Given the abundance of kikuyu biomass resulting from the pruning of green areas, the aim of this study was to evaluate its use as a biosorbent (BK) for Cr (III) removal from polluted waters. The biomass was activated using H2SO4 (1.25%) and NaOH (3.25%). The characterization methods were Fourier-Transform Infrared Spectroscopy (FTIR), scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS), and Brunauer–Emmett–Teller (BET) analysis. Our results confirmed the presence of active groups on BK, such as –OH, -C=C-, -C=O, and -C-O-, with an increase of 1308.58% in specific surface area, as well as the presence of chromium on the biosorbent after adsorption process. The adsorption capacity (q) was tested in a jar test as a function of biomass granulometry, dose (BK), and the pH of the solution; the best response was 47.9 mg/g at a pH of 5.5, a biosorbent dose of 0.5 g/L, and a biosorbent size of 100 μm. The effect of pH was positive; by increasing the pH, the adsorption capacity increased. However, the effect of the biosorbent dose and size was negative, as when increasing the dose and granulometry, the adsorption capacity decreased. In addition, the kinetic process was studied, where the removal data were better fitted for the pseudo-second-order kinetic model, confirming that the adsorption mechanism was chemisorption. The adsorption capacity was 37.6 mg/g for industrial wastewater. The possibility of using kikuyu within the circular economy was demonstrated and suggests its application in continuous systems for real-world environmental conditions.
20 September 2024 in Revista Colombiana de Química
El propósito de este estudio es investigar la capacidad antibacteriana de las nanopartículas de plata (AgNPs), biosintetizadas con extractos de queñua (Polylepis racemosa), en el afluente de la Planta de Tratamiento de Aguas Residuales (PTAR) del departamento de Cusco, Perú. Los extractos de queñua se prepararon mediante maceración, utilizando como solventes agua destilada y una mezcla hidroetanólica al 50%. La biosíntesis se realizó mezclando AgNO3 0,1 M con los extractos preparados, después se estudió el efecto del pH de biosíntesis, la temperatura y el porcentaje de concentración de etanol sobre el tamaño de las AgNPs. Los resultados revelaron que las condiciones óptimas para obtener partículas con tamaños hidrodinámicos de 58,68 nm, y estables después de 11 semanas de la biosíntesis, fueron cuando se usó extracto acuoso con pH de 10 y temperatura de 20 °C. Se evaluó la actividad antibacteriana de las AgNPs en 500 mL de agua residual con una carga inicial de 33 × 106 NMP/100 mL de coliformes totales y termotolerantes, los hallazgos indicaron que las dosis de AgNPs erradicaron casi el 100% de estos contaminantes, lo que sugiere que las AgNPs son un potencial agente antibacteriano.
Given the abundance of kikuyu biomass resulting from the pruning of green areas, the aim of this study was to evaluate its use as a biosorbent (BK) for Cr (III) removal from polluted waters. The biomass was activated using H2SO4 (1.25%) and, NaOH (3.25%), and then characterized using Fourier-Transform Infrared Spectroscopy (FTIR) and, Scanning Electron Microscopy/Energy Dispersive Spectroscopy (SEM/EDS). The surface area was measured using the Brunauer-Emmett-Teller (BET) method. The adsorption process was carried out by employing a jar test, evaluating the adsorption capacity (q) as a function of biomass granulometry, dose (BK) and the pH of the solution. In addition, the kinetic process, BK regeneration and adsorption capacity on fur industry effluents were evaluated. Our results confirmed the presence of active groups on BK such as: –OH, -C=C-, -C=O, and -C-O-, with an increase of 1308.58% in specific surface area, as well as the presence of chromium. The three variables under study were significant and related in a mathematical model. Maximum adsorption capacities (qmax) of 47.9, and 37.6 mg/g were obtained when using synthetic waters and fur industry effluents, respectively. The pseudo-second-order kinetic model confirmed that the adsorption mechanism is chemisorption. Furthermore, it was possible to regenerate the BK at a pH of 3 with an adsorption capacity of 28.7 mg/g. The possibility of using kikuyu within the circular economy was demonstrated.
12 April 2024 in Ambiente, Comportamiento y Sociedad
La presente investigación tuvo como objetivo determinar el grado de degradación de amoxicilina en aguas contaminadas mediante proceso de oxidación con dióxido de cloro (ClO2). Para este proceso se estudiaron las variables pH (5, 6.5 y 8) y dosis de ClO2 (5 ,12.5 y 20 ml), en muestras de 47.20 ppm de amoxicilina y volúmenes de 500 mL. Este proceso se llevó a cabo en un equipo de prueba de jarras. Los resultados indican que las dos variables (pH y dosis de ClO2) presentan efecto importante y son significativas sobre el porcentaje de Demanda Química de Oxígeno eliminada (%DQOe). Se estableció el modelo matemático que relaciona las variables en estudio con una bondad de ajuste R2 = 99.68%. Asimismo, se logró una remoción de 77.3% a condiciones de pH 8 y dosis de ClO2 de 20 mL.
La presente investigación tiene el objetivo: describir y analizar el rendimiento académico de los estudiantes de pre grado de una universidad pública del Perú, durante los años del 2016 al 2019, mediante las calificaciones obtenidas al término de cada semestre, corresponde a un estudio cuantitativo, descriptivo y analístico. Se procesaron estadísticamente las notas obtenidas por los todos los estudiantes; cuyos resultados muestran que el rendimiento de los estudiantes es satisfactorio en un 70%, que depende de la escuela profesional y de las asignaturas. Se concluye que los estudiantes de las especialidades de ingeniería y de ciencias básicas tienen, en términos generales, menores rendimientos que los de ciencias sociales y ciencias de la salud; las asignaturas con menores rendimientos son: química, física y matemáticas.
30 September 2025 in Ambiente, Comportamiento y Sociedad
Este estudio evaluó la aplicación del proceso Fenton para la remoción de materia orgánica no biodegradable, medida como demanda química de oxígeno (DQO) en el efluente de la PTAR San Jerónimo, Cusco. Se empleó el diseño factorial Box-Behnken para determinar las concentraciones de Fe²⁺, H₂O₂ y pH que logren mayor porcentaje de remoción de DQO. La caracterización fisicoquimica del efluente mostró un pH de 7.8, DQO de 180 mg/L, DBO de 75 mg/L, aceites y grasas de 5 mg/L, sólidos suspendidos totales de 150 mg/L y una temperatura de 20 °C. Se realizaron 15 tratamientos con dos réplicas, haciendo un total de 45 pruebas. Los resultados indicaron una alta eficiencia de remoción de DQO, alcanzando un máximo de 89.0% con 60 mg/L de Fe²⁺, 600 mg/L de H₂O₂ y un pH de 3.0, lo que confirma la viabilidad del proceso Fenton como una alternativa a ser implementada en la PTAR San Jerónimo, que permita la remoción de contaminantes emergentes.