Oxidative stress reflects a disturbance in the balance between the production and accumulation of reactive oxygen species (ROS). ROS are scavenged by the antioxidant system, but when in excess concentration, they can oxidize proteins, lipids, and DNA. DNA damage is usually repaired, and the oxidized products are excreted in urine. 8-hydroxy-2-deoxyguanosine is considered a biomarker for oxidative damage of DNA. It is needed to define background ranges for 8-OHdG, to use it as a measure of oxidative stress overproduction. We established a standardized protocol for a systematic review and meta-analysis to assess background ranges for urinary 8-OHdG concentrations in healthy populations. We computed geometric mean (GM) and geometric standard deviations (GSD) as the basis for the meta-analysis. We retrieved an initial 1246 articles, included 84 articles, and identified 128 study subgroups. We stratified the subgroups by body mass index, gender, and smoking status reported. The pooled GM value for urinary 8-OHdG concentrations in healthy adults with a mean body mass index (BMI) ≤ 25 measured using chemical methods was 3.9 ng/mg creatinine (interquartile range (IQR): 3 to 5.5 ng/mg creatinine). A significant positive association was observed between smoking and urinary 8-OHdG concentrations when measured by chemical analysis. No gender effect was observed.
Oxidative stress has been associated with various inflammation-related human diseases. It is defined as an imbalance between the production and elimination of reactive oxygen species (ROS). ROS can oxidize proteins, lipids, and DNA, and some of these oxidized products are excreted in urine, such as malondialdehyde (MDA), which is considered a biomarker for oxidative damage of lipids. To interpret changes of this biomarker as a measure of oxidative species overproduction in humans, a background range for urinary MDA concentration in the general population is needed. We sought to establish urinary MDA concentration ranges for healthy adult populations based on reported values in the available scientific literature. We conducted a systematic review and meta-analysis using the standardized protocol registered in PROSPERO (CRD42020146623). EMBASE, PubMed, Web of Science, and Cochrane library databases were searched from journal inception up to October 2020. We included 35 studies (divided into 47 subgroups for the quantitative analysis). Only studies that measured creatinine-corrected urinary MDA with high-performance liquid chromatography (HPLC) with mass spectrometry (MS), fluorescence detection, or UV photometry were included. The geometric mean (GM) of urinary MDA concentration was 0.10 mg/g creatinine and 95% percentile confidence interval (CI) 0.07–0.12. Age, geographical location but not sex, and smoking status had a significant effect on urinary MDA concentrations. There was a significant increasing trend of urinary MDA concentrations with age. These urinary MDA values should be considered preliminary, as they are based on mostly moderate to some low-quality evidence studies. Although urinary MDA can reliably reflect excessive oxidative stress in a population, the influence of physiological parameters that affect its meaning needs to be addressed as well as harmonizing the chemical analytical methods.
Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation.
The current evidence on nanomaterial toxicity is mostly derived from experimental studies making it challenging to translate it into human health risks. We established an international cohort (N = 141 workers) within the EU-LIFE project "NanoExplore" to address possible health effects from occupational exposures to nanomaterials. We used a handheld direct-reading optical particle counter to measure airborne nanoparticle number concentrations (PNC) and lung-deposited surface areas (LDSAs). Airborne particles were characterized by TEM and SEM-EDAX. We assessed oxidative/nitrosative stress with a panel of biomarkers in exhaled breath condensate (EBC) (8-isoprostane, malondialdehyde, nitrotyrosine), inflammation (high-sensitivity C reactive protein (hs-CRP), IL-1β, TNF-α, IL-10) and KL-6 (considered as biomarker of interstitial lung fibrosis) and urine (total antioxidant power (TAP), 8-isoprostane, and malondialdehyde). Exhaled breath sampled in gas-sampling bags were assessed for oxidative potential. These biomarkers were quantified pre-shift at the beginning of the workweek and post-shift the 4th day. Relationships between airborne nanoparticle concentration and biomarkers were assessed by multiple linear regression with log-transformed exposure and biomarker concentrations adjusted for potential confounders. We found a positive dose-response relationship for three inflammation biomarkers (IL-10, IL-1β and TNF-α) in EBC with both PNC and LDSA. A negative dose-response relationship was observed between PNC and TAP. This study suggests that occupational exposures to nanoparticles can affect the oxidative balance and the innate immunity in occupationally exposed workers. However, owing to the intrinsic variability of biomarkers, the observed changes along with their health significance should be assessed in a long-term perspective study.
Many pathological conditions and certain airway exposures are associated with oxidative stress (OS). Malondialdehyde (MDA) is an end-product of the oxidation of lipids in our cells and is present in all biological matrices including exhaled breath condensate (EBC). To use MDA as a biomarker of OS in EBC, a reference interval should be defined. Thus, we sought to summarize reference values reported in healthy adult populations by performing a systematic review and meta-analysis using a standardized protocol registered in PROSPERO (CRD42020146623). Articles were retrieved from four major databases and 25 studies with 28 subgroups were included. Defining the distribution of MDA measured in reference populations with a detection combined with a separation technique still represents a challenge due to the low number of studies available, different analytical methods used, and questionable methodological qualities of many studies. The most salient methodological drawbacks have been in data collection and reporting of methods and study results by the researchers. The lack of compliance with the recommendations of the European Respiratory Society and American Thoracic Society was the major limitation in the current research involving EBC. Consequently, we were unable to establish a reference interval for MDA in EBC.