Roser Viñals Terrés

Mrs. Roser Viñals Terrés

École Polytechnique Fédérale de Lausanne, Lausanne, Vaud, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
MJMagali Jonnalagedda
Magali Jonnalagedda
PPPatrick Petignat
Patrick Petignat
JTJean-Philippe Thiran
Jean-Philippe Thiran
PVPierre Vassilakos
Pierre Vassilakos
Visual inspection with acetic acid (VIA) is one of the methods recommended by the World Health Organization for cervical cancer screening. VIA is simple and low-cost; it, however, presents high subjectivity. We conducted a systematic literature search in PubMed, Google Scholar and Scopus to identify automated algorithms for classifying images taken during VIA as negative (healthy/benign) or precancerous/cancerous. Of the 2608 studies identified, 11 met the inclusion criteria. The algorithm with the highest accuracy in each study was selected, and some of its key features were analyzed. Data analysis and comparison between the algorithms were conducted, in terms of sensitivity and specificity, ranging from 0.22 to 0.93 and 0.67 to 0.95, respectively. The quality and risk of each study were assessed following the QUADAS-2 guidelines. Artificial intelligence-based cervical cancer screening algorithms have the potential to become a key tool for supporting cervical cancer screening, especially in settings where there is a lack of healthcare infrastructure and trained personnel. The presented studies, however, assess their algorithms using small datasets of highly selected images, not reflecting whole screened populations. Large-scale testing in real conditions is required to assess the feasibility of integrating those algorithms in clinical settings.

18 February 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
JSJ. Sami
J. Sami
SLSophie Lemoupa
Sophie Lemoupa
EJEmilien Jeannot
Emilien Jeannot
BKBruno Kenfack
Bruno Kenfack
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
PPPatrick Petignat
Patrick Petignat
Visual inspection with acetic acid (VIA) is recommended by the World Health Organization for primary cervical cancer screening or triage of human papillomavirus-positive women living in low-resource settings. Nonetheless, traditional VIA with the naked-eye is associated with large variabilities in the detection of pre-cancer and with a lack of quality control. Digital-VIA (D-VIA), using high definition cameras, allows magnification and zooming on transformation zones and suspicious cervical regions, as well as simultaneously compare native and post-VIA images in real-time. We searched MEDLINE and LILACS between January 2015 and November 2021 for relevant studies conducted in low-resource settings using a smartphone device for D-VIA. The aim of this review was to provide an evaluation on available data for smartphone use in low-resource settings in the context of D-VIA-based cervical cancer screenings. The available results to date show that the quality of D-VIA images is satisfactory and enables CIN1/CIN2+ diagnosis, and that a smartphone is a promising tool for cervical cancer screening monitoring and for on- and off-site supervision, and training. The use of artificial intelligence algorithms could soon allow automated and accurate cervical lesion detection.

23 November 2023 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
JTJean-Philippe Thiran
Jean-Philippe Thiran
Ultrafast ultrasound imaging, characterized by high frame rates, generates low-quality images. Convolutional neural networks (CNNs) have demonstrated great potential to enhance image quality without compromising the frame rate. However, CNNs have been mostly trained on simulated or phantom images, leading to suboptimal performance on in vivo images. In this study, we present a method to enhance the quality of single plane wave (PW) acquisitions using a CNN trained on in vivo images. Our contribution is twofold. Firstly, we introduce a training loss function that accounts for the high dynamic range of the radio frequency data and uses the Kullback–Leibler divergence to preserve the probability distributions of the echogenicity values. Secondly, we conduct an extensive performance analysis on a large new in vivo dataset of 20,000 images, comparing the predicted images to the target images resulting from the coherent compounding of 87 PWs. Applying a volunteer-based dataset split, the peak signal-to-noise ratio and structural similarity index measure increase, respectively, from 16.466 ± 0.801 dB and 0.105 ± 0.060, calculated between the single PW and target images, to 20.292 ± 0.307 dB and 0.272 ± 0.040, between predicted and target images. Our results demonstrate significant improvements in image quality, effectively reducing artifacts.

17 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
PVPierre Vassilakos
Pierre Vassilakos
MRMohammad Saeed Rad
Mohammad Saeed Rad
MUManuela Undurraga
Manuela Undurraga
PPPatrick Petignat
Patrick Petignat
JTJean-Philippe Thiran
Jean-Philippe Thiran
Cervical cancer remains a major public health concern in developing countries due to financial and human resource constraints. Visual inspection with acetic acid (VIA) of the cervix was widely promoted and routinely used as a low-cost primary screening test in low- and middle-income countries. It can be performed by a variety of health workers and the result is immediate. VIA provides a transient whitening effect which appears and disappears differently in precancerous and cancerous lesions, as compared to benign conditions. Colposcopes are often used during VIA to magnify the view of the cervix and allow clinicians to visually assess it. However, this assessment is generally subjective and unreliable even for experienced clinicians. Computer-aided techniques may improve the accuracy of VIA diagnosis and be an important determinant in the promotion of cervical cancer screening. This work proposes a smartphone-based solution that automatically detects cervical precancer from the dynamic features extracted from videos taken during VIA. The proposed solution achieves a sensitivity and specificity of 0.9 and 0.87 respectively, and could be a solution for screening in countries that suffer from the lack of expensive tools such as colposcopes and well-trained clinicians.

29 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
OMOlga Muñoz
Olga Muñoz
AAAdrián Agustín
Adrián Agustín
JVjosep vidal
josep vidal
In this paper, we design linear precoders for the downlink of a visible light communication (VLC) system that simultaneously serves multiple users. Instead of using phosphor-coated white light-emitting diodes (PWLEDs), we focus on Red-Green-Blue light-emitting diodes (RGB-LEDs) that allow modulating three separate data streams on the three primary colors of the RGB-LEDs. For this system, we design a zero-forcing (ZF) precoder that maximizes the weighted sum rate for a multilevel pulse amplitude modulation (M-PAM). The precoding design in RGB-based systems presents some challenges due to the system constraints, such as the limited power, the non-negative amplitude constraints per light-emitting diode (LED), and the need to guarantee white light emission while transmitting with RGB-LEDs. For comparison purposes, we also consider the ZF design for a PWLED-based system and evaluate the performance of both a PWLED- and an RGB-based system.

1 December 2017
Verified
Conference Paper
Closed access
Roser Viñals TerrésRoser Viñals Terrés
Roser Viñals Terrés
OMOlga Muñoz
Olga Muñoz
AAAdrian Agustin
Adrian Agustin
JVJosep Vidal
Josep Vidal
This paper develops and evaluates precoding techniques for coordinated joint transmission in visible light communications (VLC). A multi-user multiple-input single-output (MISO) setup is adopted. Transmitters are equipped with light emitting diode (LED) arrays, while receivers incorporate a single photodetector (PD). We design zero forcing (ZF) linear precoders considering, as figure of merit, the weighted sumrate for multilevel pulse amplitude modulation (PAM) and take into account the optical power constraints. We present two approaches. First, we formulate the design as a convex optimization problem and find its exact solution. Second, by considering certain approximations, we find an alternative precoder that despite being suboptimal can be computed in an almost closed-form, achieving a good trade-off between performance and complexity. Finally, we demonstrate that the proposed approaches largely outperform the conventional pseudo-inverse precoding and single-user TDMA approaches.