Yuki Kawasaki

Mr. Yuki Kawasaki

Department of Physics
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Galaxies
Verified
Journal Article
Open access
PDF file
YKYuki Kawasaki
Yuki Kawasaki
RSRyuma Shimizu
Ryuma Shimizu
TITomohiro Ishikawa
Tomohiro Ishikawa
KNKoji Nagano
Koji Nagano
SIShoki Iwaguchi
Shoki Iwaguchi
SKSeiji Kawamura
Seiji Kawamura
The DECi-hertz Interferometer Gravitational-Wave Observatory (DECIGO) is a space gravitational wave (GW) detector. DECIGO was originally designed to be sensitive enough to observe primordial GW background (PGW). However, due to the lowered upper limit of the PGW by the Planck observation, further improvement of the target sensitivity of DECIGO is required. In the previous studies, DECIGO’s parameters were optimized to maximize the signal-to-noise ratio (SNR) of the PGW to quantum noise including the effect of diffraction loss. To simulate the SNR more realistically, we optimize DECIGO’s parameters considering the GWs from double white dwarfs (DWDs) and the thermal noise of test masses. We consider two cases of the cutoff frequency of GWs from DWDs. In addition, we consider two kinds of thermal noise: thermal noise in a residual gas and internal thermal noise. To investigate how the mirror geometry affects the sensitivity, we calculate it by changing the mirror mass, keeping the mirror thickness, and vice versa. As a result, we obtained the optimums for the parameters that maximize the SNR that depends on the mirror radius. This result shows that a thick mirror with a large radius gives a good SNR and enables us to optimize the design of DECIGO based on the feasibility study of the mirror size in the future.

9 November 2023 in Galaxies
Verified
Journal Article
Open access
PDF file
KTKenji Tsuji
Kenji Tsuji
TITomohiro Ishikawa
Tomohiro Ishikawa
KKKentaro Komori
Kentaro Komori
KNKoji Nagano
Koji Nagano
YEYutaro Enomoto
Yutaro Enomoto
SKSeiji Kawamura
Seiji Kawamura
Quantum locking using optical spring and homodyne detection has been devised to reduce the quantum noise that limits the sensitivity of the DECIGO, a space-based gravitational-wave antenna in the frequency band around 0.1 Hz for the detection of primordial gravitational waves. The reduction in the upper limit of energy density ΩGW from 2×10−15 to 1×10−16, as inferred from recent observations, necessitates improved sensitivity in the DECIGO to meet its primary science goals. To accurately evaluate the effectiveness of this method, this paper considers a detection mechanism that takes into account the influence of vacuum fluctuations on homodyne detection. In addition, an advanced signal processing method is devised to efficiently utilize signals from each photodetector, and design parameters for this configuration are optimized for the quantum noise. Our results show that this method is effective in reducing quantum noise, despite the detrimental impact of vacuum fluctuations on its sensitivity.

15 March 2024 in Galaxies
Verified
Journal Article
Open access
PDF file
KTKenji Tsuji
Kenji Tsuji
TITomohiro Ishikawa
Tomohiro Ishikawa
KUKurumi Umemura
Kurumi Umemura
YKYuki Kawasaki
Yuki Kawasaki
SIShoki Iwaguchi
Shoki Iwaguchi
SKSeiji Kawamura
Seiji Kawamura
DECIGO is a future Japanese project for the detection of gravitational waves in space. To conduct various scientific missions, including the verification of cosmic inflation through the detection of primordial gravitational waves as the main objective, DECIGO is designed to have high sensitivity in the frequency band from 0.1 to 10 Hz, with arms of length 1000 km. Furthermore, the use of the Fabry-Perotcavity in these arms has been established for the DECIGO project. In this paper, we scrutinize the significance of the Fabry-Perot cavity for promoting this project, with a focus on the possibility of observing gravitational waves from cosmic inflation and binary compact star systems as indicators. The results show that using the Fabry-Perot cavity is extremely beneficial for detecting them, and it is anticipated to enable the opening of a new window in gravitational wave astronomy.

7 May 2024 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
YKYuki Kawasaki
Yuki Kawasaki
SIShoki Iwaguchi
Shoki Iwaguchi
TITomohiro Ishikawa
Tomohiro Ishikawa
ANAtsushi Nishizawa
Atsushi Nishizawa
MKMasaaki Kitaguchi
Masaaki Kitaguchi
SKSeiji Kawamura
Seiji Kawamura
The detection of low-frequency gravitational waves on Earth requires the reduction of displacement noise, which dominates the low-frequency band. One method to cancel test mass displacement noise is a neutron displacement-noise-free interferometer (DFI). This paper proposes a new neutron DFI configuration, a Sagnac-type neutron DFI, which uses a Sagnac interferometer in place of the Mach–Zehnder interferometer. We demonstrate that a sensitivity of the Sagnac-type neutron DFI is higher than that of a conventional neutron DFI with the same interferometer scale. This configuration is particularly significant for neutron DFIs with limited space for construction and limited flux from available neutron sources.

10 October 2024 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
TITomohiro Ishikawa
Tomohiro Ishikawa
YKYuki Kawasaki
Yuki Kawasaki
KTKenji Tsuji
Kenji Tsuji
RSR Shimizu
R Shimizu
KUK Umemura
K Umemura
SKS Kawamura
S Kawamura
A series of quantum locking theories have been proposed to enhance the quantum-noise-limited target sensitivity of the DECi-hertz Interferometer Gravitational wave Observatory. The quantum locking that uses a square completion optimizes the sensitivity across all frequencies. However, a substantial amount of data-series must be post-processed since the square completion is a form of signal processing technique. This paper approaches the optimal sensitivity across all frequencies from an alternative perspective: by optimizing the frequency dependence of a servo gain in a feedback loop. The optimal servo gain is formulated by comparing the alternative method with the square completion method for the same optical setup. This will be shown in general noise issues extending the framework of the quantum locking. We find that the optimal servo gain forms a non-feasible filter but has certain characteristics. We also find that the noise of the measurement signal deteriorates proportionally to the noise measured in the feedback loop when the servo gain is slightly imperfect.