Gérard Poisson

Prof. Gérard Poisson

orcid
Prof. emeritus

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2007 in American Journal of Roentgenology
Verified
Journal Article
Closed access
PAPhilippe Arbeille
Philippe Arbeille
ACArnaud Capri
Arnaud Capri
JAJean Ayoub
Jean Ayoub
VKVeronique Kieffer
Veronique Kieffer
MGMonica Georgescu
Monica Georgescu
GPGérard Poisson
Gérard Poisson
OBJECTIVE. The purpose of this study was to design and validate a method of performing sonography between an expert center and an isolated site. A sonography probe is held on the patient by a robotic arm and remotely controlled from the expert's center. The robotic arm reproduces all the movements of the expert's dummy probe on the patient probe. The system was tested on 87 patients at our hospital.CONCLUSION. Robotic telesonography can be used for reliable diagnosis without moving the patient. No false diagnoses were made in this study. A bandwidth of 250 Kbps via integrated services digital network or satellite is required for reliable diagnosis. Such a system can provide diagnostic information that is currently unavailable in isolated or inaccessible areas and on rescue vehicles.

30 October 2018 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
Hang SuHang Su
Hang Su
Juan SandovalJuan Sandoval
Juan Sandoval
PVPierre Vieyres
Pierre Vieyres
GPGérard Poisson
Gérard Poisson
GFGiancarlo Ferrigno
Giancarlo Ferrigno
EMElena De Momi
Elena De Momi

1 July 2003 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
PAPhilippe Arbeille
Philippe Arbeille
GPGérard Poisson
Gérard Poisson
PVPierre Vieyres
Pierre Vieyres
JAJean Ayoub
Jean Ayoub
MPMaryannick Porcher
Maryannick Porcher
JBJean Louis Boulay
Jean Louis Boulay

1 August 2018 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
Juan SandovalJuan Sandoval
Juan Sandoval
Hang SuHang Su
Hang Su
PVP. Vieyres
P. Vieyres
GPGérard Poisson
Gérard Poisson
GFG. Ferrigno
G. Ferrigno
EMElena De Momi
Elena De Momi

1 February 2003 in Industrial Robot: the international journal of robotics research and application
Verified
Journal Article
Closed access
PDF file
PVPierre Vieyres
Pierre Vieyres
GPGérard Poisson
Gérard Poisson
FCFabien Courrèges
Fabien Courrèges
OMOlivier Mérigeaux
Olivier Mérigeaux
PAPhilippe Arbeille
Philippe Arbeille
Ultrasound examinations represent one of the major diagnostic modalities of future healthcare. They are currently used to support medical space research but require a high skilled operator for both probe positioning on the patient's skin and image interpretation. TERESA is a tele‐echography project that proposes a solution to bring astronauts and remotely located patients on ground quality ultrasound examinations despite the lack of a specialist at the location of the wanted medical act.

1 September 2017
Verified
Conference Paper
Closed access
Juan SandovalJuan Sandoval
Juan Sandoval
GPGérard Poisson
Gérard Poisson
PVPierre Vieyres
Pierre Vieyres
In this paper, we provide a new generalized kinematic formulation of the Remote Center of Motion (RCM) constraint for serial robotic arms to be useful for implementation in torque-controlled robots. A minimally invasive surgery assisted by a serial robot could be used for inserting a surgical tool through a desired insertion position, i.e. trocar position. The restricted movement caused by the trocar, i.e. the RCM constraint, must be guaranteed by the robotic system in order to avoid injury to the patient. The generalized formulation, presented in this paper, associates the task-space with the RCM constraint coordinates, which are described by the minimum distance between the surgical tool and the trocar position. In order to simultaneously achieve the surgical tool-tip trajectory and the RCM constraint, two control methods are proposed and compared, one using a projection in the null-space, the other by combining both tasks using a task-space augmentation method. Moreover, when additional lower priority tasks have to be implemented in the null-space of the two higher priority tasks, the kinematic formulation simplifies the calculation of the null-space projectors. Furthermore, unlike the previous studies, the formulation represented can be applied not only in a kinematic control but also in a dynamic control approach. Simulations were conducted to validate effectiveness of the proposed formulation, using a planar 4-DOF system as well as the dynamic model of a Kuka LBR 7 iiwa R800 robot arm.