Tamon Miyake

Dr. Tamon Miyake

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2012 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KYK. Yoshimura
K. Yoshimura
KNK. Nakano
K. Nakano
KOK. Okamoto
K. Okamoto
TMTamon Miyake
Tamon Miyake

8 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TMTamon Miyake
Tamon Miyake
TMTomohito Minakuchi
Tomohito Minakuchi
SSSuguru Sato
Suguru Sato
COChihiro Okubo
Chihiro Okubo
DYDai Yanagihara
Dai Yanagihara
ETEmi Tamaki
Emi Tamaki
Hand-gripping training is important for improving the fundamental functions of human physical activity. Bernstein’s idea of “repetition without repetition” suggests that motor control function should be trained under changing states. The randomness level of load should be visualized for self-administered screening when repeating various training tasks under changing states. This study aims to develop a sensing methodology of random loads applied to both the agonist and antagonist skeletal muscles when performing physical tasks. We assumed that the time-variability and periodicity of the applied load appear in the time-series feature of muscle deformation data. In the experiment, 14 participants conducted the gripping tasks with a gripper, ball, balloon, Palm clenching, and paper. Crumpling pieces of paper (paper exercise) involves randomness because the resistance force of the paper changes depending on the shape and layers of the paper. Optical myography during gripping tasks was measured, and time-series features were analyzed. As a result, our system could detect the random movement of muscles during training.

4 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TMTamon Miyake
Tamon Miyake
SYShintaro Yamamoto
Shintaro Yamamoto
SHSatoshi Hosono
Satoshi Hosono
SFSatoshi Funabashi
Satoshi Funabashi
ZCZhengxue Cheng
Zhengxue Cheng
SSShigeki Sugano
Shigeki Sugano
Gait phase detection, which detects foot-contact and foot-off states during walking, is important for various applications, such as synchronous robotic assistance and health monitoring. Gait phase detection systems have been proposed with various wearable devices, sensing inertial, electromyography, or force myography information. In this paper, we present a novel gait phase detection system with static standing-based calibration using muscle deformation information. The gait phase detection algorithm can be calibrated within a short time using muscle deformation data by standing in several postures; it is not necessary to collect data while walking for calibration. A logistic regression algorithm is used as the machine learning algorithm, and the probability output is adjusted based on the angular velocity of the sensor. An experiment is performed with 10 subjects, and the detection accuracy of foot-contact and foot-off states is evaluated using video data for each subject. The median accuracy is approximately 90% during walking based on calibration for 60 s, which shows the feasibility of the static standing-based calibration method using muscle deformation information for foot-contact and foot-off state detection.

3 December 2023
Verified
Book Chapter
Closed access
PDF file
TMTamon Miyake
Tamon Miyake
YWYushi Wang
Yushi Wang
PYPin-Chu Yang
Pin-Chu Yang
SSShigeki Sugano
Shigeki Sugano

1 April 2021 in Human Movement Science
Verified
Journal Article
Open access
TMTamon Miyake
Tamon Miyake
FAFederica Aprigliano
Federica Aprigliano
SSShigeki Sugano
Shigeki Sugano
SMSilvestro Micera
Silvestro Micera
VMVito Monaco
Vito Monaco
Controlling minimum toe clearance (MTC) is considered an important factor in preventing tripping. In the current study, we investigated modifications of neuro-muscular control underlying toe clearance during steady locomotion induced by repeated exposure to tripping-like perturbations of the right swing foot. Fourteen healthy young adults (mean age 26.4 ± 3.1 years) participated in the study. The experimental protocol consisted of three identical trials, each involving three phases: steady walking (baseline), perturbation, and steady walking (post-perturbation). During the perturbation, participants experienced 30 tripping-like perturbations at unexpected timing delivered by a custom-made mechatronic perturbation device. The temporal parameters (cadence and stance phase%), mean, and standard deviation of MTC were computed across approximately 90 strides collected during both baseline and post-perturbation phases, for all trials. The effects of trial (three levels), phase (two levels: baseline and post-perturbation) and foot (two levels: right and left) on the outcome variables were analyzed using a three-way repeated measures analysis of variance. The results revealed that exposure to repeated trip-like perturbations modified MTC toward more precise control and lower toe clearance of the swinging foot, which appeared to reflect both the expectation of potential forthcoming perturbations and a quicker compensatory response in cases of a lack of balance. Moreover, locomotion control enabled subjects to maintain symmetric rhythmic features during post-perturbation steady walking. Finally, the effects of exposure to perturbation quickly disappeared among consecutive trials.

7 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Abdullah IskandarAbdullah Iskandar
Abdullah Iskandar
MAMohammed Al-Sada
Mohammed Al-Sada
TMTamon Miyake
Tamon Miyake
YSYamen Saraiji
Yamen Saraiji
Osama HalabiOsama Halabi
Osama Halabi
Tatsuo NakajimaTatsuo Nakajima
Tatsuo Nakajima
The COVID-19 pandemic impacted collaborative activities, travel, and physical contact, increasing the demand for real-time interactions with remote environments. However, the existing remote communication solutions provide limited interactions and do not convey a high sense of presence within a remote environment. Therefore, we propose a snake-shaped wearable telexistence robot, called Piton, that can be remotely used for a variety of collaborative applications. To the best of our knowledge, Piton is the first snake-shaped wearable telexistence robot. We explain the implementation of Piton, its control architecture, and discuss how Piton can be deployed in a variety of contexts. We implemented three control methods to control Piton: HM—using a head-mounted display (HMD), HH—using an HMD and hand-held tracker, and FM—using an HMD and a foot-mounted tracker. We conducted a user study to investigate the applicability of the proposed control methods for telexistence, focusing on body ownership (Alpha IVBO), mental and physical load (NASA-TLX), motion sickness (VRSQ), and a questionnaire to measure user impressions. The results show that both the HM and HH provide relevantly high levels of body ownership, had high perceived accuracy, and were highly favored, whereas the FM control method yielded the lowest body ownership effect and was least favored. We discuss the results and highlight the advantages and shortcomings of the control methods with respect to various potential application contexts. Based on our design and evaluation of Piton, we extracted a number of insights and future research directions to deepen our investigation and realization of wearable telexistence robots.