Marco Grisi

Dr. Marco Grisi

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2013 in Nature Communications
Verified
Journal Article
Open access
PDF file
AJAvelino Javer
Avelino Javer
ZLZhicheng Long
Zhicheng Long
ENEileen Nugent
Eileen Nugent
MGMarco Grisi
Marco Grisi
KSKamin Siriwatwetchakul
Kamin Siriwatwetchakul
MLMarco Cosentino Lagomarsino
Marco Cosentino Lagomarsino
In bacteria, chromosomal architecture shows strong spatial and temporal organization, and regulates key cellular functions, such as transcription. Tracking the motion of chromosomal loci at short timescales provides information related to both the physical state of the nucleo–protein complex and its local environment, independent of large-scale motions related to genome segregation. Here we investigate the short-time (0.1–10 s) dynamics of fluorescently labelled chromosomal loci in Escherichia coli at different growth rates. At these timescales, we observe for the first time a dependence of the loci’s apparent diffusion on both their subcellular localization and chromosomal coordinate, and we provide evidence that the properties of the chromosome are similar in the tested growth conditions. Our results indicate that either non-equilibrium fluctuations due to enzyme activity or the organization of the genome as a polymer–protein complex vary as a function of the distance from the origin of replication.

1 April 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MGMarco Grisi
Marco Grisi
GGGabriele Gualco
Gabriele Gualco
GBGiovanni Boero
Giovanni Boero
In this article, we present an integrated broadband complementary metal-oxide semiconductor single-chip transceiver suitable for the realization of multi-nuclear pulsed nuclear magnetic resonance (NMR) probes. The realized single-chip transceiver can be interfaced with on-chip integrated microcoils or external LC resonators operating in the range from 1 MHz to 1 GHz. The dimension of the chip is about 1 mm2. It consists of a radio-frequency (RF) power amplifier, a low-noise RF preamplifier, a frequency mixer, an audio-frequency amplifier, and fully integrated transmit-receive switches. As specific example, we show its use for multi-nuclear NMR spectroscopy. With an integrated coil of about 150 μm external diameter, a 1H spin sensitivity of about 1.5 × 1013 spins/Hz1/2 is achieved at 7 T.

20 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MGMarco Grisi
Marco Grisi
FVFranck Vincent
Franck Vincent
BVBeatrice Volpe
Beatrice Volpe
RGRoberto Guidetti
Roberto Guidetti
NHNicola Harris
Nicola Harris
GBGiovanni Boero
Giovanni Boero
Nuclear magnetic resonance (NMR) spectroscopy enables non-invasive chemical studies of intact living matter. However, the use of NMR at the volume scale typical of microorganisms is hindered by sensitivity limitations, and experiments on single intact organisms have so far been limited to entities having volumes larger than 5 nL. Here we show NMR spectroscopy experiments conducted on single intact ova of 0.1 and 0.5 nL (i.e. 10 to 50 times smaller than previously achieved), thereby reaching the relevant volume scale where life development begins for a broad variety of organisms, humans included. Performing experiments with inductive ultra-compact (1 mm2) single-chip NMR probes, consisting of a low noise transceiver and a multilayer 150 μm planar microcoil, we demonstrate that the achieved limit of detection (about 5 pmol of 1H nuclei) is sufficient to detect endogenous compounds. Our findings suggest that single-chip probes are promising candidates to enable NMR-based study and selection of microscopic entities at biologically relevant volume scales.

15 February 2013 in Physical Review E
Verified
Journal Article
Closed access
TSTomas Svensson
Tomas Svensson
KVKevin Vynck
Kevin Vynck
MGMarco Grisi
Marco Grisi
RSRomolo Savo
Romolo Savo
MBMatteo Burresi
Matteo Burresi
DWDiederik S. Wiersma
Diederik S. Wiersma
We present a probabilistic theory of random walks in turbid media with nonscattering regions. It is shown that important characteristics such as diffusion constants, average step lengths, crossing statistics, and void spacings can be analytically predicted. The theory is validated using Monte Carlo simulations of light transport in heterogeneous systems in the form of random sphere packings and good agreement is found. The role of step correlations is discussed and differences between unbounded and bounded systems are investigated. Our results are relevant to the optics of heterogeneous systems in general and represent an important step forward in the understanding of media with strong (fractal) heterogeneity in particular. DOI: http://dx.doi.org/10.1103/PhysRevE.87.022120 ©2013 American Physical Society

9 May 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EME Montinaro
E Montinaro
MGMarco Grisi
Marco Grisi
MLM C Letizia
M C Letizia
LPL Pethö
L Pethö
MGM A M Gijs
M A M Gijs
GBG Boero
G Boero
Nuclear magnetic resonance (NMR) experiments on subnanoliter (sub-nL) volumes are hindered by the limited sensitivity of the detector and the difficulties in positioning and holding such small samples in proximity of the detector. In this work, we report on NMR experiments on liquid and biological entities immersed in liquids having volumes down to 100 pL. These measurements are enabled by the fabrication of high spatial resolution 3D printed microfluidic structures, specifically conceived to guide and confine sub-nL samples in the sub-nL most sensitive volume of a single-chip integrated NMR probe. The microfluidic structures are fabricated using a two-photon polymerization 3D printing technique having a resolution better than 1 μm3. The high spatial resolution 3D printing approach adopted here allows to rapidly fabricate complex microfluidic structures tailored to position, hold, and feed biological samples, with a design that maximizes the NMR signals amplitude and minimizes the static magnetic field inhomogeneities. The layer separating the sample from the microcoil, crucial to exploit the volume of maximum sensitivity of the detector, has a thickness of 10 μm. To demonstrate the potential of this approach, we report NMR experiments on sub-nL intact biological entities in liquid media, specifically ova of the tardigrade Richtersius coronifer and sections of Caenorhabditis elegans nematodes. We show a sensitivity of 2.5x1013 spins/Hz1/2 on 1H nuclei at 7 T, sufficient to detect 6 pmol of 1H nuclei of endogenous compounds in active volumes down to 100 pL and in a measurement time of 3 hours. Spectral resolutions of 0.01 ppm in liquid samples and of 0.1 ppm in the investigated biological entities are also demonstrated. The obtained results may indicate a route for NMR studies at the single unit level of important biological entities having sub-nL volumes, such as living microscopic organisms and eggs of several mammalians, humans included.

1 January 2016 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
FYFiliz Yesilkoy
Filiz Yesilkoy
RUR. Ueno
R. Ueno
BDB. X. E. Desbiolles
B. X. E. Desbiolles
MGMarco Grisi
Marco Grisi
YSY. Sakai
Y. Sakai
JBJ. Brugger
J. Brugger
The isolation of single biological cells and their further cultivation in dedicated arrayed chambers are key to the collection of statistically reliable temporal data in cell-based biological experiments. In this work, we present a hydrodynamic single cell trapping and culturing platform that facilitates cell observation and experimentation using standard bio-lab equipment. The proposed design leverages the stochastic position of the cells as they flow into the structured microfluidic channels, where hundreds of single cells are then arrayed in nanoliter chambers for simultaneous cell specific data collection. Numerical simulation tools are used to devise and implement a hydrodynamic cell trapping mechanism that is minimally detrimental to the cell cycle and retains high overall trapping efficiency (∼70%) with the capability of reaching high fill factors (>90%) in short loading times (1–4 min) in a 400-trap device. A Monte Carlo model is developed using the design parameters to estimate the system trapping efficiencies, which show strong agreement with the experimentally acquired data. As proof of concept, arrayed mammalian tissue cells (MIA PaCa-2) are cultured in the microfluidic chambers for two days without viability problems.