In both aquatic and terrestrial environment, selenium contamination may exist at concentrations above the micronutrient limit. Since there is such a narrow bandwidth between which selenium concentration is acceptable, the health of the public may be at risk of selenium toxicity once the concentration increases beyond a threshold. Selenium contamination in an aqueous environment can occur due to anthropogenic activities and/or from natural sources. This study presents a review of the forms of selenium, inorganic and organic selenium contamination, mobilization, analytical methods for various forms of selenium and remediation strategies. The review also provides recent advances in removal methods for selenium from water including bioremediation, precipitation, coagulation, electrocoagulation, adsorption, nano-zerovalent iron, iron co-precipitation and other methods. A review of selenomethionine and selenocysteine removal strategy from industrial wastewaters is presented. Selenium resource recovery from copper ore processing has been discussed. Various analytical methods used for selenium and heavy metal analysis were compared. Importantly, existing knowledge gaps were identified and prospective areas for further research were recommended.
Selenomethionine (SeMet) and selenocysteine (SeCys) are the most common forms of organic selenium, which is often found in the effluent of industrial wastewater. These organic selenium compounds are toxic, bioavailable and most likely to bioaccumulate in aquatic organisms. This study investigated the use of two adsorbent candidates (granular activated carbon (GAC) and nano zerovalent iron (nZVI)) as treatment technologies for SeMet and SeCys removal. Batch experiments were performed and inductively coupled plasma optical emission spectrometer (ICP-OES) was used for sample analysis. Experimental data showed GAC demonstrated a higher affinity towards the removal of SeMet and SeCys compared to nZVI. The removal efficiency of SeCys and SeMet by GAC was 96.1% and 86.7%, respectively. NZVI adsorption capacity for SeCys was 39.4% and SeMet < 1.1%. Irrespective of the adsorbent, SeMet is more refractory to be adsorbed compared to SeCys. Kinetics data of GAC and nZVI agreed well with the pseudo-second-order model (R2 > 0.990). The experimental data of SeCys was characterized by Langmuir model, indicating monolayer adsorption. The adsorption capacity of nZVI for SeCys increased significantly by about 35%, with a decrease in pH from 9.0 to 4.0, indicating that SeCy removal by nZVI is pH dependent. While electrostatic attraction is considered the driving mechanism for nZVI adsorption, GAC uptake capacity is controlled by weak van der Waal forces. The adsorption of binary adsorbates (SeMet and SeCys) exhibited an inhibitory effect due to the competitive interaction between contaminant molecules.
Nanoscale zerovalent iron particles (nZVI) immobilized on coconut shell-based granular activated carbon (GAC) were studied to remove organoselenium from wastewater. A chemical reduction technique that involves the application of sodium borohydride was adopted for the adsorbent preparation. The texture, morphology and chemical composition of the synthesized adsorbents were analyzed with a scanning electron microscope (SEM), nitrogen adsorption–desorption isotherms and X-ray diffraction (XRD). Batch experiment with various pHs and contact times were conducted to evaluate nZVI/GAC adsorption performance. The results showed that nZVI/GAC has a strong affinity to adsorb selenomethionine (SeMet) and selenocysteine (SeCys) from wastewaters. The maximum removal efficiency for the composite (nZVI/GAC) was 99.9% for SeCys and 78.2% for SeMet removal, which was significantly higher than that of nZVI (SeCy, 59.2%; SeMet, 10.8%). The adsorption kinetics were studied by pseudo-first-order (PFO) and pseudo-second-order (PSO) kinetic models. Amongst the two, PSO seemed to have a better fit (SeCy, R2 > 0.998; SeMet, R2 > 0.999). The adsorption process was investigated using Langmuir and Freundlich isotherm models. Electrostatic attraction played a significant role in the removal of organoselenium by nZVI/GAC adsorption. Overall, the results indicated that GAC-supported nZVI can be considered a promising and efficient technology for removing organoselenium from wastewater.