Alex Gustschin

Mr. Alex Gustschin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2021 in Optica
Verified
Journal Article
Open access
AGAlex Gustschin
Alex Gustschin
MRMirko Riedel
Mirko Riedel
KTKirsten Taphorn
Kirsten Taphorn
CPChristian Petrich
Christian Petrich
WGWolfgang Gottwald
Wolfgang Gottwald
JHJulia Herzen
Julia Herzen
Two-dimensional (2D) Talbot array illuminators (TAIs) were designed, fabricated, and evaluated for high-resolution high-contrast x-ray phase imaging of soft tissue at 10–20 keV. The TAIs create intensity modulations with a high compression ratio on the micrometer scale at short propagation distances. Their performance was compared with various other wavefront markers in terms of period, visibility, flux efficiency, and flexibility to be adapted for limited beam coherence and detector resolution. Differential x-ray phase contrast and dark-field imaging were demonstrated with a one-dimensional, linear phase stepping approach yielding 2D phase sensitivity using unified modulated pattern analysis (UMPA) for phase retrieval. The method was employed for x-ray phase computed tomography reaching a resolution of 3 µm on an unstained murine artery. It opens new possibilities for three-dimensional, non-destructive, and quantitative imaging of soft matter such as virtual histology. The phase modulators can also be used for various other x-ray applications such as dynamic phase imaging, super-resolution structured illumination microscopy, or wavefront sensing.

4 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TNTobias Neuwirth
Tobias Neuwirth
ABAlexander Backs
Alexander Backs
AGAlex Gustschin
Alex Gustschin
SVSimon Vogt
Simon Vogt
FPFranz Pfeiffer
Franz Pfeiffer
MSMichael Schulz
Michael Schulz
Neutron grating interferometry (nGI) is a unique technique allowing to probe magnetic and nuclear properties of materials not accessible in standard neutron imaging. The signal-to-noise ratio of an nGI setup is strongly dependent on the achievable visibility. Hence, for analysis of weak signals or short measurement times a high visibility is desired. We developed a new Talbot-Lau interferometer using the third Talbot order with an unprecedented visibility (0.74) over a large field of view. Using the third Talbot order and the resulting decreased asymmetry allows to access a wide correlation length range. Moreover, we have used a novel technique for the production of the absorption gratings which provides nearly binary gratings even for thermal neutrons. The performance of the new interferometer is demonstrated by visualizing the local magnetic domain wall density in electrical steel sheets when influenced by residual stress induced by embossing. We demonstrate that it is possible to affect the density of the magnetic domain walls by embossing and therefore to engineer the guiding of magnetic fields in electrical steel sheets. The excellent performance of our new setup will also facilitate future studies of dynamic effects in electric steels and other systems.

21 June 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
WNWolfgang Noichl
Wolfgang Noichl
FMFabio De Marco
Fabio De Marco
KWKonstantin Willer
Konstantin Willer
TUTheresa Urban
Theresa Urban
MFManuela Frank
Manuela Frank
FPFranz Pfeiffer
Franz Pfeiffer
Grating-based X-ray phase-contrast and in particular dark-field radiography are promising new imaging modalities for medical applications. Currently, the potential advantage of dark-field imaging in early-stage diagnosis of pulmonary diseases in humans is being investigated. These studies make use of a comparatively large scanning interferometer at short acquisition times, which comes at the expense of a significantly reduced mechanical stability as compared to tabletop laboratory setups. Vibrations create random fluctuations of the grating alignment, causing artifacts in the resulting images. Here, we describe a novel maximum likelihood method for estimating this motion, thereby preventing these artifacts. It is tailored to scanning setups and does not require any sample-free areas. Unlike any previously described method, it accounts for motion in between as well as during exposures.

21 May 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
NGNikolai Gustschin
Nikolai Gustschin
AGAlex Gustschin
Alex Gustschin
PMPascal Meyer
Pascal Meyer
MVManuel Viermetz
Manuel Viermetz
PRPhilipp Riederer
Philipp Riederer
FPFranz Pfeifferark
Franz Pfeifferark
Here we report on a non-destructive, spatially resolving and easy to implement quality and parameter control method for high aspect ratio X-ray absorption gratings. Based on angular X-ray transmission measurements, our proposed technique allows to determine the duty cycle, the transmittance, the height, as well as the local inclination of the absorbing grating structures. A key advantage of the presented method is a fast and extensive grating quality evaluation without the need of implementing an entire grating interferometer. In addition to the local and surface-based analysis using a scanning electron microscope, our non-destructive method provides global averaged macroscopic and spatially resolved grating structure information without the requirement of resolving individual grating lines.

12 December 2018 in Production Engineering
Verified
Journal Article
Closed access
PDF file
SVSimon Vogt
Simon Vogt
TNTobias Neuwirth
Tobias Neuwirth
BSBenedikt Schauerte
Benedikt Schauerte
HWHannes Alois Weiss
Hannes Alois Weiss
PFPeter Markus Falger
Peter Markus Falger
WVWolfram Volk
Wolfram Volk

1 October 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
AGAlex Gustschin
Alex Gustschin
TNTobias Neuwirth
Tobias Neuwirth
ABA. Backs
A. Backs
MSMichael Schulz
Michael Schulz
FPF. Pfeiffer
F. Pfeiffer
The imaging performance of a neutron-based Talbot-Lau interferometer depends to a great extent on the absorption characteristics of the source and analyzer gratings. Due to its high neutron attenuation, gadolinium (Gd) is the preferred material for grating fabrication, but suffers from difficulties with deposition time, stability, uniformity, and selectivity into high aspect ratio structures. Here we present a simple alternative method of Gd deposition into grating structures based on metallic particle suspension casting and subsequent doctor-blading. Surface analysis by confocal and electron scanning microscopy shows that a nearly clear, particle free silicon interface of the grating structure over a large area could be reached. Additionally, characterization by neutron radiography confirms a high effective Gd height and homogeneity over the whole grating area. In particular, grating trenches well below 10 μm width could be successfully filled with Gd and deliver excellent absorbing performance down to the sub-2 Å wavelength range. The findings confirm that we obtained an effective binary absorption profile for the fabricated gratings which is of great benefit for grating-based neutron imaging.