/AgNPs and CTAB/AuNPs were also retained on activated carbon. The integration of a flocculation step with iron(III) salts can improve ENP removal, with PVP/AuNPs requiring higher flocculant doses than PVP/AgNPs. PVP/AuNPs, in particular, are well-suited for testing the effectiveness of water treatment. Further data on the occurrence of stable ENPs in raw water and their behavior during water treatment are needed to perform a risk assessment and derive the measures.