Nasser Alahmeri

Dr. Nasser Alahmeri


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
LALujain Ibrahim Aldosari
Lujain Ibrahim Aldosari
AAAbdulkhaliq Alshadidi
Abdulkhaliq Alshadidi
APAmit Porwal
Amit Porwal
NANasser Alahmeri
Nasser Alahmeri
MMmohammed moaleem
mohammed moaleem
ASAhmed O. Shami
Ahmed O. Shami
Background: The purpose of this study evaluates and compares the effect of surface roughness (Ra) and color stability on computer-aided design/computer-aided manufacturing (CAD/CAM) hybrid resin (Vita Enamic), feldspathic (Vitablocs® Mark II), and lithium disilicate Zirconia (Vita Suprinity) glazed or polished ceramics immersed in hot Arabic Qahwa and cold coffee. Methods: A total of 96 standardized samples were prepared from CAD/CAM restorative materials. Half of the samples were polished as per the manufacturer’s instructions using a porcelain polishing kit, and the other half were glazed. Samples were distributed and immersed in hot Arabian Qahwa and cold coffee followed by thermocycling. Ra measurements and color changes were conducted before and after immersion. SEM images were captured from each type of glazed or polished ceramic. One-way ANOVA paired Student’s t-test, and Bonferroni test were conducted to detect significant difference between the groups. P > 0.05 was a significant level. Results: Of all the tested samples, Ra increased without any significant difference; however, mean color changes (ΔE*) showed significant differences. An increase in Ra was noted for all the glazed and polished samples after immersion and thermocycling. However, differences were significant only in VM II. In addition, ΔE* was significant only in Vita Suprinity (VS) samples. For immersion groups, significant Ra changes were noticed in glazed samples, only in Vita Enamic (VE) with no ΔE*. In polished samples, mean Ra changes were observed in VM II and VS samples. Significant differences were also noticed in polished VE and VS subgroups of ΔE*. Conclusions: Ra affects all the tested samples, providing higher values on the polished specimens. The ΔE* caused by hot Arabic Qahwa and cold coffee on glazed or polished CAD/CAM restorative materials were clinically acceptable.

13 May 2020 in Medicina
Verified
Journal Article
Open access
PDF file
MMmohammed moaleem
mohammed moaleem
RARashad AlSanosy
Rashad AlSanosy
NANasser Alahmeri
Nasser Alahmeri
MSMansoor Shariff
Mansoor Shariff
AAAbdulkhaliq Alshadidi
Abdulkhaliq Alshadidi
Asaad KhalidAsaad Khalid
Asaad Khalid
Background and Objectives: Khat chewing is considered as a daily habit that is practiced by more than five million people globally. The effect of khat chewing on the surface roughness and the color stability of natural teeth and the material used in the fabrication of dental prosthesis remains unknown. This study was conducted to explore and compare the effect of khat homogenate (KH) on the surface roughness (Ra) and the average color changes (ΔE*) amongst natural teeth and selected shades from different porcelain types, namely, feldspathic metal ceramic (MC) VM13, computer-aided design/computer assisted manufacture (CAD/CAM) feldspathic (Vitablocs Mark II), and multilayer zirconia (Ceramill Zolid PS) porcelains. Materials and Methods: Seventy samples were prepared from natural teeth, feldspathic MC, CAD/CAM Vitablocs Mark II, and zirconia porcelain. The Ra values were measured using a profilometer and expressed in micrometers, whereas the ΔE* values were measured using VITA Easyshade® V spectrophotometer for all samples before and after frequent immersion and thermocycling in KH for 30 days. The surface topography was used to assess the materials surfaces (glazed or polished) after KH immersion by using a white light interferometry machine. Results: Results revealed that the Ra and the ΔE* values of the different types of tested porcelain were influenced by KH. The order of surface roughness values was glazed or polished MC > polished Zircon > polished Vitablocs Mark II > natural teeth. The lowest ΔE* values were recorded for glazed Vitablocs Mark II and MC, and the values could be arranged as polished zircon > natural teeth > glazed zircon > polished MC > polished Vitablocs Mark II. P values were significantly varied (0.05) for both Ra and ΔE*. Conclusions: KH significantly affected both surface parameter and color of glazed or polished porcelain materials and natural teeth.

NANasser Alahmeri
Nasser Alahmeri
MAMaram A. Alahmari
Maram A. Alahmari
MMmohammed moaleem
mohammed moaleem
RARaghad S. A. Alshahrani
Raghad S. A. Alshahrani
FAFatimah F. Alqahtani
Fatimah F. Alqahtani
Agron MetoAgron Meto
Agron Meto
This study aimed to evaluate the effect of three oral hygiene tools, a regular toothbrush, an electronic toothbrush, and mouthwash, on the color stability of three different computer-aided design (CAD) and computer-aided manufactured (CAM) ceramic blocks. Feldspathic ceramic (Vita Triluxe Forte), hybrid resin ceramic (Vita Enamic), and lithium disilicate glass-ceramic (IPS e.max CAD) were used in this study. A CAD/CAM system and 81 (27 of each material) samples of ceramic blocks were used. All samples were immersed in black coffee for 15 days, and the coffee was changed twice per day. Using a spectrophotometer probe, samples on a grey background were scanned, and physical properties like surface hardness and depth were measured using interferometry and a 3D non-contact surface metrology. After 30 days of application of oral hygiene tools, instruments were used to measure various physical, mechanical, and optical properties. Vita Triluxe had the highest average color variation values (ΔE00) after 15 and 30 days of immersion in coffee in both regular and electronic toothbrushes. Moreover, IPS e.max CAD had the least ΔE00 values with no significant differences among the groups. The surface roughness (Ra) of the Vita Enamic ceramic increased when using a regular toothbrush, and the surface height (Rz) for the Vita Enamic ceramic increased when an electronic toothbrush was used. IPS e.max CAD had the greatest modules of elasticity forces, and Vita Triluxe Forte had the lowest when used with a regular toothbrush. The ΔE00 values of the tested materials were minimally increased or decreased after 30 days of cleaning, and all were clinically acceptable. Ra and Rz were the highest for Vita Enamic in comparison to the other groups. The highest percentage in IPS e.max CAD was associated with a type 1 fracture, whereas type 3 was predominantly observed with Vita Enamic, and type 2 in the Vita Triluxe group without significant differences.

Verified
Journal Article
Open access
PDF file
NANasser Alahmeri
Nasser Alahmeri
This study aimed to evaluate how acidic and alkaline staining solutions affect the optical properties (mean color change, ΔE*), geometric characteristics (surface roughness, Ra), and bacterial adhesion of zirconia Ceramill Zolid PS computer-aided design/computer-aided manufacture (CAD/CAM) material after 21 days of immersion. Ninety-six zirconia CAD/CAM Ceramill Zolid multilayer PS specimens were prepared and allocated to eight groups based on the pH values of the immersion solutions; the acidic solutions included Mirinda Citrus, CodeRed, yerba mate tea, Saudi coffee, and Nescafe (A–E), and the alkaline solutions included artificial saliva, DZRT (tobacco-free nicotine pouches), and smokeless tobacco (F–H). The specimens were immersed for 21 days at 37 °C, with the solutions replaced every 12 h to ensure consistency. Color changes were measured using a VITA Easyshade V spectrophotometer, and Ra was evaluated via white-light interferometric microscopy. The bacterial adhesion of Streptococcus mutans was quantified by counting colony-forming units (CFUs, CFU/mm2). Statistical analyses included the Shapiro–Wilk test for normality, one-way ANOVA with Tukey’s HSD post hoc test for group comparisons, and paired t-tests, with significance set at <0.05. The recorded pH values of the staining materials ranged from acidic (Mirinda Citrus: 3.23) to alkaline (smokeless tobacco: 8.54). Smokeless tobacco caused the most unacceptable mean color change (ΔE* = 6.84), followed by DZRT (ΔE* = 6.46), whereas artificial saliva produced the least discoloration (ΔE* = 2.15), with statistically significant differences among the solutions (p < 0.001). The Ra measurements varied significantly (p < 0.001), with Nescafe demonstrating the lowest value (0.486 µm) and DZRT the highest (0.748 µm). S. mutans adhesion was the highest for CodeRed (546.75 CFU) and the lowest for smokeless tobacco (283.92 CFU), demonstrating significant variation across groups (ANOVA, p < 0.001). The acidic and alkaline solutions significantly altered the optical properties, Ra, and bacterial adhesion of zirconia Ceramill Zolid PS CAD/CAM, with acidic solutions leading to higher bacterial adhesion.

1 April 2018 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
NANasser Alahmeri
Nasser Alahmeri
Aim and background: This case report describes a 74-year-old female patient whose teeth were rehabilitated using telescopic crowns (TCs) on abutments and fixed dental prostheses (FDPs) in the maxillary arch with the aid of computer-assisted design and computer-assisted manufacturing (CAD/CAM) technology. The mandibular arch was restored using casted removable dental prostheses (RDPs) and surveyed crowns. Case report: The treatment sequences were followed as recommended in the dental literature. First, existing defective restorations were eliminated, caries was removed, and excellent mouth preparation was performed. Subsequently, root canal treatments and post and core placements were conducted. The casts were mounted, and a new vertical dimension was established. Maxillary telescopic FDP and mandibular prostheses were fabricated. Finally, a regular and proper follow-up and maintenance program was implemented. Conclusion: The patient was satisfied with the esthetics and function of the telescopic FDP in the presence of the established occlusion. Clinical significance: The secondary coping of the telescopic FDP is cemented with temporary cement, which can be changed easily whenever it is loose. Furthermore, it is completely opposed to RDP in the mandibular posterior masticatory area. The prognoses will be good improvement; the patient was medically fit, motivated, and followed continual oral hygiene protocol. Keywords: Computer-assisted design, Computer-assisted manufacturing, Esthetic, Maxilla, Telescopic crown.