Yongcai Li

Dr. Yongcai Li

None affiliation needed to be shown

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Liu TianLiu Tian
Liu Tian
YLYongcai Li
Yongcai Li
Jun LuJun Lu
Jun Lu
JWJue Wang
Jue Wang
High population density, dense high-rise buildings, and impervious pavements increase the vulnerability of cities, which aggravate the urban climate environment characterized by the urban heat island (UHI) effect. Cities in China provide unique information on the UHI phenomenon because they have experienced rapid urbanization and dramatic economic development, which have had a great influence on the climate in recent decades. This paper provides a review of recent research on the methods and impacts of UHI on building energy consumption, and the practical techniques that can be used to mitigate the adverse effects of UHI in China. The impact of UHI on building energy consumption depends largely on the local microclimate, the urban area features where the building is located, and the type and characteristics of the building. In the urban areas dominated by air conditioning, UHI could result in an approximately 10–16% increase in cooling energy consumption. Besides, the potential negative effects of UHI can be prevented from China in many ways, such as urban greening, cool material, water bodies, urban ventilation, etc. These strategies could have a substantial impact on the overall urban thermal environment if they can be used in the project design stage of urban planning and implemented on a large scale. Therefore, this study is useful to deepen the understanding of the physical mechanisms of UHI and provide practical approaches to fight the UHI for the urban planners, public health officials, and city decision-makers in China.

14 October 2023 in Sustainable Cities and Society
Verified
Journal Article
Closed access
XSXuhui Shi
Xuhui Shi
YLYongcai Li
Yongcai Li
TLTianhe Long
Tianhe Long
NZNingjing Zhao
Ningjing Zhao
SLShuli Liu
Shuli Liu
TLTao Li
Tao Li

13 March 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Liyue ZengLiyue Zeng
Liyue Zeng
Xuelin ZhangXuelin Zhang
Xuelin Zhang
Jun LuJun Lu
Jun Lu
YLYongcai Li
Yongcai Li
Jian HangJian Hang
Jian Hang
HLHong Ling
Hong Ling
Numerical simulation is vital for evaluating urban ventilation. However, accurate urban-scale ventilation modeling requires extensive building surface simulation for computational demand. The distributed drag force approach simplifies the urban canopy by modeling buildings as a porous volume that accounts for momentum and turbulence. This method is a practical solution for simulating urban airflow. The drag force coefficient (Cd) is a crucial aerodynamic parameter in this approach. This study examines how Cd varies with urban design parameters such as plan area density (λp), average building height (H), frontal area density (λf), floor aspect ratio (AR), and sky view factor (SVF). Employing extensive numerical simulations conducted under neutral atmospheric conditions, we explore ranges of λp = 0.04–0.07 and λf = 0.1–1.2. The numerical model has been validated against existing wind tunnel data. The results show that Cd is insensitive to the model scale and background wind speed. We discover a nonlinear relationship between Cd and the parameters λp, λf, and SVF. For urban layouts with cubic-shaped buildings, Cd peaks at different λp within the range of 0.2~0.8. When λp and H are constant, Cd has a linear relationship with AR and λf. It is recommended to use λp, SVF, and AR as predictors for Cd across various urban configurations.

1 January 2017 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
JLJun Lu
Jun Lu
XGXiaolong Gao
Xiaolong Gao
QLQianru Li
Qianru Li
YLYongcai Li
Yongcai Li
Thermal storage capacity and airflow rate of a solar chimney combined with different PCMs are numerically studied during nighttime. PCMs with phase change temperatures of 38°C, 44°C, 50°C, and 63°C are selected in this numerical study. Results show that the maximum average ventilation rate of 610 kg/m2 and maximum thermal storage of 4750 kJ/m2 are achieved at the phase change temperature of 38°C. However, for phase change temperature of 63°C, night ventilation does not occur under the identical conditions. The findings reveal that a lower phase change temperature can increase the chargeability (and therefore the dischargeability) of a solar chimney, since a higher phase change temperature demands higher solar radiation intensity and longer charging time for a solar chimney. For PCM with a phase change temperature of 44°C, most of the heat stored in PCM is lost to ambient through glass cover by radiation and only a small portion is used for heating the air within air channel.

4 October 2024 in Renewable Energy
Verified
Journal Article
Closed access
JWJiachen Wang
Jiachen Wang
JGJinchi Guo
Jinchi Guo
CLCui Liu
Cui Liu
YLYongcai Li
Yongcai Li
CLChunhua Li
Chunhua Li

31 August 2022
Verified
Conference Paper
Open access
PDF file
YBYufu Bai
Yufu Bai
NZNingjing Zhao
Ningjing Zhao
TLTianhe Long
Tianhe Long
YLYongcai Li
Yongcai Li
Buoyancy-driven natural ventilation has the potential to improve the indoor thermal environment without any energy consumption. In this study, the applicability of the dimensionless area design method was studied, and the airflow rate and excess temperature deviation of rooms on different floors were verified. The results demonstrate that the airflow rates on the first, second and third floors are 887.68, 861.84 and 820.93 m3/h, respectively, and the corresponding airflow rates per capita are 88.77, 86.18 and 82.09 m3/h, respectively. In addition, the average indoor temperatures on the first, second and third floors are 298.78, 299.05 and 299.58 K, respectively, with corresponding excess temperatures of 5.72, 5.99 and 6.52 K. The deviation of airflow rate in the room is within the range of 0.59%-4.2%, indicating that the dimensionless area design method is suitable for designing naturally ventilated buildings.