Tomohiro Ishikawa

Mr. Tomohiro Ishikawa

Nagoya University
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in Galaxies
Verified
Journal Article
Open access
PDF file
TITomohiro Ishikawa
Tomohiro Ishikawa
SIShoki Iwaguchi
Shoki Iwaguchi
YMYuta Michimura
Yuta Michimura
MAMasaki Ando
Masaki Ando
RYRika Yamada
Rika Yamada
SKSeiji Kawamura
Seiji Kawamura
The DECi-hertz Interferometer Gravitational-wave Observatory (DECIGO) is the future Japanese, outer space gravitational wave detector. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us toward further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR) of the primordial GWs to quantum noise, including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry–Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimensions and implementing other noise sources.

1 January 1997 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
Verified
Journal Article
Closed access
TKT. Kitano
T. Kitano
SIS. Izumi
S. Izumi
HMH. Minami
H. Minami
TITomohiro Ishikawa
Tomohiro Ishikawa
KSKanta Sato
Kanta Sato
MOM. Otsubo
M. Otsubo
We have developed a novel selective citric acid-based etchant used for GaAs over AlGaAs, which consists of citric acid, NH4OH, and H2O2. The etching rate ratio of GaAs to Al0.15Ga0.85As was as high as 80 by optimizing the pH and citric acid/H2O2 ratio. The etch stop mechanism was investigated using x-ray photoelectron spectroscopy. The etching is stopped at the AlGaAs surface due to Al2O3 formation, whose density is higher than that on a nonselectively etched surface. This selective citric acid-based etchant was applied to the fabrication of GaAs/AlGaAs heterostructure field effect transistors (HFETs). The threshold voltages of the HFETs exhibit excellent uniformity (the standard deviation of 32 mV across the 3 in. wafer), demonstrating the applicability of this selective etchant to the gate recess process.

26 January 2021 in Galaxies
Verified
Journal Article
Open access
PDF file
SIShoki Iwaguchi
Shoki Iwaguchi
TITomohiro Ishikawa
Tomohiro Ishikawa
MAMasaki Ando
Masaki Ando
YMYuta Michimura
Yuta Michimura
KKKentaro Komori
Kentaro Komori
SKSeiji Kawamura
Seiji Kawamura
The DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is designed to detect gravitational waves at frequencies between 0.1 and 10 Hz. In this frequency band, one of the most important science targets is the detection of primordial gravitational waves. DECIGO plans to use a space interferometer with optical cavities to increase its sensitivity. For evaluating its sensitivity, diffraction of the laser light has to be adequately considered. There are two kinds of diffraction loss: leakage loss outside the mirror and higher-order mode loss. These effects are treated differently inside and outside of the Fabry-Perot (FP) cavity. We estimated them under the conditions that the FP cavity has a relatively high finesse and the higher-order modes do not resonate. As a result, we found that the effects can be represented as a reduction of the effective finesse of the cavity with regard to quantum noise. This result is useful for optimization of the design of DECIGO. This method is also applicable to any FP cavities with a relatively small beam cut and the finesse sufficiently higher than 1.

1 February 2022 in Galaxies
Verified
Journal Article
Open access
PDF file
YKYuki Kawasaki
Yuki Kawasaki
RSRyuma Shimizu
Ryuma Shimizu
TITomohiro Ishikawa
Tomohiro Ishikawa
KNKoji Nagano
Koji Nagano
SIShoki Iwaguchi
Shoki Iwaguchi
SKSeiji Kawamura
Seiji Kawamura
The DECi-hertz Interferometer Gravitational-Wave Observatory (DECIGO) is a space gravitational wave (GW) detector. DECIGO was originally designed to be sensitive enough to observe primordial GW background (PGW). However, due to the lowered upper limit of the PGW by the Planck observation, further improvement of the target sensitivity of DECIGO is required. In the previous studies, DECIGO’s parameters were optimized to maximize the signal-to-noise ratio (SNR) of the PGW to quantum noise including the effect of diffraction loss. To simulate the SNR more realistically, we optimize DECIGO’s parameters considering the GWs from double white dwarfs (DWDs) and the thermal noise of test masses. We consider two cases of the cutoff frequency of GWs from DWDs. In addition, we consider two kinds of thermal noise: thermal noise in a residual gas and internal thermal noise. To investigate how the mirror geometry affects the sensitivity, we calculate it by changing the mirror mass, keeping the mirror thickness, and vice versa. As a result, we obtained the optimums for the parameters that maximize the SNR that depends on the mirror radius. This result shows that a thick mirror with a large radius gives a good SNR and enables us to optimize the design of DECIGO based on the feasibility study of the mirror size in the future.

8 June 2022 in Physical Review D
Verified
Journal Article
Closed access
PDF file
ANAtsushi Nishizawa
Atsushi Nishizawa
SIShoki Iwaguchi
Shoki Iwaguchi
YCYanbei Chen
Yanbei Chen
TMTaigen Morimoto
Taigen Morimoto
TITomohiro Ishikawa
Tomohiro Ishikawa
SKSeiji Kawamura
Seiji Kawamura
An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, ∼105  Hz even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to ∼10−1  Hz. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.

19 January 2023 in Physical Review D
Verified
Journal Article
Closed access
PDF file
TITomohiro Ishikawa
Tomohiro Ishikawa
YKYuki Kawasaki
Yuki Kawasaki
KTKenji Tsuji
Kenji Tsuji
RYRika Yamada
Rika Yamada
IWIzumi Watanabe
Izumi Watanabe
SKSeiji Kawamura
Seiji Kawamura
Decihertz Interferometer Gravitational Wave Observatory (DECIGO) is a future mission for a space-borne laser interferometer. DECIGO has 1000-km-long arm cavities mainly to detect the primordial gravitational waves (PGWs) at lower frequencies around 0.1 Hz. Observations in the electromagnetic spectrum have lowered the bounds on the upper limit of PGWs energy density (Ωgw∼10−15→10−16). As a result, DECIGO’s target sensitivity, which is mainly limited by quantum noise, needs further improvement. To maximize the feasibility of detection while constrained by DECIGO’s large diffraction loss, a quantum locking technique with an optical spring was theoretically proposed to improve the signal-to-noise ratio of the PGWs. In this paper, we experimentally verify one key element used in the theory: sensitivity optimization by completing the square of multiple detector outputs. This experiment is operated on a simplified tabletop optical setup with classical noise simulating quantum noise. We succeed in getting the best of the sensitivities with two different laser powers by the square completion method.