Facundo Carmona

Dr. Facundo Carmona

Instituto de Hidrología de Llanuras Dr. Eduardo J. Usunoff, Universidad Nacional del Centro de la Provincia de Buenos Aires, Pinto 399, Tandil 7000, Argentina
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in ISPRS Journal of Photogrammetry and Remote Sensing
Verified
Journal Article
Closed access
MHMauro E. Holzman
Mauro E. Holzman
Facundo CarmonaFacundo Carmona
Facundo Carmona
RRRaúl Rivas
Raúl Rivas
Raquel NiclosRaquel Niclos
Raquel Niclos

23 April 2013 in Theoretical and Applied Climatology
Verified
Journal Article
Closed access
PDF file
Facundo CarmonaFacundo Carmona
Facundo Carmona
RRRaúl Rivas
Raúl Rivas
VCVicente Caselles
Vicente Caselles

1 October 2019 in Advances in Water Resources
Verified
Journal Article
Closed access
QZQiuru Zhang
Qiuru Zhang
LSLiangsheng Shi
Liangsheng Shi
MHMauro Holzman
Mauro Holzman
MYMing Ye
Ming Ye
YWYakun Wang
Yakun Wang
Yuanyuan ZhaYuanyuan Zha
Yuanyuan Zha

1 January 2015 in European Journal of Remote Sensing
Verified
Journal Article
Open access
Facundo CarmonaFacundo Carmona
Facundo Carmona
RRRaúl Rivas
Raúl Rivas
DFDiana C. Fonnegra
Diana C. Fonnegra

1 January 2017 in MethodsX
Verified
Journal Article
Open access
MHMauro Holzman
Mauro Holzman
RRRaúl Rivas
Raúl Rivas
Facundo CarmonaFacundo Carmona
Facundo Carmona
Raquel NiclosRaquel Niclos
Raquel Niclos
Optimization of field techniques is crucial to ensure high quality soil moisture data. The aim of the work is to present a sampling method for undisturbed soil and soil water content to calibrated soil moisture probes, in a context of the SMOS (Soil Moisture and Ocean Salinity) mission MIRAS Level 2 soil moisture product validation in Pampean Region of Argentina. The method avoids soil alteration and is recommended to calibrated probes based on soil type under a freely drying process at ambient temperature. A detailed explanation of field and laboratory procedures to obtain reference soil moisture is shown. The calibration results reflected accurate operation for the Delta-T thetaProbe ML2x probes in most of analyzed cases (RMSE and bias ≤ 0.05 m3/m3). Post-calibration results indicated that the accuracy improves significantly applying the adjustments of the calibration based on soil types (RMSE ≤ 0.022 m3/m3, bias ≤ -0.010 m3/m3). •A sampling method that provides high quality data of soil water content for calibration of probes is described.•Importance of calibration based on soil types.•A calibration process for similar soil types could be suitable in practical terms, depending on the required accuracy level.