Norma G. Padilla-Eguiluz

Mrs. Norma G. Padilla-Eguiluz

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2014 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
MOMiguel Ortega-Andreu
Miguel Ortega-Andreu
NPNorma G. Padilla-Eguiluz
Norma G. Padilla-Eguiluz
HPHanna Pérez-Chrzanowska
Hanna Pérez-Chrzanowska
RFReyes Figueredo-Zalve
Reyes Figueredo-Zalve
Background: Abundant literature regarding the use of intravenous tranexamic acid (TXA) in primary total knee replacement is available. Randomized controlled trials have confirmed the efficacy of topical TXA compared with placebo, but the comparison between topical and intravenous TXA is unclear. The present study was designed to verify noninferior efficacy and safety of topical intra-articular TXA compared with intravenous TXA in primary total knee replacement with cemented implants. Methods: A Phase-III, single-center, double-blind, randomized, controlled clinical trial was performed to compare topical intra-articular TXA (3 g of TXA in 100 mL of physiological saline solution) with two intravenous doses of TXA (15 mg/kg in 100 mL of physiological saline solution, one dose before tourniquet release and another three hours after surgery) in a multimodal protocol for blood loss prevention. The primary outcome was the blood transfusion rate, and the secondary outcomes included visible blood loss (as measured in the drain) at twenty-four hours postoperatively and invisible blood loss (as estimated from the Nadler formula) at forty-eight hours postoperatively. The sample size of seventy-eight patients was calculated to give a statistical power of 99% for demonstrating noninferiority. Thirty-nine patients each were allocated to receive topical intra-articular TXA (the experimental group) and intravenous TXA (the control group); there were no significant differences in demographics or preoperative laboratory values between the groups. Noninferiority was estimated by comparing the confidence intervals with a delta of 10%. Student t and Mann-Whitney tests were used to assess the significance of any differences. Results: The transfusion rate was zero in both groups; thus, noninferiority was demonstrated for the primary efficacy end point, suggesting equivalence. Noninferiority was also demonstrated for the secondary efficacy end points. Drain blood loss at twenty-four hours was 315.6 mL (95% confidence interval [CI], 248.5 to 382.7 mL) in the experimental group and 308.1 mL (95% CI, 247.6 to 368.5 mL) in the control group (p = 0.948, Mann-Whitney). Also, estimated blood loss at forty-eight hours was 1259.0 mL (95% CI, 1115.6 to 1402.3 mL) in the experimental group and 1317.9 mL (95% CI, 1175.4 to 1460.4 mL) in the control group (p = 0.837, Mann-Whitney). No significant safety differences were seen between groups. Conclusions: Topical administration of TXA according to the described protocol demonstrated noninferiority compared with intravenous TXA, with no safety concerns. This randomized controlled trial supports the topical intra-articular administration of TXA in primary total knee replacement with cemented implants. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 March 2019 in Biomaterials
Verified
Journal Article
Open access
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
PRPhilippe Rosset
Philippe Rosset
FGFlorian Gebhard
Florian Gebhard
PHPhilippe Hernigou
Philippe Hernigou
Nicola BaldiniNicola Baldini
Nicola Baldini
Pierre LayrollePierre Layrolle
Pierre Layrolle
ORTHO-1 is a European, multicentric, first in human clinical trial to prove safety and feasibility after surgical implantation of commercially available biphasic calcium phosphate bioceramic granules associated during surgery with autologous mesenchymal stromal cells expanded from bone marrow (BM-hMSC) under good manufacturing practices, in patients with long bone pseudarthrosis. Twenty-eight patients with femur, tibia or humerus diaphyseal or metaphyso-diaphyseal non-unions were recruited and surgically treated in France, Germany, Italy and Spain with 100 or 200 million BM-hMSC/mL associated with 5-10 cc of bioceramic granules. Patients were followed up during one year. The investigational advanced therapy medicinal product (ATMP) was expanded under the same protocol in all four countries, and approved by each National Competent Authority. With safety as primary end-point, no severe adverse event was reported as related to the BM-hMSC. With feasibility as secondary end-point, the participating production centres manufactured the BM-hMSC as planned. The ATMP combined to the bioceramic was surgically delivered to the non-unions, and 26/28 treated patients were found radiologically healed at one year (3 out of 4 cortices with bone bridging). Safety and feasibility were clinically proven for surgical implantation of expanded autologous BM-hMSC with bioceramic. EU-FP7-HEALTH-2009, REBORNE Project (GA: 241876).

7 December 2013 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
SMSara Moráis
Sara Moráis
MOMiguel Ortega-Andreu
Miguel Ortega-Andreu
EREmerito Carlos Rodríguez-Merchán
Emerito Carlos Rodríguez-Merchán
NPNorma G. Padilla-Eguiluz
Norma G. Padilla-Eguiluz
HPHanna Pérez-Chrzanowska
Hanna Pérez-Chrzanowska
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena

22 February 2018 in Stem Cells International
Verified
Journal Article
Open access
PDF file
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
NPNorma G. Padilla-Eguiluz
Norma G. Padilla-Eguiluz
CACristina Avendaño-Solá
Cristina Avendaño-Solá
CPConcepción Payares-Herrera
Concepción Payares-Herrera
AVAna Velasco-Iglesias
Ana Velasco-Iglesias
FCFabio Catani
Fabio Catani
ORTHOUNION is a multicentre, open, comparative, three-arm, randomized clinical trial (EudraCT number 2015-000431-32) to compare the efficacy, at one and two years, of autologous human bone marrow-derived expanded mesenchymal stromal cell (hBM-MSC) treatments versus iliac crest autograft (ICA) to enhance bone healing in patients with diaphyseal and/or metaphysodiaphyseal fracture (femur, tibia, and humerus) status of atrophic or oligotrophic nonunion (more than 9 months after the acute fracture, including recalcitrant cases after failed treatments). The primary objective is to determine if the treatment with hBM-MSCs combined with biomaterial is superior to ICA in obtaining bone healing. If confirmed, a secondary objective is set to determine if the dose of 100 × 106 hBM-MSCs is noninferior to that of 200 × 106 hBM-MSCs. The participants (n=108) will be randomly assigned to either the experimental low dose (n=36), the experimental high dose (n=36), or the comparator arm (n=36) using a central randomization service. The trial will be conducted in 20 clinical centres in Spain, France, Germany, and Italy under the same clinical protocol. The confirmation of superiority for the proposed ATMP in nonunions may foster the future of bone regenerative medicine in this indication. On the contrary, absence of superiority may underline its limitations in clinical use.

1 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
NPNorma G. Padilla-Eguiluz
Norma G. Padilla-Eguiluz
PRPhilippe Rosset
Philippe Rosset
Philippe HernigouPhilippe Hernigou
Philippe Hernigou
Nicola BaldiniNicola Baldini
Nicola Baldini
OCon behalf of the REBORNE Consortium
on behalf of the REBORNE Consortium
Background: Osteonecrosis (ON) of the femoral head represents a potentially severe disease of the hip where the lack of bone regeneration may lead to femoral head collapse and secondary osteoarthritis, with serious pain and disability. The aim of this European, multicentric clinical trial was to prove safety and early efficacy to heal early femoral head ON in patients through minimally invasive surgical implantation of autologous mesenchymal stromal cells (MSC) expanded from bone marrow (BM) under good manufacturing practices (GMP). Methods: Twenty-two patients with femoral head ON (up to ARCO 2C) were recruited and surgically treated in France, Germany, Italy and Spain with BM-derived, expanded autologous MSC (total dose 140 million MSC in 7 mL). The investigational advanced therapy medicinal product (ATMP) was expanded from BM under the same protocol in all four countries and approved by each National Competent Authority. Patients were followed during two years for safety, based on adverse events, and for efficacy, based on clinical assessment (pain and hip score) and imaging (X-rays and MRIs). Patients were also reviewed after 5 to 6 years at latest follow-up for final outcome. Results: No severe adverse event was recalled as related to the ATMP. At 12 months, 16/20 per protocol and 16/22 under intention-to-treat (2 drop-out at 3 and 5 months) maintained head sphericity and showed bone regeneration. Of the 4 hips with ON progression, 3 required total hip replacement (THR). At 5 years, one patient (healed at 2 years visit) was not located, and 16/21 showed no progression or THR, 4/21 had received THR (all in the first year) and 1 had progressed one stage without THR. Conclusions: Expanded MSCs implantation was safe. Early efficacy was confirmed in 80% of cases under protocol at 2 years. At 5 years, the overall results were maintained and 19% converted to THR, all in the first year.

1 April 2020 in Injury
Verified
Journal Article
Open access
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
NPNorma G. Padilla-Eguiluz
Norma G. Padilla-Eguiluz
EGEduardo García-Rey
Eduardo García-Rey
PHPablo Hernández-Esteban
Pablo Hernández-Esteban
JCJosé Cordero-Ampuero
José Cordero-Ampuero
JRJuan C. Rubio-Suárez
Juan C. Rubio-Suárez
The available scores to clinically evaluate fracture consolidation encounter difficulties to interpret progression towards consolidation in long-bone non-union, particularly when incorporating biomaterials in the surgical treatment. The aims of this study were to validate the REBORNE bone healing scale in tibia, humerus and femur non-unions treated by a combination of mesenchymal stromal cells (MSCs) and biomaterials, through the interclass correlation (ICC) among raters, and to define reliability and concordance in anteroposterior and lateral radiographs, compared to computed tomography (CT). Twenty-six cases from the EudraCT 2011-005441-13 clinical trial underwent bone healing evaluation, if at least 3 out of 4 cortical views clearly identified. Three senior orthopaedic surgeons evaluated radiographs and CTs at 3 and 6 months FU. All cases included preoperative imaging and radiographs at 12 months. The 4-stage scale score was obtained from each cortical view in orthogonal radiographs or CTs. A score of 0.6875 (11/16) was set as a threshold for bone healing. Statistically, ICC evaluated agreement among raters. Cronbach's alpha coefficient tested reliability. Lin's concordance correlation coefficients (CCC) were estimated between mean CT scores and mean radiographic scores. Bland and Altman graphs provided the limits of agreement between both imaging techniques. Sensitivity and specificity were assessed in radiographs (against CT), and the Area Under the Receiver Operating Characteristics (ROC) Curve was estimated. The probability to predict bone consolidation with REBORNE scores obtained from radiographs was modelled. An ICC of 0.88 and 0.91 (CT and radiographs) confirmed agreement in the REBORNE score for non-union bone healing, with an inter-rater reliability of 0.92 and 0.95. Scores through the radiographic evaluation were found equivalent to the CTs at 6 months FU. A CCC of 0.79 was detected against CT. The radiographic scores in the REBORNE bone healing scale correctly classified bone consolidation in 77%, with an accuracy of 83% based on ROC curves. The REBORNE score measured with CT or radiographic images was reliable among raters at a follow-up time above 6 months for long bone non-union fractures. The REBORNE scale measured with radiographs proved valid to assess consolidation against CT measurements.