Thermal comfort sensation can be predicted in the most exact way based on Fanger?s predicted mean vote (PMV) model. This evaluation method takes all the six influencing factors into consideration: air temperature and humidity, air velocity, mean radiant temperature of surrounding surfaces, clothing insulation, and occupants? activities. Fanger?s PMV method was developed for temperate climate and European people, with the participation of university students as subjects. Many researchers had investigated its validity in different geographic locations (i. e. climatic conditions, people) and under non-laboratory circumstances. The results were summarised by van Hoof which had been published in the scientific references. The articles gave us the idea to elaborate the former measurement results. During the last decades thermal comfort was evaluated by our research team using subjective scientific questionnaires and applying the objective Fanger?s model in several office buildings in Hungary. The relation between the PMV and actual mean vote values were analysed based on these results. Investigations were carried out under steady-state conditions in winter time. We performed objective thermal comfort evaluations based on instrumental measurements using the PMV theory. Parallel to this we assessed the subjective thermal sensation using scientific questionnaires. The mathematical relationship between the actual mean vote and PMV was defined according to the evaluated thermal environment: AMV = PMV + 0.275, (arg. ?1.7 ? PMV ? +0.5).
This article deals with the degrees of freedom and possible optimums, specifically with the energy optimums of the heat pump heating system. The authors developed an multi objective optimization procedure that allows for the determination of the optimal motor power for the circulation and well pumps in order to achieve the maximum . Upon selecting the type and size of the water-to-water heat pump, based on the heating demand of the buildings, the proper power of the circulation and well pumps must be determined. There are several procedures used for determining the pump’s power. However, none of those methods ensures the optimum power, i.e., the maximum coefficient of performance, of the heating system. In this study, a multi objective analytical-numerical dimensioning procedure was developed for the determination of the optimal mass flow rate of warm and well water. Based on the flow rate values, the optimum power of the circulation and well pumps can be calculated. Due to the wide scope of the topic, the application of the optimization procedure is presented in a case study, but only for determining the optimum power of the circulation pump. The validity of the procedure was confirmed by measurements. The results obtained with the optimization showed that through the energy optimization of the circulation pump power, the of the system increased by 5.34%.
This paper analyzes the energy efficiency of the heat pump and the complete heat pump heating system. Essentially, the maximum of the coefficient of performance of the heat pump and the heat pump heating system are investigated and determined by applying a new analytical optimization procedure. The analyzed physical system consists of the water-to-water heat pump, circulation and well pump. In the analytical optimization procedure the "first derivative equal to zero" mathematical method is applied. The objective function is the coefficient of performance of the heat pump, and the heat pump heating system. By using the analytical optimization procedure and the objective function, as the result, the local and the total energy optimum conditions with respect to the mass flow rate of hot and cold water i. e. the power of circulation or well pump are defined.
1 August 2018 in Facta Universitatis, Series: Mechanical Engineering
Using a dynamical mathematical model, we investigated transient behavior of a water-water heat pump’s evaporator. The model consists of time and space dependent partial differential equations of water, pipe wall and refrigerant. Mathematically the thermal expansion valve (TEV) and compressor are described with lumped parameters and represent the boundary conditions. During the numerical solution of this system of equations the problem emerged of divergence of solutions. It was determined that the cause of the divergence solution was in the location of phase change of the refrigerant. The aim of this paper is, firstly, to display and propose a new approach to the elimination of divergence. In addition, it examines dynamic behavior of the heat pumps’ coaxial evaporator.