Viscoelastic properties of mouse brain tissue were estimated non-invasively, in vivo, using magnetic resonance elastography (MRE) at 4.7 T to measure the dispersive properties of induced shear waves. Key features of this study include (i) the development and application of a novel MR-compatible actuation system which transmits vibratory motion into the brain through an incisor bar, and (ii) the investigation of the mechanical properties of brain tissue over a 1200 Hz bandwidth from 600-1800 Hz. Displacement fields due to propagating shear waves were measured during continuous, harmonic excitation of the skull. This protocol enabled characterization of the true steady-state patterns of shear wave propagation. Analysis of displacement fields obtained at different frequencies indicates that the viscoelastic properties of mouse brain tissue depend strongly on frequency. The average storage modulus (G') increased from approximately 1.6 to 8 kPa over this range; average loss modulus (G″) increased from approximately 1 to 3 kPa. Both moduli were well approximated by a power-law relationship over this frequency range. MRE may be a valuable addition to studies of disease in murine models, and to pre-clinical evaluations of therapies. Quantitative measurements of the viscoelastic parameters of brain tissue at high frequencies are also valuable for modeling and simulation of traumatic brain injury.
The placenta performs a wide range of physiological functions; insufficiencies in these functions may result in a variety of severe prenatal and postnatal syndromes with long-term negative impacts on human adult health. Recent advances in magnetic resonance imaging (MRI) studies of placental function, in both animal models and humans, have contributed significantly to our understanding of placental structure, blood flow, oxygenation status, and metabolic profile, and have provided important insights into pregnancy complications.
23 November 2004 in Magnetic Resonance in Medicine
Hyperpolarized 3He images of mouse lung are presented. Ventilation images and measurements of 3He apparent diffusion coefficient (ADC) are reported in healthy mice, and preliminary studies of emphysema and lung cancer in mice are described using these techniques. The design and operation of an electronically controlled small‐animal ventilator to deliver the hyperpolarized gas and control animal respiration are described. Images are acquired using an asymmetric gradient echo imaging method to enhance the signal‐to‐noise ratio of the rapidly diffusing 3He. In mice with elastase‐induced emphysema, the whole‐lung average ADC is greater by approximately 25%, a statistically significant difference, compared to healthy animals. By contrast, mice exposed to cigarette smoke for up to 12 months reveal no statistically relevant increases in ADC, although emphysema was not confirmed in these mice. A study of lung cancer (melanoma) in mice is also presented. While tumors are shown to cause substantial ventilation defects in the lung, these defects appear confined to the cancerous regions and do not extend to large‐scale regions of the lung distal to the tumors. Magn Reson Med 52:1310–1317, 2004.