Nicolas Ducros

Dr. Nicolas Ducros

University of Lyon, CREATIS Laboratory, UMR 5220 U1206, Lyon, France

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2016 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
FRFlorian Rousset
Florian Rousset
Nicolas DucrosNicolas Ducros
Nicolas Ducros
AFAndrea Farina
Andrea Farina
GVGianluca Valentini
Gianluca Valentini
CDCosimo D'ANdrea
Cosimo D'ANdrea
FPFrancoise Peyrin
Francoise Peyrin
Single-pixel camera imaging is an emerging paradigm that allows high-quality images to be provided by a device only equipped with a single point detector. A single-pixel camera is an experimental setup able to measure the inner product of the scene under view—the image—with any user-defined pattern. Postprocessing a sequence of point measurements obtained with different patterns permits to recover spatial information, as it has been demonstrated by state-of-the-art approaches belonging to the compressed sensing framework. In this paper, a new framework for the choice of the patterns is proposed together with a simple and efficient image recovery scheme. Our goal is to overcome the computationally demanding $\ell _1$ -minimization of the compressed sensing. We propose to choose patterns among a wavelet basis in an adaptive fashion, which essentially relies onto the prediction of the significant wavelet coefficients’ location. More precisely, we adopt a multiresolution strategy that exploits the set of measurements acquired at coarse scales to predict the set of measurements to be performed at a finer scale. Prediction is based on a fast cubic interpolation in the image domain. A general formalism is given so that any kind of wavelets can be used, which enables one to adjust the wavelet to the type of images related to the desired application. Both simulated and experimental results demonstrate the ability of our technique to reconstruct biomedical images with improved quality compared with compressive-sensing-based recovery. Application to the real-time fluorescence imaging of biological tissues could benefit from the proposed method.

13 September 2017 in Medical Physics
Verified
Journal Article
Open access
PDF file
Nicolas DucrosNicolas Ducros
Nicolas Ducros
JAJuan Felipe Pérez-Juste Abascal
Juan Felipe Pérez-Juste Abascal
BSBruno Sixou
Bruno Sixou
SRSimon Rit
Simon Rit
FPFrançoise Peyrin
Françoise Peyrin
Purpose: Exploiting the x‐ray measurements obtained in different energy bins, spectral computed tomography (CT) has the ability to recover the 3‐D description of a patient in a material basis. This may be achieved solving two subproblems, namely the material decomposition and the tomographic reconstruction problems. In this work, we address the material decomposition of spectral x‐ray projection images, which is a nonlinear ill‐posed problem.Methods: Our main contribution is to introduce a material‐dependent spatial regularization in the projection domain. The decomposition problem is solved iteratively using a Gauss–Newton algorithm that can benefit from fast linear solvers. A Matlab implementation is available online. The proposed regularized weighted least squares Gauss–Newton algorithm (RWLS‐GN) is validated on numerical simulations of a thorax phantom made of up to five materials (soft tissue, bone, lung, adipose tissue, and gadolinium), which is scanned with a 120 kV source and imaged by a 4‐bin photon counting detector. To evaluate the method performance of our algorithm, different scenarios are created by varying the number of incident photons, the concentration of the marker and the configuration of the phantom. The RWLS‐GN method is compared to the reference maximum likelihood Nelder–Mead algorithm (ML‐NM). The convergence of the proposed method and its dependence on the regularization parameter are also studied.Results: We show that material decomposition is feasible with the proposed method and that it converges in few iterations. Material decomposition with ML‐NM was very sensitive to noise, leading to decomposed images highly affected by noise, and artifacts even for the best case scenario. The proposed method was less sensitive to noise and improved contrast‐to‐noise ratio of the gadolinium image. Results were superior to those provided by ML‐NM in terms of image quality and decomposition was 70 times faster. For the assessed experiments, material decomposition was possible with the proposed method when the number of incident photons was equal or larger than 105 and when the marker concentration was equal or larger than 0.03 g·cm−3.Conclusions: The proposed method efficiently solves the nonlinear decomposition problem for spectral CT, which opens up new possibilities such as material‐specific regularization in the projection domain and a parallelization framework, in which projections are solved in parallel.

11 April 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
FRFlorian Rousset
Florian Rousset
Nicolas DucrosNicolas Ducros
Nicolas Ducros
FPFrançoise Peyrin
Françoise Peyrin
GVGianluca Valentini
Gianluca Valentini
CDCosimo D’aNdrea
Cosimo D’aNdrea
AFAndrea Farina
Andrea Farina
Time-resolved multispectral imaging has many applications in different fields, which range from characterization of biological tissues to environmental monitoring. In particular, optical techniques, such as lidar and fluorescence lifetime imaging, require imaging at the subnanosecond scales over an extended area. In this paper, we demonstrate experimentally a time-resolved multispectral acquisition scheme based on single-pixel imaging. Single-pixel imaging is an emerging paradigm that provides low-cost high-quality images. Here, we use an adaptive strategy that allows acquisition and image reconstruction times to be reduced drastically or full basis scans. Adaptive time-resolved multispectral imaging scheme can have significant applications in biological imaging, at scales from macroscopic to microscopic.

1 February 2021 in IEEE Access
Verified
Journal Article
Open access
JAJuan Felipe Pérez-Juste Abascal
Juan Felipe Pérez-Juste Abascal
Nicolas DucrosNicolas Ducros
Nicolas Ducros
VPValeriya Pronina
Valeriya Pronina
SRSimon Rit
Simon Rit
PRPierre-Antoine Rodesch
Pierre-Antoine Rodesch
FPFrancoise Peyrin
Francoise Peyrin
The state-of-the art for solving the nonlinear material decomposition problem in spectral computed tomography is based on variational methods, but these are computationally slow and critically depend on the particular choice of the regularization functional. Convolutional neural networks have been proposed for addressing these issues. However, learning algorithms require large amounts of experimental data sets. We propose a deep learning strategy for solving the material decomposition problem based on a U-Net architecture and a Sim2Real transfer learning approach where the knowledge that we learn from synthetic data is transferred to a real-world scenario. In order for this approach to work, synthetic data must be realistic and representative of the experimental data. For this purpose, numerical phantoms are generated from human CT volumes of the KiTS19 Challenge dataset, segmented into specific materials (soft tissue and bone). These volumes are projected into sinogram space in order to simulate photon counting data, taking into account the energy response of the scanner. We compared projection- and image-based decomposition approaches where the network is trained to decompose the materials either in the projection or in the image domain. The proposed Sim2Real transfer strategies are compared to a regularized Gauss-Newton (RGN) method on synthetic data, experimental phantom data and human thorax data.

3 August 2010 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
CDCosimo D'Andrea
Cosimo D'Andrea
Nicolas DucrosNicolas Ducros
Nicolas Ducros
ABAndrea Bassi
Andrea Bassi
SASimon Arridge
Simon Arridge
GVGianluca Valentini
Gianluca Valentini
A method to perform fast 3-D optical reconstruction, based on structured light, in thick samples is demonstrated and experimentally validated. The experimental and reconstruction procedure, based on Finite Elements Method, used to reconstruct absorbing heterogeneities, with arbitrary arrangement in space, is discussed. In particular we demonstrated that a 2D sampling of the source Fourier plane is required to improve the imaging capability.

23 January 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Nicolas DucrosNicolas Ducros
Nicolas Ducros
ABAndrea Bassi
Andrea Bassi
GVGianluca Valentini
Gianluca Valentini
GCGianfranco L. Canti
Gianfranco L. Canti
SASimon R. Arridge
Simon R. Arridge
CDCosimo D'Andrea
Cosimo D'Andrea
In recent years, an increasing effort has been devoted to the optimization of acquisition and reconstruction schemes for fluorescence molecular tomography (FMT). In particular, wide-field structured illumination and compression of the measured images have enabled significant reduction of the data set and, consequently, a decrease in both acquisition and processing times. FMT based on this concept has been recently demonstrated on a cylindrical phantom with a rotating-view scheme that significantly increases the reconstruction quality. In this work, we generalize the rotating-view scheme to arbitrary geometries and experimentally demonstrate its applicability to murine models. To the best of our knowledge this is the first time that FMT based on a rotating-view scheme with structured illumination and image compression has been applied to animals. Ducros, Bassi, Valentini, Canti, Arridge, and D’Andrea: Fluorescence molecular tomography of an animal model using structured light rotating view acquisition Optical molecular imaging is an emerging technique that relies on smart probes with high affinity for specific biomolecules to visualize molecular processes in living organisms.1 While the sensitivity of optical molecular imaging is very high, spatial resolution is limited due to the light scattering of biological tissue. Notwithstanding this physical constraint, fluorescence molecular tomography (FMT), by modeling light scattering in biological tissues, allows one to localize and quantify the three-dimensional (3-D) distribution of specific fluorochromes in small animals, e.g., mice.2 The basic scheme of FMT requires one to illuminate the sample with near infrared light and to acquire the fluorescence signal exiting the sample. Then, by solving an inverse problem, the fluorochrome concentration in all the voxels of the sample can be reconstructed. In order to increase the information content of the acquired data set, a strategy consisting in dense raster-scanning of the excitation light and oversampling of the fluorescence signal all over the animal surface is generally adopted. It is worth stressing that both the position/shape of the inclusion and fluorochrome concentration are biologically relevant, e.g., for tumor localization and to visualize the expression and the activity of specific molecules, respectively, and the two aspects are inherently interlinked; in fact, the quantification capability of FMT strongly depends on its spatial resolution. Recent technological developments have made available high performance detection systems, which allow one to acquire a huge amount of data, such as fluorescence intensity, spectra, polarization state and lifetime. Since much of this data is redundant, there is a need for the optimization of the acquisition and reconstruction schemes, in order to preserve the data information content, while reducing both acquisition and processing time. It is worth stressing that this represents a fundamental step towards the routine use of FMT in biological laboratories. In the last few years, different research groups have proposed the use of wide-field structured illumination3 4. 5. 6. – 7 and/or image compression8 9. – 10 to strongly reduce the size of the data set. Both approaches share the same physical basis: they assume that biological tissue behaves as a low pass filter for the propagation of spatial frequencies. In particular, the authors have proposed a rotating view, i.e., fully tomographic, FMT scheme based on compression in both illumination and detection spaces with well-chosen wavelet bases. This approach was recently experimentally demonstrated on a cylindrical phantom.9 In this work, we generalize this novel scheme and experimentally demonstrate its applicability to a murine model. To the best of our knowledge, this is the first time that FMT based on a rotating-view scheme and compression of the illumination and detection spaces has been applied to an animal model. Moreover, we present the significant upgrades of the experimental procedure necessary to deal with rotating arbitrary geometries, such as the case with animals. The experimental set-up basically consists of an illumination and detection system. The illumination system is based on a laser diode emitting at 630 nm with a power ∼10  mW, a digital micromirror device (DMD) to create the pattern, and an objective lens to project the selected pattern on the sample surface. The detection system consists of a low noise 16-bit cooled charge-coupled device (CCD) camera, which allows one to acquire the light exiting from a large area of the sample surface at the fluorescence and excitation wavelength, according to the detection filter. The sample is placed on a rotational stage to acquire the signal from multiple views. A more detailed description of the set-up can be found in Ref. 11. Measurements have been carried out on both biological tissue mimicking phantoms and an ex vivo nude mouse. The phantom is an epoxy resin cylinder with elliptical section (longer axis 22.4 mm, shorter axis 19.9 mm, height 45 mm, μa=0.02  mm−1, and μs′=1.35  mm−1) with 2 cylindrical holes filled with Nile Blue dye at a concentration of 30 μM, shown in Fig. 1. The mouse was euthanized and gently tied to a frame and held in vertical position. Then, a cylindrical inclusion (2 mm ∅, 10 mm long) filled with a diluted solution of Nile Blue was inserted in the abdomen by microsurgery, beneath the muscular layers. The position of the inclusion is approximately known from the surgery sign and mouse anatomical atlas. <!-- named anchor --> Fig. 1 (a) Phantom concentration. (b) Reconstructed concentration, using 12 views with a step of 30 deg and 8 patterns per view. Slices are displayed every 1.5 mm from z=13.75  mmto z=−14.75  mm. Concentrations are given in arbitrary units. The scheme of the experimental and reconstruction procedures is shown in Fig. 2. Dealing with irregular/asymmetric shapes as in the case of animals, a light propagation model for such geometries is required and two specific problems have to be faced. The first issue consists of obtaining the object volume to be meshed and provided to the propagation model. The second issue consists of determining the portion of the surface that should be illuminated for each view of the object. The two problems can be addressed optically using the described system based on DMD and CCD. It is worth stressing that, even if other methods12 can be used to acquire the shape of the object, the proposed method is extremely effective because it does not require any extra device. First, the animal was illuminated by a wide field beam larger than the object and its shadow is acquired at a fine step angle, typically 1 deg. By applying the inverse Radon transform on the stack of shadows, the 3-D volume of the sample could be reconstructed. The whole procedure requires the sample to be convex along the rotational plane (x, y). This condition can be satisfied by limiting the measurement volume to the thorax and the abdomen. Then, the 3-D volume was used for creating a mesh of tetrahedral finite elements. In this work the iso2mesh mesh generation toolbox has been used.13 The selection of the area to be illuminated for each of the views used for fluorescence measurement requires special care and an adaptive approach. In fact, considering a wide area generally leads to very high transmitted intensity at the excitation wavelength close to the outline of the mouse body where the tissues are thinner. This leads to the saturation of the camera and, hence, to a poor exploitation of its dynamic range. On the other hand, a small illumination area reduces the total excitation power and diminishes the effectiveness of the structured light approach. In practice, the shadow images corresponding to the desired views were segmented, e.g., by applying a threshold, to recover the area corresponding to the animal position. The largest rectangle inscribed within the obtained area was retained as the illumination area. <!-- named anchor --> Fig. 2 Scheme of the acquisition and reconstruction procedures. In a second phase, fluorescence measurements were carried out at 8 different views taken at steps of 45 deg using several illumination patterns, typically 8, for each view. In particular, Haar wavelets patterns were chosen and mapped within each of the rectangular illumination areas previously obtained. The measured fluorescence images were compressed to a few relevant components, here 128 components per image in a Daubechies D4 basis, for both speeding up reconstruction and limiting memory requirement without sacrificing reconstruction quality. In order to increase the spatial resolution of the reconstruction, the virtual source approach was adopted.11 It basically consists in using a linear combination of illumination patterns, and the related fluorescence images, to recreate the response to both positive and negative illuminations. As a first step of reconstruction, the sensitivity matrix (Jacobian) is computed by multiplying together direct photon density fields for the illumination patterns and adjoint fields for the wavelet detection patterns. Next, the reconstructed fluorochrome distribution is obtained from a Tikhonov-regularized linear reconstruction step that involves the measured data and the sensitivity matrix. The details of the reconstruction algorithm are provided in Ref. 11. In order to quantify the performance of the system, preliminary measurements have been carried out by rotating the elliptical phantom about 5 mm off axis. Both conditions (non symmetric shape and off-axis rotation) have been chosen to recreate more realistic circumstances compared to simple cylindrical phantoms. Fluorochrome reconstruction, shown in Fig. 1, has been carried out by using 12 views with steps of 30 deg and eight illumination patterns for each view. The mesh of the phantom, which consists of 13,174 nodes and 78,113 elements, has been obtained in less than a minute. The generation of the illumination patterns adapted to the different views required about 2 min. The regular grid chosen for reconstruction has a voxel size of Δx×Δy×Δz=0.5 ×0.5×0.75  mm3. Good fidelity concerning the localization and dimensions of the inclusions can be observed. Considering the slice at z=16  mm, the reconstructed sections of the fluorescent inclusions have a full-width-half-maximum (FWHM) radius of about 2.3 and 2.6 mm, for left and right tube, respectively. These values compare well to the real size of 1.5 mm. Moreover, the distance between the centers of the two inclusions is about 10.3 mm in good agreement with the true value of 9.4 mm. In order to quantify the reconstruction quality, we computed the performance metrics of reconstruction error (ε) and contrast-to-noise ratio (CNR) previously used for reconstruction on a cylindrical phantom rotating on axis.11 We obtained an ε of −10.0  dB and a CNR of 2.18. Both results are comparable with the values obtained in the cylindrical case.11 In order to further reduce the dimension of the data set, the reconstruction has been repeated by using only six views with a step of 60 deg, and a similar reconstruction error of -10.6 dB and CNR of 1.98 have been obtained. Following the results on phantoms and previous work,11 mouse measurements have been carried out considering eight views with a step of 45 deg and eight illumination patterns for each view. The mesh consisted of 13,452 nodes and 80,361 elements and was computed in about 90 s. The generation of the illumination patterns that are adapted to the desired eight views has required about 2 min. The regular grid chosen for reconstruction has a voxel size of Δx×Δy×Δz=0.5 ×0.5×0.75  mm3. Figure 3 shows the fluorochrome reconstruction for the murine model. <!-- named anchor --> Fig. 3 Fluorochrome reconstruction of murine model considering 8 views and 8 illumination patterns per view. (a) 28 slices are displayed every 0.75 mm along z, from z=8.75  mm to z=−11.50  mm. (b) 3-D rendering showing the isovolume at 35% of the maximum concentration value. Concentrations are given in arbitrary units. The fluorescent inclusion can be well localized in the abdominal region. To quantify its dimensions, we first estimated the position of the center of the reconstructed inclusion. It is found to be at x=−1.5  mm, y=−1.5  mm, and z=3.25  mm. Next, the sections of the reconstructed inclusion are measured in the slice at z=−3.25  mm. A FWHM of 4.9 mm is obtained along the x-axis and of 3.2 mm along the y-axis. The length of the reconstructed inclusion is measured the same way along the z-axis and a FWHM of 10.5 mm is obtained. Both sections and length show a good agreement with the actual dimensions, 2 and 10 mm, respectively. Artifacts are observed on the surface of the animal, which is a recurring issue that can be alleviated by regularizing with spatial priors.14 Nevertheless, the main artifacts are confined to the animal surface, while the biological structures of interest are expected deeper in the tissue. Finally, it is worth discussing the acquisition and reconstruction times. The whole data set used for mouse reconstruction consists of 64 fluorescence images (eight patterns×eight views). The acquisition time for each fluorescence image is 20 s, resulting in a total acquisition time of about 21 min. The reconstruction time, by using a personal computer with a 2.4 GHz processor and 4 gigabytes RAM, is about 2 min. The measurements reported in this paper have been carried out by using a laser power which is well below the maximum permissible exposure (MPE) for the skin, which is 0.2   W/cm2 according to IEC60825 (Ref. 15). One relevant advantage of using a wide-field illumination scheme is represented by the possibility to significantly increase the illumination power, while preserving the power density below the safety limits. By assuming a 10- to 50- fold possible increase of the laser power, an analogous reduction in the acquisition time is expected. In conclusion, an FMT scheme based on structured-light and rotating-view acquisition has been experimentally demonstrated on a mouse. By exploiting structured light and image compression techniques, the acquisition and reconstruction times have been drastically reduced while preserving the spatial resolution of the reconstruction. Future work will be devoted to further reduce the measurement and processing time by improving the light delivery system and using parallel algorithms. Moreover, the experimental setup will be redesigned in order to keep the mouse lying horizontal and to avoid the rotation of the animal. Another important aspect is represented by the selection of the number of views and illumination patterns in order to reduce the acquisition time and increase the spatial resolution. Both parameters depend on several factors such as the geometry/dimensions of the object and optical properties, hence an adaptive approach tailored on the specific sample should improve the performance of the system. <!-- named anchor --> Acknowledgments This work was partially supported by MIUR under the project Futuro in Ricerca (RBFR08XH0H 002) and Royal Society International Joint Project 2009/R2. <!-- named anchor --> <!-- named...