Here we provide raw and processed data and methods for the estimation of catalase activities. The method for presenting a simple and accurate colorimetric assay for catalase activities is described. This method is based on the reaction of undecomposed hydrogen peroxide with ammonium molybdate to produce a yellowish color, which has a maximum absorbance at 374 nm. The method is characterized by adding a correction factor to exclude the interference that arises from the presence of amino acids and proteins in serum. The assay acts to keep out the interferences that arose from measurement of absorbance at unsuitable wavelengths.
The details of a precise, accurate, and sensitive spectrophotometric method for measuring catalase activity are presented here. The assay was established for biological samples and depends on the rapid formation of a stable and colored carbonato-cobaltate (III) complex. Samples exhibiting catalase activity are incubated with hydrogen peroxide solution for 2 min prior to rapid mixing of the incubation enzymatic reaction mixture with cobalt-bicarbonate reagent, which assesses non-reacting hydrogen peroxide. Catalase activity is always directly proportional to the rate of dissociation of hydrogen peroxide. Hydrogen peroxide acts to oxidize cobalt (II) to cobalt (III) in the presence of bicarbonate ions; this process ends with the production of a carbonato-cobaltate (III) complex ([Co (CO3)3]Co). The formed end product has two maximum absorbance peaks: 440 nm and 640 nm. The 440-nm peak has been utilized for assessing catalase activity. The catalase activity results of the current method for erythrocyte lysate homogenates were computationally identical to those of the dichromate method (r = 0.9950). The coefficient of variation was calculated to determine the imprecision of the current assay. The within-run and between-run results were 2.96 and 3.83%, respectively. This method is appropriate for analyzing bacteria, red blood cells and liver and kidney tissue homogenates.
Low concentrations of nitric oxide (NO) are necessary for the biology and physiology of spermatozoa, but high levels of NO are toxic and have negative effects on sperm functions. Although several studies have considered the relationship between infertility and semen NO concentrations, no study on the effects of asthenospermia treatments such as oral zinc supplementation on concentrations of NO, which are important in fertility, has been reported. Studies have shown that oral zinc supplementation develops sperm count, motility and the physical characteristics of sperm in animals and in some groups of infertile men. The present study was conducted to study the effect of zinc supplementation on the quantitative and qualitative characteristics of semen, along with enzymes of the NO pathway in the seminal plasma of asthenospermic patients.
Catalase (CAT) is an important enzyme that protects biomolecules against oxidative damage by breaking down hydrogen peroxide (H2O2) into water and oxygen. CAT is present in all aerobic microbes, animals, and plants. It is, however, absent from normal human urine but can be detected in pathological urine. CAT testing can thus help to detect such urine. This study presents a novel spectrophotometric method for determining CAT activity characterized by its simplicity, sensitivity, specificity, and rapidity. The method involves incubating enzyme-containing samples with a carefully chosen concentration of H2O2 for a specified incubation period. Subsequently, a solution containing ferrous ammonium sulfate (FAS) and sulfosalicylic acid (SSA) is added to terminate the enzyme activity. A distinctive maroon-colored ferrisulfosalicylate complex is formed. The formation of this complex is a direct result of the reaction between FAS and any residual peroxide present. This leads to the generation of ferric ions when coordinated with SSA. The complex has a maximum absorbance of 490 nm. This advanced method eliminates the need for concentrated acids to stop CAT activity, making it safer and easier to handle. A comparative analysis against the standard ferrithiocyanate method showed a correlation coefficient of 0.99, demonstrating the new method’s comparable effectiveness and reliability. In conclusion, a simple and reliable protocol for assessing CAT activity, which utilizes a cuvette or microplate, has been demonstrated in this study. This interference-free protocol can easily be used in research and clinical analysis with considerable accuracy and precision.
12 January 2016 in Indian Journal of Science and Technology